Operating Manual
15
3.1.9.2 iANTMB05
316L SS Antenna bracket 365mm length for 3 iANT100 / iANT200
antennas for mounting on an iWAP enclosure
Bespoke mounting brackets can also be designed for most applications. Please
contact Extronics for more information.
3.1.10 Setting to work
•
Once all cables are connected correctly, refit the enclosure lid using the four
screws previously removed. Use a torque screwdriver set to 2.5 Nm. Do not
over tighten screws.
•
Refer to the original manufacturers instructions for a detailed information on
setting the network to work correctly.
Important
Ensure the lid is secure, correct cable glands are fitted and the unit
device correctly wired and earthed for the particular application before
applying power.
Important
The iWAP200 is supplied fitted with anti-seize grease on the lid screws.
Ensure that this is not removed during installation. See section 4.3.1 for
maintenance details.
Important
Ensure that the lid gasket is clean and undamaged before fitting the lid.
Take care not to trap the lid earth cable in the gasket when closing the
lid.