TLP Pro 525T, 725T, and 1025T Series • Setup Guide
Overview
The TLP Pro 525 Series are 5-inch tabletop capacitive touchscreens with a resolution of 800x480 and 24-bit color depth.
The TLP Pro 725T Series are 7-inch tabletop capacitive touchscreens with a resolution of 1024x600 and 24-bit color depth.
The TLP Pro 1025T Series are 10-inch tabletop capacitive touchscreens with a resolution of 1280x800 and 24-bit color depth.
All these models can be placed on any convenient flat surface.
This guide provides instructions for experienced installers to install these touchpanels. For complete instructions, see the
TLP Pro 525, 725, and 1025 Series User Guide
, at
www.extron.com
.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
GUI Designer
— for designing layouts for Extron TouchLink
®
Pro touchpanels and third party touch interfaces
Global Configurator
®
Professional
or
Global Configurator Plus
— for setting up and configuring the control processor
and touchpanel
Toolbelt
— provides device discovery, device information, firmware updates, and configuration of network settings,
system utilities, and user management for TouchLink Pro devices
Global Scripter
®
— provides an integrated development environment for Extron control systems programming
NOTE:
All four software programs are available from
www.extron.com
.
Obtain the following network information from your network administrator:
DHCP status (on or off). If DHCP is off, you must also obtain:
IP address
Subnet mask
Gateway
Username — This can be either
admin
or
user
.
Password — By default this is
extron
(for either admin or user).
Make a note of the touchpanel MAC address.
Mount and Cable All Devices
ATTENTION:
•
Do not power on the touchpanels until you have read the
ATTENTION
in the “Base” section of the
TLP Pro 525, 725,
and 1025 Series User Guide
.
•
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde dans la section « Base » du
TLP Pro 525, 725,
and 1025 Series User Guide
.
Mount the units. There are several mounting options for TouchLink Pro touchpanels (see
Mounting
on the next page).
Connect the touchpanel to a Power over Ethernet injector (not provided). Extron recommends the XTP PI 100 power injector,
which must be purchased separately.
Connect the power injector to the LAN and power it on.
Set up the Touchpanels for Network Communication
Connect the PC that you are using for setup, the control processor, and touchpanel to the same Ethernet subnetwork.
Use the
Setup Menu
(see page 4) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask,
gateway, and related settings for the touchpanel.
Configure the Touchpanels
Create a graphical user interface with GUI Designer (see
GUI Designer Help File
for step-by-step instructions).
Associate functions with the graphical user interface features by configuring (see the
Global Configurator Help File
) or
programming (see the
Global Scripter Help File
) the system. Global Scripter provides an Extron-exclusive Python library
(ControlScript
®
) and Global Scripter modules to get you started.
1
Product Category
IMPOR
TANT
:
Go to
for th
e
complete user guide and installation
instructions befor
e connecting the
product to the power sou
rce.