z

Connect a high resolution digital input device to the DVI connector (input 3; 

f

).

 

z

Connect audio input devices to the audio captive screw connectors (inputs 1 through 3; 

h

) using cables with balanced 

or unbalanced 3.5 mm, 5-pole captive screw connectors. Audio 

cannot

 be streamed without a connected video input 

device. See the image below to wire the connectors.

Unbalanced Stereo Input

Balanced Stereo Input

Tip

Ring

Tip

Ring

LR

Sleeves

Tip

Sleeve

Sleeve

Tip

LR

Unbalanced Mono Input

Balanced Mono Input

(high impedance)

Tip

Ring

LR

Sleeve

Tip

Sleeve

LR

Do not tin the wires!

Step 3 — Connect Buffered Loop Output Devices (Optional)

If necessary, connect output devices to the following buffered loop connectors. Buffered loop connectors output the input 
device that is connected to a similar input connector (for example, BNC buffered loop connectors output BNC video). 

 

z

Connect a video output device to the component, S-video, composite BNC buffered loop connectors (

c

).

 

z

Connect a video output device to the 15-pin HD buffered loop connector (

e

).

 

z

Connect a high resolution digital output device to the DVI buffered loop connector (

g

).

 

z

Connect audio output devices to the buffered loop audio captive screw connectors (

i

) using cables with balanced or 

unbalanced 3.5 mm, 5-pole captive screw connectors. See the image below to wire the connectors.

CAUTION:

  For unbalanced audio, connect the sleeves to the ground contact. 

DO NOT

 connect the sleeves to the 

negative (–) contacts.

Balanced Audio Output

Tip

Ring

Tip

Ring

LR

Sleeves

Unbalanced Audio Output

Tip

Tip

LR

Sleeves

Do not tin the wires!

Step 4 — Connect RS-232 Control Device (Optional)

If necessary, connect a host computer or control system to the RS-232 connector (

j

). Use this port to send Simple 

Instruction Set (SIS™) commands to the SME 100 for device configuration and control. The default protocol for this port is 

9600 baud rate

no parity bit

8 data bits

1 stop bit

, and 

no flow control (handshaking)

.

Step 5 — Connect the SME 100 to the Network

Connect one end of an RJ-45 cable to the Ethernet connector (

l

) on the SME 100. Connect the other end of the RJ-45 cable 

to a router or switch to connect the SME 100 to a network.
The LEDs on the Ethernet connector indicate the status of the network connection. The green LED lights when connected to 
a network. The amber LED flickers as the SME 100 actively communicates with a network.

Step 6 — Connect Control PC and Viewing Devices to the SME 100 Network

Connect one end of an RJ-45 cable to a control PC or viewing device. Connect the other end of the RJ-45 cable to a router or 
switch to connect the control PC or viewing device to the network.

Step 7 — Power On the SME 100 and All Devices

Connect a standard IEC power cord into the AC power connector (

a

) of the SME 100 and plug it to a 100 to 240 VAC,  

50 Hz or 60 Hz power source. Connect the power cords of the input and output devices and turn them on.

Powering Up

When applying power to the SME 100, the unit undergoes a self testing sequence (see the image below). After the testing  
sequence is complete (and when the device is not being configured), the default display cycle is shown on the LCD display.  
The default display cycle shows the model name, firmware version, active input, input signal type, horizontal scan rate,  
vertical refresh rate, stream mode, output resolution, streaming method, and video bit rate in kilobits per second (Kbps).

Power

On

EXTRON 

ELECTRONICS

1

sec.

All input LEDs flash

once in sequence.

1

sec.

2

sec.

Last active input

LED remains lit

(here input 3).

= flashing

Key

1

3

= lit

SME 100 HD/SD

FW   V1.00

45

sec.

Default Display Cycle

2 sec.

2

sec.

In1   YUVp/HD

31kHz   60Hz

 640 x 480

OUTPUT   A/V

 BR     521 Kbps

UNICAST   RTP

2

sec.

NOTE: 

The information shown in the default display cycle may differ, 

  depending on the active input and type of video signal.

SME 100 HD/SD

FW   V1.00

2 sec.

SME 100 HD/SD

INITIALIZING

LOADING

FIRMWARE

30

sec.

~4

  sec.

Reviews: