background image

 

1. DEVICE 

DESCRIPTION 

 
1.1. 

OPERATING PRINCIPLE AND CONSTRUCTION 

 

The device is actuated by means of a horizontal sliding selector 
which enables switching of the ports within approximately 0.10 sec. 
It is therefore possible to change flow direction or to switch the flow 
path, according to the type of installation. 
The device is an all aluminum alloy construction. It is not subject to 
contacts and interferences between the selector and device body. 
The selector acts on special flexible teflon segments which ensure 
efficient sealing between the flow chambers, and is returned and 
kept in the basic position by means of a coil spring. 
The device can be operated either electrically or pneumatically. 

 
 

2. GENERAL 

INSTRUCTIONS 

 
2.1. SAFETY 

RULES 

 
CAUTION! 

The flow converting devices ‘VS’ have been 
designed and manufactured for use in an industrial 
environment, operated by qualified personnel and 
as a unit to be incorporated in a machine, which 
conforms to the CE Machinery Directive. 
 
The flow converting devices ‘VS’, like all machinery 
and equipment with live and moving parts, can be 
a source of serious hazards unless properly used 
and protected. 
 
 
The user must ensure that: 
 
All handling, assembly, installation, connection, 
maintenance and repair operations are undertaken 
by qualified personnel. Such people who by their 
background, training and experience as well as 
through their knowledge of statutory regulations, 
legislation, safety measures and operating 
conditions are able to carry out any necessary 
steps avoiding all possible risks to health and 
damage. 

 
Such personnel should have received all the instructions and 
information, including any local legislation, and will follow this 
information during the performance of any operation. 
 
It shall be forbidden for unqualified personnel to carry out any 
operation, even indirectly, on the machines and equipment. 
 
During the installation, all the prescribed working conditions, 
including any possible local requirements, shall be observed. 
 
Additionally it is forbidden to put the unit in service before the 
machines of which they are a part are declared to conform to 
the CE Machinery Directive. 
 
The user must be aware that in operation: 
 

• 

there can be an increase in unit operating temperature; 

• 

there is small loss of the fluid handled; 

• 

the level of noise may be unacceptable in certain 
applications. 

 
 
CAUTION! 
Before undertaking any operation ensure that the unit is 
disconnected from power supply. 
 
 
 
 

 
 
2.2. 

FIELD USE AND WORKING CONDITIONS 

 
The flow converting devices ‘VS’ are designed for the continuous 
movement of air or non-explosive, non-hazardous and non-
flammable gases and for service in non-explosive environments. 
 
Devices are designed and manufactured to flow converting in low 
pressure / vacuum applications. They are for use specifically on 
low pressure blowers and vacuum pumps only. 
 
Solid particles, however small, including dirt can cause serious 
damage; therefore it is essential that such substances should be 
removed from the gas by suitable filters upstream of the inlet. 
 
There is small loss of the fluid handled. 

 

 
Pressure loss through the converter, as a function of flow, is 
indicated on graph below:

 

 
 
 
 
.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
2.3. 

STORAGE AND SHIPPING 

 

Store the unit in a dry place, preferably in original packaging. 
Do not remove the protection plugs from the ports. 
Avoid stacking anything on top of the packaging. 
 
Handle the devices with care and avoid sudden impacts. 
 

When handling devices (lifting, moving, in transit, storing) 
appropriate procedures need to be used. This work should be 
organized in a safe / secure environment, minimizing the risk of 
any possible mishap. For example: 

• 

ensure staff is adequately trained; 

• 

use secure / stable mounting/support structures; 

• 

wear suitable workclothes and individual protection 
devices;

 

 
 

3. INSTALLATION 

 
3.1. LAY-OUT 

 
It is important that the unit is installed in a well-ventilated 
environment where the temperature does not exceed 40°C. 
If outside, protect the unit from direct sunlight and avoid the 
possibility of water collecting in the external crevices. 
 
Please refer to attached SI1787 for unit dimensions

 

 

 
 
 
 
 
 

      0            20         40          60          80        100       120

     0                     0,5                   1,0                  1,5

 

mbar

psig

 

 

VS 6 

m

3

/h

cfm

50

100

200

300

400

600

800

1000

1400

0

50

100

200

300

400

500

600

800

VS 8 

Pressure loss per port 

(vacuum / pressure) 

0

GB - 10/13

Summary of Contents for VS6

Page 1: ...ONVERTING DEVICES USE INSTRUCTIONS GB LEGGERE ATTENTAMENTE TUTTE LE ISTRUZIONI E CONSERVARLE I PLEASE READ CAREFULLY ALL INSTRUCTIONS AND KEEP THEM FOR FUTURE REFERENCE GB SN 2116 0 F P Z effepizeta s r l Via F lli Cervi 16 18 20049 Concorezzo MI ITALIA Tel 39 039 604 1820 Fax 39 039 604 1296 www fpz com ...

Page 2: ... prima che la macchina in cui sarà incorporato sia dichiarata conforme con le citate Direttive 2 Sottoposto a collaudo funzionale è risultato conforme alle caratteristiche richieste 1 Device conforms to MACHINERY DIRECTIVE CE 98 37 EMC DIRECTIVE CE 89 336 as ammended by the CE Directives 92 31 and 93 68 LOW VOLTAGE DIRECTIVE CE 73 23 as ammended by the CE Directive 93 68 Nevertheless it is forbidd...

Page 3: ... Spring 560 Grano Grub screw 562 Spina cilindrica Dowel pin 901 Vite Screw 902 Vite Screw 903 Vite Screw 904 Vite Screw 905 Vite Screw 937 Bronzina Bushing 938 Anello sostegno Supporting ring 950 Raccordo Connector ESECUZIONE EXECUTION O ESECUZIONE EXECUTION P Comando elettrico Electrical control Comando pneumatico Pneumatic control 363 555 562 937 902 165 938 420 421 106 380 904 903 550 381 905 5...

Page 4: ...3 2 INSTALLATION SKETCHES 11 3 2 1 PRESSURE SYSTEM WITH ELECTRIC CONTROL 12 3 2 2 VACUUM SYSTEM WITH ELECTRIC CONTROL 12 3 2 3 PRESSURE VACUUM SYSTEM WITH PNEUMATIC CONTROL 12 3 3 SYSTEM CONNECTION 12 3 4 ACTUATOR CONNECTION 12 3 4 1 ELECTRIC CONTROL 12 3 4 2 PNEUMATIC CONTROL 12 4 OPERATION 12 4 1 PRELIMINARY CHECKS 12 4 2 START UP 12 4 3 PERIODIC CHECKS 13 5 MAINTENANCE 13 5 1 INTERNAL CLEANING ...

Page 5: ... in service before the machines of which they are a part are declared to conform to the CE Machinery Directive The user must be aware that in operation there can be an increase in unit operating temperature there is small loss of the fluid handled the level of noise may be unacceptable in certain applications CAUTION Before undertaking any operation ensure that the unit is disconnected from power ...

Page 6: ...ION TO THE BLOWER CONNECTION TO THE BLOWER ELECTROMAGNET ACTIVATED CONNECTION TO THE LINE ELECTROMAGNET NOT ACTIVATED CONNECTION TO THE LINE CONNECTION TO THE BLOWER CONNECTION TO THE BLOWER ELECTROMAGNET ACTIVATED CONNECTION TO THE LINE PNEUMATIC ACTUATOR POSITION 1 CONNECTION TO THE LINE CONNECTION TO THE BLOWER CONNECTION TO THE LINE PNEUMATIC ACTUATOR POSITION 2 Compressed air inlet Compressed...

Page 7: ...quick installation The connections provided offer complete protection from water ingress according to the norm DIN 40050 Class IP65 level of protection when correctly installed using appropriate connecting screws and sealing gaskets In addition units conform to VDE0110 1 89 working voltage up to 300v working level C regarding class of insulation In order to wire the electromagnets please use the f...

Page 8: ...mance variations misalignment of the shutter with the sealing rings resulting in pressure loss within the system Internal cleaning should be done routinely particuliarly in dirty dusty environments The flow converter does not necessarily have to be removed from the system for internal cleaning Referrring to page 3 use the following instructions Disconnect the actuators Disconnect the ports Clean t...

Reviews: