background image

Configuring the TLP 700MV (Initial Setup)

Before using the TLP 700MV, it is essential to configure it using the on-screen menus. There are five different screens (Main, Volume, 
Time, Network, and Video) that can be selected by pressing the appropriate button at the left side of the screen. There is also an Exit 
button at the bottom left corner of the screen for leaving the menus.

Setup Menu

Press the recessed 

Menu

 button to activate the top-level menu screen. The 

menu opens at the 

Main

 Setup Page.

Touch an area of the screen to bring it into focus and use the 

Up

 and 

Down

 

buttons or the volume control knob to adjust the value. Some options 
have a single button and toggle between 

Off

 and 

On

 when the button is 

pressed.
Use the different menu pages to adjust the following options. For 
more details, see the 

TLP 700MV and TLP 700TV User Guide

 at 

www.extron.com

.

Main

  (see figure 3) — Adjusts the 

Sleep

 

timer

Backlight

Auto

 

Backlight

LED

 

Backlight

, and 

Wake

 

on

 

Motion

 functions.

Volume

 — Adjusts the 

Master

Click

Sounds

, and 

Line

 

In

 volume 

settings.

Time

 — Sets the correct time and date.

Network

 — Sets the IP address and the subnet mask, and enables or 

disables Dynamic Host Configuration Protocol.

Video

 — Provides a small video preview window and the controls to set up 

the video contrast, color, brightness, and tint.

Figure 3. 

Setup Menu

Calibration Menu

While in the 

Setup

 menu, press the 

Menu

 button a second time to open 

the calibration-screen. When all four points have been calibrated, the 
screen reopens to the 

Setup

 screen.

Press 

Exit

 to close the on-screen menus.

Reattach the faceplate (see 

Figure 2

 on page 2).

Figure 4. 

Calibration Screen

Reset Modes

The TLP 700 MV has four reset modes that can be initiated by pressing the 

Reset

 button.

NOTE: 

See the 

TLP 700MV and TLP 700TV User Guide

 at 

www.extron.com

 for additional details.

• 

Factory Firmware Mode

 — Hold the 

Reset

 button while applying power to reset the unit back to the base firmware shipped 

with the unit.

• 

Run/Stop Events Mode

 — Hold the 

Reset

 button until the reset LED blinks once (3 seconds), then release and press 

Reset

 

momentarily (less than 1 second) within 1 second.
This mode turns events on or off.

• 

Reset All IP Settings Mode

 — Hold the 

Reset

 button until the reset LED blinks twice (6 seconds), then release and press 

Reset

 momentarily (less than 1 second) within 1 second.

This mode resets the IP address, subnet, gateway, port mapping, and DHCP settings back to factory defaults. The reset LED 
blinks 4 times in quick succession, confirming the reset and turning events off. If necessary, reset the IP address, using ARP and 
the MAC address.

• 

Reset Factory Defaults Mode

 — Hold the 

Reset

 button until the reset LED blinks 3 times (9 seconds), then release and press 

Reset momentarily (less than 1 second) within 1 second.
This mode causes a reset to factory defaults for everything except firmware.

NOTES:

• 

The factory configured passwords for all accounts on this device have been set to the device serial number. Passwords 
are case sensitive.

• 

If the device is reset to default settings, the password will be the default password configuration. The default password 
is extron.

 

3

Product Category

Summary of Contents for TLP 700MV

Page 1: ...ten backlit push buttons five on either side of the screen can be configured using the Extron Global Configurator software to control commonly used functions 2 Motion detector This detector is capped with a small Fresnel lens that focuses light onto the sensor When no motion has been detected for a user defined period of time the unit goes into sleep mode When motion is detected in the vicinity of...

Page 2: ...back of the TLP 700MV Use the provided power supply for correct operation ATTENTION Do not connect any external power supplies until you have read the Attention notifications in the Power Supply section of the TLP 700MV and TLP 700TV User Guide Ne branchez pas de sources d alimentation externes avant d avoir lu les mises en garde dans la section Power Supply du TLP 700MV and TLP 700TV User Guide 8...

Page 3: ...n calibrated the screen reopens to the Setup screen Press Exit to close the on screen menus Reattach the faceplate see Figure 2 on page 2 Figure 4 Calibration Screen Reset Modes The TLP 700 MV has four reset modes that can be initiated by pressing the Reset button NOTE See the TLP 700MV and TLP 700TV User Guide at www extron com for additional details Factory Firmware Mode Hold the Reset button wh...

Page 4: ...ions to the buttons and screen graphics and text When the functions have been assigned to all screen objects build the project and upload it to the IP Link controller For complete information consult the user guide for the controller Designing the TLP 700MV Interface with GUI Configurator Install the GUI Configurator software on a PC and use it to design the interface that will appear on the TLP 7...

Reviews: