Important 

Only  connectors  110/230VAC  Input,  Chassis  Earth  and  Ethernet  Input 
(Terminals  or  RJ45)  are  user  serviceable.  The  end  user  should  not 
connect, disconnect or alter the wiring on any other connector! 

 

Caution 

When  powering  the  iWAP200  via  POE  do  not  apply  an  external  power 
supply to the protection board. 

 

Caution 

Never power the iWAP200 via POE if fans and/ or heaters are installed.   

 

3.1.4 

Fibre Ethernet Input 

Important      When connecting the access point via a fibre connection do not use  
                       any of the two Ethernet inputs of connectors. 

 
To obtain greater wired link distances the iWAP200 can be shipped with an optional 
fibre module. The fibre module will be connected directly to the access point, the user 
should attach the fibre cable directly to the fibre module. The fibre cable should be 
fed through the Ethernet cable gland. 
 
If a multimode fibre option has been specified the connection is mage via a 

ST

 

connector.

  

 

If a single mode fibre option has bee

n specified, the connection is made via a “SC” 

connector. 

 

Important          The  fibre  cable  must  enter  the  iWAP200  enclosure  via  a  cable  gland,  it  

therefore may be necessary to terminate the Fibre cable, with the correct 
connector,  from  within  the  enclosure  after  the  cable  has  been  fed 
through the cable gland. 

 

3.1.5 

24VDC Variant Cable Installation 

Diagram 3.1.5.1 shows the connectors on the 24VDC variant of the iWAP200. Table 
3.1.5.2 describes the pin out connection required for operation. There are two blocks 
of screw terminals and one RJ45 connector. The Ethernet input screw terminals are 
wired in parallel with the RJ45 connector. Do not make an Ethernet connection to the 
RJ45 connector and the screw terminals at the same time, the installer should use 
only one of these connectors. 
 
Follow the instructions in section 3.1.2 to correctly prepare the cables and feed them 
through the correct cable gland. Follow table 3.1.5.2 to connect the correct cable to 
the correct screw terminal. If using the RJ45 connector instead of the screw terminals 
simply connect the Cat-5 cable to the connector and ensure the cable is securely in 
place. 

 

Caution 

Only  ever  connect  one  Ethernet  cable  to  either  the  RJ45  connector  or 
Ethernet screw terminals. 

 
 

Summary of Contents for iWAP200

Page 1: ...Installation Operating Manual iWAP200...

Page 2: ...is document is Copyright Extronics limited Extronics reserve the right to change this manual and its contents without notice the latest version applies Warranty For full details of the Extronics warra...

Page 3: ...Input 13 3 1 7 Thermostat Control 13 3 1 8 Fitting the antennas 13 3 1 9 Mounting The Antennas 14 3 1 10 Setting to work 15 4 Intended Purpose Usage 16 4 1 Transportation and Storage 16 4 2 Authorize...

Page 4: ...that Extronics can provide an OEM a solution to enable your WLAN network devices to be installed in hazardous areas The Extronics iWAP200 is designed for use with one to four standard antennas or Ext...

Page 5: ...ng the relevant standards and where applicable in accordance with IEC 79 17 on electrical apparatus for explosive atmospheres Warning For the installation maintenance and cleaning of the units it is a...

Page 6: ...re ensure the assembly is mounted using suitable fixtures Caution When powering the iWAP200 via POE do not apply an external power supply to the protection board Caution Never power the iWAP200 via PO...

Page 7: ...nformation Do not exceed the Effective Isotropic Radiated Power EIRP limit for the country region of operation Information For legacy reasons the RF outputs of the iWAP200 remain approved in accordanc...

Page 8: ...io 2 R2 on any manufacturers Wireless Access point A will be antenna port 1 B will be antenna port 2 and C will be antenna port 3 For example If you have ordered 1 N type connector for Radio 1 and 2 N...

Page 9: ...supplied by Extronics are used these must be M20 sized cable glands meeting the requirements of EN60079 0 2009 for ATEX Category III GD equipment and not compromise the IP66 rating of the iWAP200 encl...

Page 10: ...e to these screw terminals for the connection of the Ethernet input The pinouts on this terminal correspond with the standard cat 5 TIA EIA 568 B T568B wiring methods Only one Ethernet input should be...

Page 11: ...s made via a SC connector Important The fibre cable must enter the iWAP200 enclosure via a cable gland it therefore may be necessary to terminate the Fibre cable with the correct connector from within...

Page 12: ...inouts on this terminal correspond with the standard Cat 5 TIA EIA 568 B T568B wiring methods Only one Ethernet input should be made only use either the terminals or RJ45 connector NOT both Ethernet I...

Page 13: ...s are currently not user configurable The default configuration is for the heaters to be turned on when the internal ambient temperature is between 20oC and 30oC and for the fans wireless hardware to...

Page 14: ...ve been approved for use by Extronics for the area which they are to be installed may be used with iWAP200 Important Any plastic coated antenna shall have a warning label fitted to it stating WARNING...

Page 15: ...ighten screws Refer to the original manufacturers instructions for a detailed information on setting the network to work correctly Important Ensure the lid is secure correct cable glands are fitted an...

Page 16: ...red that they are not subjected to any excessive mechanical stresses 4 2 Authorized Persons Only persons trained for the purpose are authorized to handle the iWAP200 they must be familiar with the uni...

Page 17: ...bserve the applicable regulations and provisions concerned with explosion protection EN 60079 0 EN 60079 14 as well as the Accident Prevention Regulations 4 5 Cleaning and Maintenance Intervals The cl...

Page 18: ...e input option on ST connectors 100BaseLX 10 Single mode fibre on SC connectors Note that connectors may be specified as an option in the ordering data Output Connections Up to 6 energy limited extern...

Page 19: ...Operating Manual 19 6 Enclosure Dimensions...

Page 20: ...77 5000 Fax 44 0 845 277 4000 E mail Info extronics com W eb www extronics com xxxx Voltage EPSILON 08 ATEX 2394X II 3G Ex nAnL IIC T3 20 C Ta 70 C T4 20 C Ta 65 C T5 20 C Ta 30 C EPSILON 08 ATEX 2395...

Page 21: ...ire Extronics to supply the wireless network hardware Specify option 3 Power Supply Universal 90 264VAC If heater option 7 selected the unit cannot have a universal voltage it will be either 115VAC or...

Page 22: ...Operating Manual 22 9 EU Declaration of Conformity...

Page 23: ...Operating Manual 23...

Reviews: