![EXXOTEST DTM7000 User Manual Download Page 18](http://html1.mh-extra.com/html/exxotest/dtm7000/dtm7000_user-manual_2457458018.webp)
DTM7000
18
Doc.: 00293978-v1
Module DTM7008:
This module represents the flasher unit, which actuates the instrument panel repeaters, the internal
hazard warning button and the indicators themselves.
ID
Description
Functionalities
positive
Unit supply
Supply with APC at rest and positive from battery when
active
0v
System earth
Earth
C
Output to Terminal 7 on the
DTM7007
When à current is drawn through terminal C to the DTM7007
a square wave signal will be created.
R
Instrument panel repeater light
When the hazard warning switch is pressed the instrument
panel indicator is supplied.
Supply to flasher
unit from Terminal 1
on the DTM7007
Output to Terminal
7 on the DTM7007
Instrument
panel
repeater light
Instrument
panel
trailer repeater light