background image

 

 

Installation Instructions 

 

 

Aphos

 CM Luminaires 

 

 

        

                                                                                                                                                                             

 

 

 
 

EQS3423 REV:  D 

 
 
INSTALLATION INSTRUCTIONS:

 

 

Read the instructions completely before starting 
installation. 

 

Installation shall be done in compliance with the 
National Electric and Building Codes, as well as with 
State and Local Code requirements in effect at the 
time of installation. The local inspector has final 
jurisdiction on any installation. 

 

Ensure that supply power is off 

 

Luminaire installation and service shall be executed 
by qualified personnel only. 

 

Unpack the luminaire and inspect for damage in 
shipment. If it is damaged in any way, do not install. 

 

Locate the manufacturer’s labels. Note all 
specifications and warnings on the labels. Enter serial 
number and installation date in area provided. Retain 
this information and Instructions for future reference. 

 

Ensure that junction box is appropriately sized and 
sufficient to mount and support this luminaire. Refer 
to Specifications given above for weight and 
approximate dimensions. 

 

Locate the power supply leads and route through the 
center hole of the J Box Bracket. Attach the J Box 
Bracket to the junction box, in a manner sufficient for 
permanent mounting, pursuant to all local, state and 
national codes. The provided holes in the J Box 
Bracket will accept (4) 8-32 or M4-0.7 screws. 

 

Place the luminaire onto J Box Bracket by inserting 
the square flange side of the bracket through the slot 
opening in the luminaire bracket which has no holes 
next to the slot opening. Allow the luminaire to hang 
in this position while electrical connections are made. 

 

If the luminaire is equipped with E1 wiring (Wet 
Location) connect the black

 

lead to line/Phase 1, the 

white lead to white/Phase 2, and the green lead to 
ground. (See Figure 4 on sheet 3). If the luminaire is 
equipped with E2 (Damp-Dry location) make 
electrical connections to Terminal Block, matching 
wire connections as described above. 

 

Complete the installation by swinging the luminaire 
up until the luminaire bracket meets and snaps 
securely onto J Box Bracket. Insert screws (provided) 
to secure luminaire bracket to J Box Bracket. 

 

Make the electrical connections (Figure 2) if supply 
voltage is 120 to 277 VAC or (Figure 3) if supply 
voltage is 347 / 480VAC and using 480V to 277V 
Step-Down Remote Mounted Autotransformer.  

 

 
 

 
 
 
Luminaire Serial #:_____________ 
Date of 
Installation:_____________Location:_____________ 

 

           J Box Bracket 

                            

Luminaire Bracket 
 

 

Assembled Luminaire 
 

 

        Figure 2 

 
 
 
 
 
 
 
 
 

 

347-480V wiring 

Reviews: