EZPull RXP-02 Sporting clays Receiver Setup Manual
Connecting the Receiver to the Trap
The RXP02 is a remote switching device designed for use with
12VDC Sporting Clays trap machines.
WARNING: DO NOT CONNECT THE RECEIVER TO THE
TRAP MACHINE BEFORE GOING THROUGH THE
FOLLOWING PROCEDURE!
1.
Determine if your trap uses “Negative” or “Positive” release:
1.1.
If applying the “Switch” line to Ground (Battery -),
releases a target, it is a “Negative” release. If applying
the “Switch” line to the +12V releases a target, it is a
“Positive” release.
1.2.
You can also measure the voltage on the “Switch” line in
reference to Ground (BAT-). If the voltage on this line is
approximately the battery voltage, it is a “Negative”
release trap.
WARNING: Do not exceed the maximum ratings!
* Maximum supply voltage 15VDC
* Maximum Trap switch current < 2Amp
* Maximum DC Trap switch < 30VDC
* Maximum AC Trap switch < 250VAC
2.
Wiring the RXP02 4 wire cable - Connect the cable to a
plug suitable for your trap machine according to table below:
Wire
Color
Connect to
RED +12VDC
BLACK GROUND
(-)
BLUE
Trap Switch N/O (Trigger)
Trap Switch COM
For Positive release connect together with
RED
YELLOW
For Negative release connect together with BLACK
3.
You can now connect the RXP02 receiver to the trap machine.
A Blue LED should glow indicating the receiver is ON.
Mounting the Receiver:
1.
The receiver must be mounted vertically with the cable going
towards the ground.
2.
For optimal performance, the receiver should be mounted a
few feet above the ground and a few feet away from the
Trap, preferably with a “line of sight” to the transmitter.
3.
The SunGuard Step-In Post 3⁄8" 4 ft from Kencove
http://www.kencove.com/fence/FibPosts_detail_F38
is a low cost and effective mounting solution. Use
Zip Ties to attach the receiver.