Extron electronics VSC 150 User Manual Download Page 10

VSC 150 • Installation and Operation

VSC 150 • Installation and Operation

Installation and Operation, cont’d

Cabling

Attach cables to the scan converter as detailed in the steps
below.  A diagram on page 2-11 shows how the system
looks when cabling is finished.

1

.

Connect the local monitor via its video input cable to
the corresponding (Mac or VGA) “input” connector
on the VSC 150’s rear panel.

2

.

Using the included Mac-VGA cable, connect the
computer’s video output to the other input connector.
See the diagram below and the pin assignment
information on page 2-12.

If the source computer is a Macintosh, plug the
VGA (15-pin HD) end into the VSC 150, and plug
the other (15-pin D) end into the computer’s
output connector.

If the source computer is a VGA-type PC, plug
the Mac (15-pin D) end into the VSC 150, and
plug the other (15-pin HD) end into the
computer’s output connector.

50/60 Hz

100-240 V      0.3A

P

AL OUT

75 OHM

MAC

VGA

I

N
P
U
T
S

50/60 Hz

100-240 V      0.3A

P

AL OUT

75 OHM

MAC

VGA

I

N
P
U
T
S

PC Computer

Mac Computer

Mac-VGA
cable

Mac-VGA
cable

Mac-VGA cable local monitor connections

If a local monitor will not be used, set the 75 Ohm DIP
switch to On (75 ohms), or install a termination
adapter on the unused local monitor connector.

2-9

2 — 75 Ohm (video input termination)

 —  This switch

provides a way to prevent blooming when no local
monitor or termination adapter is connected.

ON — The VSC 150 provides 75 ohm video input

termination.  Select this setting when a
local monitor is not used.

OFF — The VSC 150 provides high Z (high

impedance) video input termination.  Use
this setting when the system includes a
local monitor.

5

Composite video (Video) output connector

 —

Composite video output is continuously available on
this BNC connector.

6

S-video output connector

 —  This 4-pin mini-DIN

connector is for S-video output.

7

Output selection switch

 —  In addition to the

composite video output, one other output can
also be active.  Choose from the following
formats via the output selection switch:

• S-video output (select S-video),
• RGBS (composite sync) output (select RGB),
• RGBHV (separate horizontal and vertical sync)

(select RGB), or

• Y, R-Y, B-Y (component video) output

(select R-Y/B-Y/Y).

The output cables must also be connected to the
appropriate connector(s) for the second output.

Connect cables for only one output in addition to
the composite video output.  Do not connect
cables to outputs that will not be used for your
application.  Connecting cables to more outputs
will overload the circuits and yield weak signals.

8

RGB/component video output connectors

 —  These

BNC female connectors are for RGB output (red, green,
and blue video output; and horizontal, vertical, and
composite sync output), or for component video output
(R-Y, Y, B-Y).  See “Cabling” in this chapter for details.

9

Genlock connectors

 —  A genlock (black burst

generator) device can be connected to the VSC 150 via
these female BNC connectors to synchronize it with
other system components for seamless vertical interval

R-Y/B-Y/Y

RGB

S-VIDEO

2-8

switching between sources.  See “Cabling” and
“Setting Up Genlock and Vertical Interval Switching”
in this chapter.

10

RS-232 connector

 —  Connect a computer or RS-232

control module to this 9-pin D connector to allow
remote control using the Simple Instruction Set or the
Extron graphical control program for Windows.  See
chapter 3, “Remote Control” for details.

Summary of Contents for VSC 150

Page 1: ...AH Amersfoort 31 33 453 4040 FAX 31 33 453 4050 The Netherlands Extron Electronics Asia 135 Joo Seng Rd 04 01 PM Industrial Bldg 65 383 4400 FAX 65 383 4664 Singapore 368363 Extron Electronics Informa...

Page 2: ...bjekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung Alle Wartungsma nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind...

Page 3: ...witching 2 13 Vertical interval switching setup 2 13 Genlock setup 2 14 Oscilloscope displays 2 16 Troubleshooting 2 17 If the image does not appear 2 17 If the image does not display correctly 2 18 I...

Page 4: ...tents cont d VSC 150 1 Chapter One Introduction About this Manual About the VSC 150 Features 68 469 01 D Printed in the USA 01 01 Appendix Specifications Accessories and Part Numbers A 1 Specification...

Page 5: ...omposite sync Y R Y B Y component video or S video output Genlock burst lock synchronization The VSC 150 can be connected to a genlock burst lock black burst sync signal generator via rear panel conne...

Page 6: ...signals Genlocking provides for seamless vertical interval switching between the scan converted signal and signals from other video sources VGA or Macintosh input and local monitor output The 15 pin...

Page 7: ...rack as shown above Installation and Operation Installation Overview To install and set up the VSC 150 follow these basic steps 1 Turn all of the equipment off Make sure that the source computer the V...

Page 8: ...th display outputs simultaneously The image is resized no matter what format is selected RGB component S video or composite video The local monitor loop out is not affected The size function remains a...

Page 9: ...DEO PAL OUT 75 OHM VIDEO MAC VGA I N P U T S O U T P U T S 5 3 6 2 8 9 10 4 7 1 Continued 2 7 default to the standard centering and pan functions To turn the size feature off press the Size button aga...

Page 10: ...s setting when the system includes a local monitor 5 Composite video Video output connector Composite video output is continuously available on this BNC connector 6 S video output connector This 4 pin...

Page 11: ...rding device to the composite video output BNC connector 5 Select the format of the second output by setting the output selection toggle switch 6 Connect a cable from the input of the second video dis...

Page 12: ...ter the picture by rotating the vertical and horizontal Centering Pan Size rotary controls 5 Repeat steps 1 through 4 as needed Select the filtering levels 1 Press the horizontal vertical and encoder...

Page 13: ...ted sync signal must be used for the genlock timing source 9 Once the settings are stable and the Burst Lock LED lights disconnect the oscilloscope and reconnect the genlock cables and terminator to t...

Page 14: ...sirable artifacts in the image s Make adjustments as necessary Once the genlock timing has been adjusted it should not require readjustment when changing to a new computer video signal input 11 If oth...

Page 15: ...s l o r t n o c r o l o c d n a t n i t e u h e h t t s u j d A e c i v e d y a l p s i d e h t y a l p s i d o e d i v e h t t a h t e r u s e k a M e m a s e h t g n i s u s i t n e m p i u q e g n...

Page 16: ...VSC 150 Installation and Operation Installation and Operation cont d VSC 150 3 Chapter Three Remote Control RS 232 Remote Control IR Remote Control 2 20...

Page 17: ...n Locations Female 5 1 9 6 The VSC 150 can be remotely controlled via a computer or a control panel attached to the rear panel RS 232 connector Alternatively the VSC 150 can be controlled using the IR...

Page 18: ...312 01 Display VSC 150 s part Request information Command I i 49 69 see below Display status Response Dhz X1 Dvt X2 Enc X3 Frz X5 Exe X5 X2 Vertical filtering level 1 through 3 X3 Encoder filtering l...

Page 19: ...e control software is compatible with Windows 3 1 3 11 Windows 95 98 and Windows NT The VSC 150 uses version 3 1 or higher of Extron s VSC and DDS Control Program which is included with the VSC 150 In...

Page 20: ...the desired computer video source by using the front panel controls RS 232 commands or the IR 601 controls 2 Press the Store button in the Memory area of the IR 601 control The Power signal lock LED f...

Page 21: ...female uses the R G and B BNCs Composite video 1 BNC female Nominal level RGBHV RGBS component 0 7V p p S video composite video 1 0V p p Impedance 75 ohms Sync Input type Autodetect RGBHV RGBS RGsB Ou...

Page 22: ...0 Included parts Part number VSC 150 60 312 01 Mac HV VGA cable 6 feet 26 462 01 S video cable 6 feet 26 316 02 75 ohm BNC termination adapter 26 300 01 IR 601 remote controller VSC 150 User s Manual...

Page 23: ...VSC 150 Accessories and Part Numbers Accessories and Part Numbers cont d A 6...