IR Remote Control

The IR 601 infrared remote control can perform all the
functions that are available via the front panel controls
except the genlock adjustments.

The IR 601 remote control can freeze
the image, set filtering adjustments,
zoom in and out, resize and shift the
image.  The push-buttons for these
functions on the IR 601 work exactly
like those on the VSC 150’s front
panel.  To function properly, the line
of sight between the IR controller and
the VSC 150 must be unobstructed.

The Power/signal lock LED
blinks while the VSC 150
receives commands from the
IR 601.

If the VSC 150 is set for
Executive mode,
adjustments can be made
via the IR remote control.

All controls except Freeze
will be locked on the IR 601
while Freeze mode is active.
Press the Freeze button
again to turn off Freeze
mode and unlock the other
controls.

3-7 

VSC and DDS Control Program window

Control software for Windows

The included graphical control software for Windows offers
another way to control the VSC 150 via RS-232 connection
in addition to the Simple Instruction Set commands listed
on pages 3-4 to 3-5.  The control software is compatible with
Windows 3.1/3.11, Windows 95/98 and Windows NT.  The
VSC 150 uses version 3.1 or higher of Extron’s VSC and
DDS Control Program, which is included with the VSC 150.

Installing the software

The control program is contained on a single 3.5-inch
diskette, and it can run from the floppy drive.  However, it
is more convenient to run the program from the hard drive.

To install the software on the hard drive, run SETUP.EXE
from the floppy disk, and follow the instructions that
appear on the screen.  The program requires approximately
1 MB (megabyte) of hard disk space.

By default the installation creates a C:\VSC200 directory,
and it places two icons (VSC + DDS Control Pgm and
VSC + DDS Help) into a group or folder named “Extron
Electronics”.

Using the software

1.

To run the VSC and DDS Control Program, double-

click on the VSC + DDS Control Pgm
icon in the Extron Electronics group or
folder.  The Comm menu appears on the
screen.

2.

Click on the comm port that is connected to the
VSC 150’s RS-232 port.  The Extron VSC and DDS
Control Program window appears.  It displays the
current settings.  See the illustration on the next page.

For information on program features, press the F1

computer key or click on the Help menu from
within the control program, or double-click
on the VSC + DDS Help icon in the Extron
Electronics group or folder.

3-6

The IR 601 remote

Summary of Contents for VSC 150

Page 1: ...AH Amersfoort 31 33 453 4040 FAX 31 33 453 4050 The Netherlands Extron Electronics Asia 135 Joo Seng Rd 04 01 PM Industrial Bldg 65 383 4400 FAX 65 383 4664 Singapore 368363 Extron Electronics Informa...

Page 2: ...bjekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung Alle Wartungsma nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind...

Page 3: ...witching 2 13 Vertical interval switching setup 2 13 Genlock setup 2 14 Oscilloscope displays 2 16 Troubleshooting 2 17 If the image does not appear 2 17 If the image does not display correctly 2 18 I...

Page 4: ...tents cont d VSC 150 1 Chapter One Introduction About this Manual About the VSC 150 Features 68 469 01 D Printed in the USA 01 01 Appendix Specifications Accessories and Part Numbers A 1 Specification...

Page 5: ...omposite sync Y R Y B Y component video or S video output Genlock burst lock synchronization The VSC 150 can be connected to a genlock burst lock black burst sync signal generator via rear panel conne...

Page 6: ...signals Genlocking provides for seamless vertical interval switching between the scan converted signal and signals from other video sources VGA or Macintosh input and local monitor output The 15 pin...

Page 7: ...rack as shown above Installation and Operation Installation Overview To install and set up the VSC 150 follow these basic steps 1 Turn all of the equipment off Make sure that the source computer the V...

Page 8: ...th display outputs simultaneously The image is resized no matter what format is selected RGB component S video or composite video The local monitor loop out is not affected The size function remains a...

Page 9: ...DEO PAL OUT 75 OHM VIDEO MAC VGA I N P U T S O U T P U T S 5 3 6 2 8 9 10 4 7 1 Continued 2 7 default to the standard centering and pan functions To turn the size feature off press the Size button aga...

Page 10: ...s setting when the system includes a local monitor 5 Composite video Video output connector Composite video output is continuously available on this BNC connector 6 S video output connector This 4 pin...

Page 11: ...rding device to the composite video output BNC connector 5 Select the format of the second output by setting the output selection toggle switch 6 Connect a cable from the input of the second video dis...

Page 12: ...ter the picture by rotating the vertical and horizontal Centering Pan Size rotary controls 5 Repeat steps 1 through 4 as needed Select the filtering levels 1 Press the horizontal vertical and encoder...

Page 13: ...ted sync signal must be used for the genlock timing source 9 Once the settings are stable and the Burst Lock LED lights disconnect the oscilloscope and reconnect the genlock cables and terminator to t...

Page 14: ...sirable artifacts in the image s Make adjustments as necessary Once the genlock timing has been adjusted it should not require readjustment when changing to a new computer video signal input 11 If oth...

Page 15: ...s l o r t n o c r o l o c d n a t n i t e u h e h t t s u j d A e c i v e d y a l p s i d e h t y a l p s i d o e d i v e h t t a h t e r u s e k a M e m a s e h t g n i s u s i t n e m p i u q e g n...

Page 16: ...VSC 150 Installation and Operation Installation and Operation cont d VSC 150 3 Chapter Three Remote Control RS 232 Remote Control IR Remote Control 2 20...

Page 17: ...n Locations Female 5 1 9 6 The VSC 150 can be remotely controlled via a computer or a control panel attached to the rear panel RS 232 connector Alternatively the VSC 150 can be controlled using the IR...

Page 18: ...312 01 Display VSC 150 s part Request information Command I i 49 69 see below Display status Response Dhz X1 Dvt X2 Enc X3 Frz X5 Exe X5 X2 Vertical filtering level 1 through 3 X3 Encoder filtering l...

Page 19: ...e control software is compatible with Windows 3 1 3 11 Windows 95 98 and Windows NT The VSC 150 uses version 3 1 or higher of Extron s VSC and DDS Control Program which is included with the VSC 150 In...

Page 20: ...the desired computer video source by using the front panel controls RS 232 commands or the IR 601 controls 2 Press the Store button in the Memory area of the IR 601 control The Power signal lock LED f...

Page 21: ...female uses the R G and B BNCs Composite video 1 BNC female Nominal level RGBHV RGBS component 0 7V p p S video composite video 1 0V p p Impedance 75 ohms Sync Input type Autodetect RGBHV RGBS RGsB Ou...

Page 22: ...0 Included parts Part number VSC 150 60 312 01 Mac HV VGA cable 6 feet 26 462 01 S video cable 6 feet 26 316 02 75 ohm BNC termination adapter 26 300 01 IR 601 remote controller VSC 150 User s Manual...

Page 23: ...VSC 150 Accessories and Part Numbers Accessories and Part Numbers cont d A 6...