TRT800A / P/N 800ATC-A-(2xx)-(3xx)
Operation and Installation
19
Document-No: 03.2114.010.71e / Revision: 2.00
3.6.2
Static Air Port
Install a silicon soft tube fitting the 5 mm static air hose at the backside of
the transponder and secure plumbing with appropriate clamps.
3.7
Wiring
3.7.1
Conductor Cross Section
Power Supply (Power, GND):
AWG20 (0,62 mm²)
Signals:
AWG22 (0,38 mm²)
The conductors must be approved for aircraft use.
3.7.2
Pin Assignment
The transponder may only be operated together with an
external memory address adaptor TRT800EMxx
Pin Signal
Remarks
Adaptor
TRT800
EMRS
Prev.
Adaptors
(2)
TRT800
EMSS EM
1
GND
-
●
●
●
2
Remote control
(1)
Input
●
3
EEPROM Signal
TRT800EMxx internal
4
EEPROM Signal
TRT800EMxx internal
5
TX RS-232
Serial Output
●
○
●
6
reserved
-
○
○
7
Remote control
(1)
Output
●
8
+UB power supply
Input
●
●
●
9
GND
-
●
●
●
10
EEPROM VCC
TRT800EMxx internal
11
EEPROM GND
TRT800EMxx internal
12
RX RS-232
Serial Input
●
○
●
13
Suppression
Input / Output
●
○
●
14
reserved
-
15
Fly-GND Switch
(3)
Input
(1)
●
○
●
Summary of Contents for TRT800A-OLED