21
Troubleshooting
No. of
blinks
Explanation
Solution
ON
No response on motor
lost connection on 5V wire to motor , check
connectors at front fork
2
Brake lever cut off in
contact
check brake lever spring, brake levers should
return to position (applicable with electric cut-off
levers)
3
Brake lever cut off in
contact
check wiring connection, inspect for damage to
the battery level gauge
4
Throttle not in position
check if throttle spring is faulty
5
Throttle failure
signal wire to throttle shorted
5V+ signal wire to throttle shorted
Moisture penetration / leave it to dry
Check throttle connections and cable, or replace
6
low voltage
Activated when voltage drops below 30.5 V .This
continue to blink and will stop when voltage
recovers to 34V, Or when the main switch is pow-
ered off. Battery charging
7
excessively high voltage
Battery voltage is above 44 V./ do not use battery
that is not supplied by eZee, contact your eZee
dealer
8
Hall sensor in motor
faulty
One or more hall sensor disconnected or faulty.
Check connector at the front fork. If connector
is OK, contact your eZee dealer
9
Supply 3 phase wire
Check phase wires at the front fork. Contact your
eZee dealer
10
Controller overheating
Motor continue to function but the amps directed
will be lessened to reduce the load and cool
controller
Summary of Contents for quando