Operating Manual
11
Important
Only connectors 110/230VAC Input, Chassis Earth and Ethernet Input
(Terminals or RJ45) are user serviceable. The end user should not
connect, disconnect or alter the wiring on any other connector!
Caution
When powering the iWAP200 via POE do not apply an external power
supply to the protection board.
Caution
Never power the iWAP200 via POE if fans and/ or heaters are installed.
3.1.4
Fibre Ethernet Input
Important When connecting the access point via a fibre connection do not use
any of the two Ethernet inputs of connectors.
To obtain greater wired link distances the iWAP200 can be shipped with an optional
fibre module. The fibre module will be connected directly to the access point, the user
should attach the fibre cable directly to the fibre module. The fibre cable should be
fed through the Ethernet cable gland.
If a multimode fibre option has been specified the connection is mage via a
“
ST
”
connector.
If a single mode fibre option has bee
n specified, the connection is made via a “SC”
connector.
Important The fibre cable must enter the iWAP200 enclosure via a cable gland, it
therefore may be necessary to terminate the Fibre cable, with the correct
connector, from within the enclosure after the cable has been fed
through the cable gland.
3.1.5
24VDC Variant Cable Installation
Diagram 3.1.5.1 shows the connectors on the 24VDC variant of the iWAP200. Table
3.1.5.2 describes the pin out connection required for operation. There are two blocks
of screw terminals and one RJ45 connector. The Ethernet input screw terminals are
wired in parallel with the RJ45 connector. Do not make an Ethernet connection to the
RJ45 connector and the screw terminals at the same time, the installer should use
only one of these connectors.
Follow the instructions in section 3.1.2 to correctly prepare the cables and feed them
through the correct cable gland. Follow table 3.1.5.2 to connect the correct cable to
the correct screw terminal. If using the RJ45 connector instead of the screw terminals
simply connect the Cat-5 cable to the connector and ensure the cable is securely in
place.
Caution
Only ever connect one Ethernet cable to either the RJ45 connector or
Ethernet screw terminals.