3.3. SYSTEM 

CONNECTION 

 

 
IMPORTANT ! 

 
Ingress of foreign matter, however small, will cause serious 
damage. 
Such matter includes dust, sand, masonry debris, impurities in the 
tubes, cutting burrs or filings, welding or soldering slag and 
splatter, metal burrs and any residues from sealing and making the 
tube connections. 
 
To ensure proper installation, please note the following:

 

 

• 

To connect the unit to the process lines, remove the flanges 

and connect via flexible tubes; 

• 

Remember to protect the inlet with suitable filters; 

• 

To avoid using rigid couplings, which could induce stress and 

cause harmful vibrations; 

• 

Only remove the plugs on the ports when making the final 

connections; 

• 

Select the tube size and the couplings to minimize the 

pressure drop, in particular: 

Do not use tubing of a smaller diameter than the ports of 

the device; 

Utilise large radius bends and avoid using elbows. 

 

 
Available connection 

TF threaded flange GAS (G 1 ½”, G 2”, G 3”); 

TF threaded flange NPT (NPT 1 ½”, NPT 2”, NPT 3”); 

Sleeve MP5, MP6, MP8; 

Collector CT66, CT88, CT89; 

Adaptator for SCL V4, V5, V6 and K series 

 
 

 
3.4. ACTUATOR 

CONNECTION 

 
CAUTION! 
BEFORE UNDERTAKING ANY OPERATION ENSURE THAT 
THE UNIT IS DISCONNECTED FROM POWER SUPPLY. 
 
3.4.1. ELECTRICAL 

CONTROL 

 

WARNING 
BEFORE UNDERTAKING ANY OPERATION ENSURE THAT 
THE UNIT IS DISCONNECTED FROM THE POWER SUPPLY. 

 
The electromagnet has been selected for service in an ambient 
temperature between 0°C and +35°C at an altitude no higher than 
1000 m. 
 
Verify the identification letter engraved on the back side of the 
electromagnet. Line voltage values should be consistent with 
following chart: 
 

Identification 

word 

Voltage 

 

(V) 

Absorbed 

current 

(A) 

Activization 

ratio ED 

(%) 

24Vdc 2.26 

60 

110Vac 0.58 

60 

220Vac 0.29 

60 

 
The current drawn refers to normal operating conditions. 
Variations in the supply voltage up to ± 5% are acceptable. 
 
 

IMPORTANT !

 

The magnet activation time (“ED”) is calculated as the time the 
magnet is energized as a per cent of total cycle time and 
should be equal to a maximum of 60% as indicated in table. 
Exceeding this value could overheat the magnet and result in 
premature failure. The maximum activation time is 5 minutes.

 

 

The electromagnets come supplied with appropriate connections 
for quick installation. 

 
 

The connections provided offer complete protection from water 
ingress according to the norm DIN 40050 (Class IP65 level of 
protection) when correctly installed using appropriate connecting 
screws and sealing gaskets. In addition, units conform to 
VDE0110-1/89, working voltage up to 300v,  working level C 
regarding class of insulation. 

 

In order to wire the electromagnets, please use the following 
instructions: 

  

• 

Remove the screws located on the upper part of the 

connection and extract the last one from its support 

• 

Remove the terminal contacts from the protective cap on the 

connector by use of a screwdriver.;these two components 
have a release joint 

• 

Complete the wiring following the diagram on the terminal 

connections by the use of locking  screws 

• 

Reassemble in reverse order (do not forget the gaskets) 

 
N.B.  The terminal connectors and the external protection of the 
connectors are able to be put in 4 different orientations. Select the 
one most suitable for your installation.

 

 

IMPORTANT !

 

CHECK TO ENSURE PROPER GROUNDING 
THE ENTIRE GUARANTEE SHALL CEASE TO APPLY WHEN 
INADEQUATE PROTECTION IS PROVIDED. 

 

 

3.4.2. PNEUMATIC 

CONTROL 

 
ATTENTION ! 

Before commissioning in installation, make sure the air cylinders 
are not under pressure.

 

 

The operating characteristics for the pneumatic actuators are 
described in the following table: 

 

Pneumatic control 

Thrust air cylindrer 

Double effect 

Max pressure 

10 Bar 

Air consumption 

0,02 litres/cycle 

Operating temperature 

-5 °C ~ +70 °C 

Fluid 

Filtered Air and  preferably oiled 

Connexion G 

1/8” 

 

Use a 1/8” nipple in the appropriate receptacle of the pneumatic 
solenoid. 

 

 

4. 

OPERATION

 

 

4.1. PRELIMINARY 

CONTROLS

 

 

Before commissioning, please ensure the following: 
  

• 

Should the unit need to be stored for a long period of time 

before installation, ensure it is kept in a dry environment and 
inspect prior to installation. 

• 

Check that there are no impurities that could obstruct the seal 

between the shutter and body. 

• 

Ensure that all safety protectors have been properly installed. 

 

 
4.2. START-UP 
 

The VS6 / VS8 flow converters do not require any additional 
controls.  The 2 possible positions of the shutter are fixed by run 
length the shutter is not able to be put in an intermediate / half-way 
position. 
 
A higher-than-allowed differential pressure on the actuator could 
cause a lack of charge in the cylinder due to misalignment of the 
shutter and seal rings.

 

 

 
 

GB - 12/13

Summary of Contents for VS6

Page 1: ...ONVERTING DEVICES USE INSTRUCTIONS GB LEGGERE ATTENTAMENTE TUTTE LE ISTRUZIONI E CONSERVARLE I PLEASE READ CAREFULLY ALL INSTRUCTIONS AND KEEP THEM FOR FUTURE REFERENCE GB SN 2116 0 F P Z effepizeta s r l Via F lli Cervi 16 18 20049 Concorezzo MI ITALIA Tel 39 039 604 1820 Fax 39 039 604 1296 www fpz com ...

Page 2: ... prima che la macchina in cui sarà incorporato sia dichiarata conforme con le citate Direttive 2 Sottoposto a collaudo funzionale è risultato conforme alle caratteristiche richieste 1 Device conforms to MACHINERY DIRECTIVE CE 98 37 EMC DIRECTIVE CE 89 336 as ammended by the CE Directives 92 31 and 93 68 LOW VOLTAGE DIRECTIVE CE 73 23 as ammended by the CE Directive 93 68 Nevertheless it is forbidd...

Page 3: ... Spring 560 Grano Grub screw 562 Spina cilindrica Dowel pin 901 Vite Screw 902 Vite Screw 903 Vite Screw 904 Vite Screw 905 Vite Screw 937 Bronzina Bushing 938 Anello sostegno Supporting ring 950 Raccordo Connector ESECUZIONE EXECUTION O ESECUZIONE EXECUTION P Comando elettrico Electrical control Comando pneumatico Pneumatic control 363 555 562 937 902 165 938 420 421 106 380 904 903 550 381 905 5...

Page 4: ...3 2 INSTALLATION SKETCHES 11 3 2 1 PRESSURE SYSTEM WITH ELECTRIC CONTROL 12 3 2 2 VACUUM SYSTEM WITH ELECTRIC CONTROL 12 3 2 3 PRESSURE VACUUM SYSTEM WITH PNEUMATIC CONTROL 12 3 3 SYSTEM CONNECTION 12 3 4 ACTUATOR CONNECTION 12 3 4 1 ELECTRIC CONTROL 12 3 4 2 PNEUMATIC CONTROL 12 4 OPERATION 12 4 1 PRELIMINARY CHECKS 12 4 2 START UP 12 4 3 PERIODIC CHECKS 13 5 MAINTENANCE 13 5 1 INTERNAL CLEANING ...

Page 5: ... in service before the machines of which they are a part are declared to conform to the CE Machinery Directive The user must be aware that in operation there can be an increase in unit operating temperature there is small loss of the fluid handled the level of noise may be unacceptable in certain applications CAUTION Before undertaking any operation ensure that the unit is disconnected from power ...

Page 6: ...ION TO THE BLOWER CONNECTION TO THE BLOWER ELECTROMAGNET ACTIVATED CONNECTION TO THE LINE ELECTROMAGNET NOT ACTIVATED CONNECTION TO THE LINE CONNECTION TO THE BLOWER CONNECTION TO THE BLOWER ELECTROMAGNET ACTIVATED CONNECTION TO THE LINE PNEUMATIC ACTUATOR POSITION 1 CONNECTION TO THE LINE CONNECTION TO THE BLOWER CONNECTION TO THE LINE PNEUMATIC ACTUATOR POSITION 2 Compressed air inlet Compressed...

Page 7: ...quick installation The connections provided offer complete protection from water ingress according to the norm DIN 40050 Class IP65 level of protection when correctly installed using appropriate connecting screws and sealing gaskets In addition units conform to VDE0110 1 89 working voltage up to 300v working level C regarding class of insulation In order to wire the electromagnets please use the f...

Page 8: ...mance variations misalignment of the shutter with the sealing rings resulting in pressure loss within the system Internal cleaning should be done routinely particuliarly in dirty dusty environments The flow converter does not necessarily have to be removed from the system for internal cleaning Referrring to page 3 use the following instructions Disconnect the actuators Disconnect the ports Clean t...

Reviews: