Mounting
This section outlines the various options for mounting the TLI Pro 201.
•
•
•
Wall Mounting
The compact design of the TLI Pro 201 allows discreet installation within a lectern or to
the wall behind a flat panel display. See
www.extron.com
for a list of appropriate kits
and follow the instructions included with the kit.
Rack Mounting
The TLI Pro 201 can be mounted on any Extron standard rack system (not provided). See
www.extron.com
for a list of appropriate kits and follow the instructions included with
the kit and the guidelines listed below.
The UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines pertain to the installation of the TLI
Pro 201 enclosure into a rack:
CAUTION:
•
Elevated operating ambient temperature
— If the equipment is installed
in a closed or multi-unit rack assembly, the operating ambient temperature of
the rack environment may be greater than room ambient. Therefore, consider
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by Extron.
•
Reduced air flow
— Install the equipment in the rack so that the amount of air
flow required for safe operation of the equipment is not compromised.
•
Mechanical loading
— Mount the equipment in the rack so that uneven
mechanical loading does not create a hazardous condition.
•
Circuit overloading
— When connecting the equipment to the supply circuit,
consider the connection of the equipment to the supply circuit and the effect
that circuit overloading might have on overcurrent protection and supply wiring.
Consider equipment nameplate ratings when addressing this concern.
•
Reliable earthing (grounding)
— Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct
connections to the branch circuit (such as the use of power strips).
TLI Pro 201 • Mounting
30