background image

Exclusions and Limitations:

a) Maintenance, control, repair or replacement of parts that have
deteriorated after normal use.
b) Damage or malfunctioning resulting from wrong installation, misuse or
use that does not agree with the technical instructions supplied, and any
defect that is not caused by a construction defect, and therefore to the
responsibility of F1 Electronica S.R.L.
c) Products installed, repaired, replaced or changed by individuals not
authorized in writing by F1 Electrónica.
d) Accidents caused by force majeure (i.e.: fire, water, electromagnetic
fields, etc.) not controlled by F1 Electrónica.

Serial Nr.:

Date of installation:

Vehicle model and brand:

Fitter Stamp:

4

ENGLISH

9

ENGLISH

[ TO BE PROVIDED TO USER ]

E

H

03

04

02

G

B

01

05

06

07

E

02

F

C

D

J

A

(-)

(+)

Connection Diagram of DELTA Electronic Change-over Switch

References for the connection diagram of DELTA electronic change-over switch

A

B

C

D

E

F

G

H

J

Rear view of DELTA change-over switch.

MAX. 5A Fuse

Pressure gauge with infrared sensor.

Connection cables to pressure gauge.

Chassis GROUND.

PETROL electrovalve (CARBURETOR mode).

Ignition coil, or ignition module, or ECU.

Gas electrovalve.

+12V under ignition swtich.

01

02

07

06

05

04

03

ORANGE cable (+12V).

BLACK cable (GROUND).

RED cable,

connection to ignition coil

negative, or ignition module signal

, or

ignition signal of the ECU, or RPM signal of
the ECU. This signal must have a minimum
amplitude of 5V.

BLUE cable.

WHITE cable.

YELLOW cable.

GREEN cable.

Summary of Contents for DELTA

Page 1: ...ica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electrónica S R L F1 Electróni...

Page 2: ...lectrical installations are welded and properly isolated THE PROPER OPERATION OF THE CHANGE OVER SWITCH DEPENDS ON FOLLOWING THE ABOVE MENTIONED INSTRUCTIONS NEVER thread the pressure gauge using your hand Use a 14mm fix wrench Direct sunlight on the pressure gauge affects its operation For example if the hood is open the indicator lights might not turn on NOTES ...

Page 3: ...osed if necessary to the purchase receipt F1 Electrónica may refuse to recognize this warranty if it is incomplete or false This warranty will only be valid if the product was in good operating conditions at the moment of purchase and its packaging intact as F1 Electrónica is the only one that may warranty its origin 3 ENGLISH 10 ENGLISH PARA ENTREGAR AL USUARIO Technical Features F1 Electrónica S...

Page 4: ...lation Vehicle model and brand Fitter Stamp 4 ENGLISH 9 ENGLISH TO BE PROVIDED TO USER E H 03 04 02 G B 01 05 06 07 E 02 F C D J A Connection Diagram of DELTA Electronic Change over Switch References for the connection diagram of DELTA electronic change over switch A B C D E F G H J Rear view of DELTA change over switch MAX 5A Fuse Pressure gauge with infrared sensor Connection cables to pressure ...

Page 5: ...Green GAS GAS pressure is indicated through 4 leds The reserve is indicated through the intermitent led Operation of DELTA Change over Switch Leds indicating GAS pressure Operation of DELTA change over switch in CARBURETOR mode GAS position of change over switch Switch over from GAS to PETROL Change over from PETROL to GAS If the vehicle s ignition is on the GAS electrovalve is opened for 3 second...

Page 6: ... exceeded This change over switch is programmed for automatic change over at 2500 RPM during deceleration for 4 cylinder vehicles with distributor The indicator must be placed in SETTING mode special operating mode as follows Place the indicator switch on the central position then turn the vehicle s ignition switch on and within the next 10 ten seconds repeat the following sequence 3 three times M...

Reviews: