The microprocessor 

advanced intelligence system

 analyzes and automatically adjusts the parameters 

of the internal systems according to ambient air temperature, water pressure, gas flow, and 
incoming water temperature. By using a high-precision and reliable water flow sensor, the user-
selected pre-set gives consistent water temperature for worry-free operation.   

The gas control valve is controlled by a micro-processor which instantly calculates and controls the 
gas supply which saves on consumption and works in unison with the speed of the fan motor for 
proper combustion mixture and maximum efficiency. With this forced-air system the effects and 
efficiencies of the heat exchanger is much greater than the models that are non-fan forced. 

This model features a low water pressure start-up for use in areas where there is lower pressure. 

Memory system restarts the heater in the previously selected settings.  

Multi-function self diagnosis featuring flame-out protection, exhaust pressure self diagnosis, 
overheating protection, combustion mixture, and anti-freeze protection. 

INSTALLATION REQUIREMENTS 

Before installation, contact your local gas company and/or a qualified installer for a proper 
installation. Installation by unqualified personnel is forbidden by most local codes and is dangerous. 

*We hold no liability expressed or implied for damages of any kind, injury, or death caused directly or 
indirectly by errors in installation, improper or unsafe use, or installations done by those persons not 
qualified to do so. 

 

Mount the heater in a location that is outdoors in a well ventilated area such as an open 
yard. 

 

To avoid exhaust gasses from entering into the dwelling, the heater must be located a safe 
distance from any window or door opening.  (Minimum of five feet in every direction.) 

 

This water heater CANNOT BE INSTALLED INDOORS for any reason. 

 

Always select a mounting area that is well clear of humans or animals to protect life and 
health. Keep in mind that even though this device is very quiet, it should be considered that 
any sound it produces will not disturb others. 

 

No flammables or other devices should be near this heater. DO NOT ATTEMPT to install a 
vent hood or exhaust fan above this heater. IT IS NOT FOR INDOOR USE! Do not modify this 
heater in any way! 

 

Always plug into only a three prong outlet that is properly wired and grounded. NEVER USE 
an extension cord to connect the power supply. Ground-fault interrupted waterproof 
exterior types are best. 

 

Do not tilt the heater in any way. It must be installed upright at all times. 

 

The heater must be securely mounted with screws. 

 

Gas connections must be up to local code as per type of gas and applications. 

Summary of Contents for EZ OUTDOOR

Page 1: ...5 x 5 5 Water pressure operational range PSI 35 100 PSI Thermal efficiency rating 88 Gas type rated gas pressure Pa PSI WCI LPG 2800 0 46 11 NG 2000 0 29 8 Voltage V AC110V 60HZ Shipping carton dimens...

Page 2: ...d Air Pressure and Downdraft Detection 7 Very Low Water Pressure start up 8 AI Intelligent Memory function 9 Self adjusting fan motor 10 Twelve safety precaution protection systems All specifications...

Page 3: ...athing showering hand washing clothes washing and other washing duties Drinking note As with ALL water heaters of any design it is not advisable to drink water directly from this device unless the wat...

Page 4: ...personnel is forbidden by most local codes and is dangerous We hold no liability expressed or implied for damages of any kind injury or death caused directly or indirectly by errors in installation i...

Page 5: ...ON INSTRUCTIONS Install the control panel inside the building Mount it in an easy to use location The supplied 30 foot long control cable has a metal plug in which attaches to the bottom of the heater...

Page 6: ...periods such as vacation it is best to turn off the button on the controller This way if a pipe were to burst the heater would not turn on NOTES The water temperature may be slightly lower than the s...

Page 7: ...rained disconnected and placed indoors for safe keeping This is the type of thing that can disappear from the lake home during long periods without use and will last longer if protected from harsh wea...

Page 8: ...ENANCE Check gas and water lines for leaks often Clean the inlet water line filter If there has been a smoking condition due to a poor burn the unit should be cleaned inside by a professional technici...

Page 9: ...equate water supply insufficient air supply too high wind speed or pressure heat exchanger clogged water control unit failure no electrical power to unit short circuit Abnormal noise during ignition T...

Page 10: ...9 CELSIUS TO FAHRENHEIT CONVERSION CHART www eztankless com All specifications are subject to change without notice...

Reviews: