System Installation

Typical installation

The system is normally installed in a valve box, connected to the main line of the irrigation  
system after the back flow preventer and before the sprinkler valves. One unit will feed both  
drip and sprinkler zones that are downstream from the connection point.

Back Flow  
Preventer

Ball Valve

Coupling
Connection

To drip emitters

To sprinklers

Water Flow

To subsurface

Valve Box

EZ-FLO Unit  

Valve Box

Step 1

- Locate the installation point.

Connection must be made after an approved back flow prevention device. It is preferable to  
have the tank cap above the installation point in the sprinkler line if possible but it is not  
required for efficient operation. The connection can be made either vertically or horizontally  
in the sprinkler main line.

INSTALL BALL VALVE COUPLING  

IN THIS AREA

2

To 
b

ack

ya
rd

TOP VIEW

SPRINKLER  

VALVE

Step 2

- Shut off water by closing a valve 

at the back flow preventer or in the main  

line upstream from the connection point. Relieve the pressure from the line at the exhaust  
valve on the back flow preventer or by manually opening a sprinkler valve.

SHUT OFF  

WATER

RELIEVE  

PRESSURE

OFF

© 2 0 1 8 , EZ- FLO Fe r t ilizin g Sy st e m s

Summary of Contents for EZ010HC

Page 1: ...25 kPa Follow all local plumbing codes Use only with non hazardous products Minimize exposure to direct sunlight to maximize service life Protect against impact from foreign objects All EZ FLO systems have been specifically designed and engineered to be installed by a professional irrigation or landscape contractor Improper installation or use could cause risk of water contamination due to back fl...

Page 2: ...o Fertiliser Out connection incap Agitation Fitting Part AGT Agitation tubeattaches to Water Inconnection in cap if using liquids remove and replace with adaptersupplied LARGE O RING Part LOR BLUE CONNECTOR NUT Part CNB GREEN CONNECTOR NUT Part CNG TANK ratio CAP Part CAPHP or MBT 2017 1 25 meter 6mm black tubing part BT5 2 Shut Off Valves Part SOV with 2 washers ReliefValve on PVC series only 1 F...

Page 3: ... be made after an approved back flow prevention device It is preferable to have the tank cap above the installation point in the sprinkler line if possible but it is not required for efficient operation The connection can be made either vertically or horizontally in the sprinkler main line INSTALL BALL VALVECOUPLING IN THIS AREA 2 To back yard TOP VIEW SPRINKLER VALVE Step 2 Shut off water by clos...

Page 4: ...the coupling Step 4 Glue the coupling into the line Step 5 Attach tubing to the coupling CUT PIPE GLUE IN COUPLING WITH FLOW ARROW POINTING IN THE DIRECTION OF THE WATER FLOW FLOW ATTACH BLACK TUBI NG TO BLUE FI TTI NG CLEAR TUBI NG TO GREEN FI TTI NG AND SECURE W I TH TUBI NG CLAMPS FLOW GREEN BLUE GREEN BLUE CUTOUT LENGTH Ball Valve Coupling Adjustable LowFlow 3 2018 EZ FLOTM Fertilizing Systems...

Page 5: ...ct the green connector nut to the fertiliser out connection on the cap Turn the water on to the system Connect tubing to cap 1 Shut off valves in the off position 2 Turn water on at back flow preventer 3 Connect blue connector to water in connection on cap 4 Connect green connector to fertilizer out connection on cap 2 0 1 8 EZ FLO Fertilizing System s 4 In Out FFeirtl l i i zzer O u u t t GREEN F...

Page 6: ...fore filling Make sure the shut off valves are off Open the fill valve on top of the tank and make sure the drain valve on the bottom of the tank is closed If you do not have a High Capacity Funnel Fill System pour fertiliser directly into tank through the fill valve adding water periodically by opening one shut off valve When the tank is full of fertiliser top it off with water until all air is g...

Page 7: ...rove the condition of a landscape in poor condition The unit will empty more quickly and can be refilled more often Fast Setting is used for periodic fertilisation The unit will empty more quickly and can be refilled more often Setting Ratio gram s of fertiliser per liter Slow 15 000 1 0 07 1 8 000 1 0 13 2 2 000 1 0 5 Fast 400 1 2 5 2 0 1 8 EZ FLO Fertilizing System s Fertiliser Out Green Water I...

Page 8: ...e tank cap 3 Screw blue and green connectors onto bypass fitting 4 Drain tank and return it to the valve box or store in garage If you need assistance with the installation or operation of your system or have further questions please visit our web site at w w w ezflo com or call EZ FLO on 0 7 4 7 7 8 0 1 8 0 For warranty provisions for this unit please refer to our website under resources Fertilis...