EYC FTS34 Operation Manual Download Page 3

 

www.eyc-tech.com

 

 

 

2

 

 

Thermo Air Velocity Transmitter

 

 

Air Velocity

 

I.

 

Security considerations 

Please read this Specification carefully, prior to use of this, and keep the manual properly, 
for timely reference. 
Solemn Statement: 
This product can not be used for any explosion-proof area.   
Do not use this product in a situation where human life may be affected.   
eYc-tech will not bear any responsibility for the results produced by the operators! 

Warning! 

 

Installation and wiring must be performed by qualified personnel in accordance with 
all applicable safety standards.   

 

This product must be operated under the operating conditions specified in manual to 
prevent equipment damages. 

 

Please using the product under the ordinary pressure, or it will influence safe problem. 

 

This product must be operated under the operating condition specified in this manual 
to prevent equipment damages.   

 

This product must be operated under the normally atmospheric condition to prevent 
equipment damages.   

 

To prevent products damage, always disconnect the power supply from the product 
before performing any wiring and installation. 

 

All wiring must comply with local codes of indoor wiring and electrical installation 
rules.   

 

Please use crimp type terminal.   

 

To prevent personal injury, do not touch the moving part of product in operation.   

 

It may cause high humidity atmosphere during the product was breakdown. Please 
take safety strategy. 

 

CE   
Emissions 
EN 61326-1:2006 EN 55011:2009/A1:2010 
Immunity 
EN 61326-1:2006 EN 61000-4-2:2009 EN61000-4-3:2006/A2:2010 EN61000-4-8:2010 
 
 
 
 
 

Summary of Contents for FTS34

Page 1: ...eYc FTS34 35 Operation Manual eYc FTS34 35 Thermo Air Velocity Transmitter...

Page 2: ...ent I Security considerations P 02 II Connection P 03 1 Analog diagram P 03 2 RS 485diagram P 03 3 Analog RS 485 diagram P 03 III DIP Switch P 04 1 Zero Button P 05 2 RS 485 Modbus P 05 IV Software an...

Page 3: ...s Please using the product under the ordinary pressure or it will influence safe problem This product must be operated under the operating condition specified in this manual to prevent equipment damag...

Page 4: ...www eyc tech com 3 Thermo Air Velocity Transmitter Air Velocity II Connection 1 Analog diagram 2 RS 485 diagram 3 Analog RS 485 diagram...

Page 5: ...order to read the DIP switch status again by software the user must to reboot again if re setting the DIP switch The function of DIP Switch_2 8 only be effective while setting the DIP switch_1 as On W...

Page 6: ...provide the device setting and data logging function it also can free download from website Technical data Max network size 32 transmitters Communication with COM Port Serial interface of PC Max netw...

Page 7: ...ick item Config and then setting COM port BAUD rate and data format pressed Scan bottom for scan devices and Apply for connection 4 Scan RS 485 connection Open the UI go to function Interface click it...

Page 8: ...second 80 filter 120 second etc Analog type 0 20 mA 4 20 mA 0 1 V 0 5 V 1 5 V 0 10 V 2 10 V Range for Upper and Lower 6 Setting on RS 485 and offset adjustment Station ID 1 247 Baud rate 9600 19200 38...

Page 9: ...www eyc tech com 8 Thermo Air Velocity Transmitter Air Velocity 7 Data display and logging Flow velocity unit m s ft s km h mph knot Temperature unit C F Export file CSV 8 Device information...

Page 10: ...oting Sensor maintenance Do not damage sensor surface during the maintenance process Troubleshooting If any problem occurs during operation refer to the table below for appropriate solutions Problem C...

Page 11: ...Thermo Air Velocity Transmitter Air Velocity Tel 886 2 8221 2958 Web www eyc tech com e mail info eyc tech com Sustainable Green Professional Temp Humid Dew Point Air Velocity Volume Flow Pressure Me...

Reviews: