Solar Kit
BATTERY STATUS LEDS
The Battery Status LEDs (Fig. 2 ref. (5) ) indicate the level
of charge on the battery. The indication is based only on bat-
tery voltage setpoints, which provides an approximation of
the actual state of charge of the battery.
Battery Status LED indications.
LED
Indication
Battery Sta-
tus
Load-
Status
Green
Flashing
Charging
ON
Green
Slow Flashing
Trickle Charge
ON
Green
On solid
Battery Full
ON
Yellow
On solid
Battery Half
Full
ON
Red
Flashing
Battery Low
ON
Red
On solid
Battery Empty
OFF
None
No LEDS On
No Battery
OFF
Status LED (Fig 2 Ref (1) ) Error Indications
• Solar overload
Flashing Red
• High Voltage Disconnect
Flashing Red
• High Temperature Disconect
Flashing Red
• Internal Damage
Solid Red1
Battery Status LEDs (Fig 2 Ref (5) ) Error Indications
• High Voltage Disconnect
R - G Sequencing
• High Temperature Disconnect R - Y Sequencing
• Load Overload
R&G - Y Sequencing
• Self-test Error
R - Y - G Sequencing
STATUS LED
The Status LED (Fig. 2 ref. (1) ) indicates charging status
and any existing solar input error conditions. The Status LED
is on when charging during the day and off at night. The Sta-
tus LED will flash red whenever an error condition(s) exists.
Status LED indications.
Color
Indication
Operating State
None
Off (with heart-
beat¹)
Night
Green
On Solid (with
heartbeat²)
Charging
Red
Flashing
Error
Red
On Solid
Critical Error
¹ Status LED heartbeat indication flickers ON briefly every
5 seconds
² Status LED heartbeat indication flickers OFF briefly every
5 seconds
5.
SOLAR CONTROLLER LED INDICATION
6.
TROUBLESHOOTING
Note:
A solid red Status LED indicates that a critical fault has
been detected. Critical faults typically indicate that the
controller is damaged and requires service.
LED error indications can be interpreted as follows:
“R - G sequencing” means that the Red LED is on, then
the Green LED is on, then Red LED is on....
“R&G - Y sequencing” means that both the Red LED and
Green LED are on, then just the Yellow LED is on, then
Red and Green LED are on....
Solar Overload
If the solar current exceeds the maximum solar rating, the
controller will stop charging until the solar current returns
to within its operational rating.
High Voltage Disconnect
The battery voltage has exceeded the controller’s maxi-
mum regulation limit of 30.6V . The solar and load will be
disconnected until the battery voltage decreases to the
reconnect threshold of 28V.
High Temperature Disconnect
The heatsink temperature has exceeded 185 °F (85 °C)
and the solar and load is disconnected. The controller will
automatically reconnect when the heatsink cools to 176 °F
(80 °C).
Load Overcurrent
If the load current exceeds the maximum load current rat-
ing, the controller will disconnect the load.
The controller will attempt to reconnect the load two (2)
times approximately 10 seconds apart. If the overcurrent
condition remains after the first two (2) attempts, the fault
must be cleared by removing and reapplying power.
This error can also indicate a reverse polarity on the bat-
tery. Check wiring.