iCAM100 Installation and Operating Manual
5
2
Safety Information and Notes
2.1
Storage of this Manual
Keep this user manual safe and in the vicinity of the device. All persons required
to work on or with the device should be advised on where the manual is stored.
2.2
Special Conditions for Safe Use
2.2.1
ATEX
2.2.1.1
Camera Module (taken from Sira 01ATEX1366X)
The free end of the permanently connected cable shall be protected in
accordance with EN60079-0:2006 Clause 14.1.
In accordance with EN 60079-1:2007 Clause C.2.1.4, the rear end of
bushing shall be protected by fitting it into a suitably certified enclosure.
In addition, the bushing must not be subject to torque during installation.
The product shall not be connected to portable equipment.
The product that is fitted with a window has only been subjected to
reduced risk impact tests in accordance with EN 60079-0:2006 Clause
26.4.2; therefore it shall not be mounted in an area where there is a high
risk of impact.
The product shall be earthed in accordance with EN 60079-0:2006 Clause
15 when fitted to a suitably certified enclosure.
2.2.1.2
Cable Gland (taken from Sira 01ATEX1272X)
The Gland is only suitable in the temperature range of -60°C to +90°C
The Gland is only suitable for fixed installations. Cables must be effectively
clamped to prevent twisting or pulling.
The Gland is capable of providing ingress protection of IP66.
2.2.1.3
Ex e enclosure (taken from Sira 99ATEX3200X)
None