background image

Model  

EZ010HC  
EZ017HC  
EZ025HC

Recommended Amount

30- 40 kg dry or 38 liters liquid
60 - 80 kg dry or 66 liters liquid
90 -120 kg dry or 95 liters liquid

If you have a High Capacity Funnel Fill System

, put the funnel in the fill valve.  

Disconnect one of the shut off valves from the cap and connect it to the tubing on
the funnel.

After filling:

Close the fill valve, the shut off valve and the drain/fill valve. Disconnect the shut  
off valve from the funnel and connect it to tank cap. Remove the fill funnel and

Fill Tank With Fertilizer

Step 7 - Fill tank with fertiliser. (For detailed instructions for refilling the  
system, please see the Quick Refill Guides.)

The EZ-FLO system can be filled with any liquid or water soluble fertiliser.

Before filling:

Make sure the shut off valves are off. Open the fill valve on top of the tank and  
make sure the drain valve on the bottom of the tank is closed.

If you do not have a High Capacity Funnel Fill System

, pour fertiliser  

directly into tank through the fill valve, adding water periodically by opening one
shut off valve. 

When the tank is full of fertiliser, top it off with water until all

air is gone from the tank.

Open the shut off valve and pour the fertiliser into the funnel  

until tank is full of liquid, all air must be out of tank

5

turn both shut off valves to the on position.

© 2 0 1 7 , EZ- FLO Fe r t ilizin g Sy st e m s

Slooww 

11 22 

FFastt

F

Fe

errttiilliiz

ze

err

W atate

err

Outt

IInn

G

GR

RE

EEN

B

BL

LUE

FILL  

VALVE

HIGH CAPACITY  

FUNNEL FILL SYSTEM

AIR VENT

DRAIN  
VALVE

SHUT OFF  

VALVE

SHUT OFF  

VALVE

AIR

E

AIR

*Note that 

HCV model 

numbers equate to capacity in liters

Tank Size

*

38 lit er s
66 lit er s
95 lit er s

Summary of Contents for EZ010HC

Page 1: ...25 kPa Follow all local plumbing codes Use only with non hazardous products Minimize exposure to direct sunlight to maximize service life Protect against impact from foreign objects All EZ FLO systems have been specifically designed and engineered to be installed by a professional irrigation or landscape contractor Improper installation or use could cause risk of water contamination due to back fl...

Page 2: ...o Fertiliser Out connection incap Agitation Fitting Part AGT Agitation tubeattaches to Water Inconnection in cap if using liquids remove and replace with adaptersupplied LARGE O RING Part LOR BLUE CONNECTOR NUT Part CNB GREEN CONNECTOR NUT Part CNG TANK ratio CAP Part CAPHP or MBT 2017 1 25 meter 6mm black tubing part BT5 2 Shut Off Valves Part SOV with 2 washers ReliefValve on PVC series only 1 F...

Page 3: ... be made after an approved back flow prevention device It is preferable to have the tank cap above the installation point in the sprinkler line if possible but it is not required for efficient operation The connection can be made either vertically or horizontally in the sprinkler main line INSTALL BALL VALVECOUPLING IN THIS AREA 2 To back yard TOP VIEW SPRINKLER VALVE Step 2 Shut off water by clos...

Page 4: ...the coupling Step 4 Glue the coupling into the line Step 5 Attach tubing to the coupling CUT PIPE GLUE IN COUPLING WITH FLOW ARROW POINTING IN THE DIRECTION OF THE WATER FLOW FLOW ATTACH BLACK TUBI NG TO BLUE FI TTI NG CLEAR TUBI NG TO GREEN FI TTI NG AND SECURE W I TH TUBI NG CLAMPS FLOW GREEN BLUE GREEN BLUE CUTOUT LENGTH Ball Valve Coupling Adjustable LowFlow 3 2018 EZ FLOTM Fertilizing Systems...

Page 5: ...ct the green connector nut to the fertiliser out connection on the cap Turn the water on to the system Connect tubing to cap 1 Shut off valves in the off position 2 Turn water on at back flow preventer 3 Connect blue connector to water in connection on cap 4 Connect green connector to fertilizer out connection on cap 2 0 1 8 EZ FLO Fertilizing System s 4 In Out FFeirtl l i i zzer O u u t t GREEN F...

Page 6: ...fore filling Make sure the shut off valves are off Open the fill valve on top of the tank and make sure the drain valve on the bottom of the tank is closed If you do not have a High Capacity Funnel Fill System pour fertiliser directly into tank through the fill valve adding water periodically by opening one shut off valve When the tank is full of fertiliser top it off with water until all air is g...

Page 7: ...rove the condition of a landscape in poor condition The unit will empty more quickly and can be refilled more often Fast Setting is used for periodic fertilisation The unit will empty more quickly and can be refilled more often Setting Ratio gram s of fertiliser per liter Slow 15 000 1 0 07 1 8 000 1 0 13 2 2 000 1 0 5 Fast 400 1 2 5 2 0 1 8 EZ FLO Fertilizing System s Fertiliser Out Green Water I...

Page 8: ...e tank cap 3 Screw blue and green connectors onto bypass fitting 4 Drain tank and return it to the valve box or store in garage If you need assistance with the installation or operation of your system or have further questions please visit our web site at w w w ezflo com or call EZ FLO on 0 7 4 7 7 8 0 1 8 0 For warranty provisions for this unit please refer to our website under resources Fertilis...

Reviews: