Walk In Tub
Installation and Operating Instructions
®
www.ezable.com
877-392-2531
adjustments to the crews. Re-measure after each
adjustment. Once the opening is at 20.25” tighten the
LOWER nut back up.
8.
Once the door opening has been properly set to
20.25”, the stabilizing bar’s .375” nuts (8 total) can
be tightened.
FIGURES 17 & 18
FIGURE 14
Frame Adjusting Screws
FIGURE 15
FIGURE 16
Upper Nut
Upper Nut
Lower Nut
Lower Nut
Stabilizing Rods
(2 rods)
Stabilizing Rod Nuts
(4 per each rod)
FIGURE 18
FIGURE 17
SerenityNow
Page 7 of 9
Summary of Contents for SerenityNow