Automatic concealed bollards 

275 H600 and 275 H800

  

Control station

 

 

 

 

 FAAC S.p.A. Via Benini, 1 40069 Zola Predosa Bologna (Italia) tel. +39 051 61724 www.faac.it

 

 

Summary of Contents for 275 H600

Page 1: ...Automatic concealed bollards 275 H600 and 275 H800 Control station FAAC S p A Via Benini 1 40069 Zola Predosa Bologna Italia tel 39 051 61724 www faac it...

Page 2: ...ller Bollard electrical connection Technical specifications for control station Control station lay out Dip switches on control board Connection terminal boards for control boards FAAC S p A Via Benin...

Page 3: ...safety requirements of the following EEC directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendment 92 31 EEC and 93 68 EEC Additional information These products under...

Page 4: ...sed 7 Do not install the equipment in an explosive atmosphere the presence of gas or inflammable fumes is a serious danger to safety 20 Do not in any way modify the components of the FAAC CITY automat...

Page 5: ...movement the 1 st FAAC CITY is connected to the master unit the others are connected to additional slave units the enclosure dimension depends on the quantity of FAAC CITIES WALL FITTING ENCLOSURES F...

Page 6: ...Input Out 24V d c OK Out 12V d c OK Out Green Traffic Lights Out Running Out Opened down Out Solenoid Valve Out Closed up Out Bollard fix Out Bollard mobile Out Acustic Bollard Pressure Sensor Input L...

Page 7: ...rotection AUX Protection Out 24V c c OK Limit Switch Opening Input Pressure Sensor Input PF1 PF2 L3 L2 L1 Slave Slave Connection Master Slave Slave Slave Connection FAAC S p A Via Benini 1 40069 Zola...

Page 8: ...or every type of movement to be controlled must be installed 230Vac Line Optional Emergency Button 230 V Optional Induttive Detector Prearrangement N C Prearrangement N C Trasformer 100 VA Faac City C...

Page 9: ...P NO NC COM POWER 230V 2AT 5AT 1AT 2AT 2AT 2AT 1AT 55 50 20 21 46 49 42 39 38 37 36 40 43 34 33 32 35 30 29 28 25 24 23 22 26 27 31 41 48 47 44 45 53 52 51 54 19 4 5 6 8 9 7 10 13 14 12 15 16 17 18 11...

Page 10: ...5 50 20 21 46 49 42 39 38 37 36 40 43 34 33 32 35 30 29 28 25 24 23 22 26 27 31 41 48 47 44 45 53 52 51 54 19 4 5 6 8 9 7 10 13 14 12 15 16 17 18 11 3 2 1 59 57 56 58 M PR 12V 12V 0 230V A C B 2AT 5AT...

Page 11: ...re connected to the FAAC City Master equipment POWER CONNECTION MODEL 275 11 12 14 16 15 13 7 4 6 8 4 Control board terminals PR CABLE 2x1 CABLE 2x1 CABLE 4G1 CABLE 5G0 5 2 4 3 1 6 5 6G0 7 SHIELDED CA...

Page 12: ...VERSING PRESSURE SWITCH ENABLED 5 REVERSING PRESSURE SWITCH DISABLED DIP SWITCH 1 position to be defined depending on the system s use and configuration if the safety devices are not used it must be p...

Page 13: ...nals 20 and 21 to each other ON Position SAFETY DEVICES DISABLED the input for the safety devices terminals 20 21 is disabled If the FAAC CITY bollard does not rise you may temporarily disable the saf...

Page 14: ...rd and return it to its low position ON Position REVERSING PRESSURE SWITCH DISABLED the function described above is disabled If the FAAC CITY bollard does not rise or if during the rise stage the boll...

Page 15: ...nnection for flashing lighted sign 24 Vac intermittent output Terminals 20 21 22 23 connection for safety inductive detector Terminals 24 25 lowering command input Terminals 26 27 28 29 30 connection...

Page 16: ...nnection to FAAC CITY low limit switch Terminal 15 connection for FAAC CITY intermittent buzzer Terminal 16 connection for flashing light incorporated into the head of FAAC CITY Terminal 17 common con...

Page 17: ...FAAC S p A Via Benini 1 40069 Zola Predosa Bologna Italia tel 39 051 61724 www faac it...

Page 18: ...18 www faac it Distributor s Stamp The descriptions and illustrations contained in the present manual are not binding FAAC reserves the right whilst leaving the main features of the equipments unalter...