Intelligent pulse battery charger AP-17
CHARGING PROGRAMS
There are 3 jumpers inside the device, which are used to set charging programme.
To do that, we first unplug device from socket. On bottom of the case, we unscrew 4
bolts and remove cover. There are 3 jumpers on the smaller power circuit board, which
we use for setting charging programme and device operation mode. Charger has 4
charging programmes: universal programme
UNI
, programme for wet hermetic start
battery
CaCaWET
, programme for
AGM
battery and programme for
GEL
battery.
Setting the charging mode enables device to operate either as
charger
(it charges
battery until it is full) or as a battery
buffer
(battery is constantly connected to charger
and is providing power for load, such as light, refrigerator in case of caravan, boat or
sailboat).
Mode
JP3
JP2
JP1
Type of battery
Charger
Conect (1)
Conect (1)
Conect (1)
UNI
(Universal)
Charger
Conect (1)
Conect (1)
Disconect (0)
CaCaWET
Charger
Conect (1)
Disconect (0)
Conect (1)
AGM
Charger
Conect (1)
Disconect (0)
Disconect (0)
GEL
Buffer
Disconect (0)
Conect (1)
Conect (1)
UNI
(Universal)
Buffer
Disconect (0)
Conect (1)
Disconect (0)
CaCaWET
Buffer
Disconect (0)
Disconect (0)
Conect (1)
AGM
Buffer
Disconect (0)
Disconect (0)
Disconect (0)
GEL
Illustration of jumpers in the battery
charge controller.
With the proper jumpers adjustment, we
select the filling profile and the charging
method
»charger«
or as a
»buffer«
4