![Extron electronics SME 100 Setup Manual Download Page 2](http://html1.mh-extra.com/html/extron-electronics/sme-100/sme-100_setup-manual_2456439002.webp)
2
SME 100 • Setup Guide (Continued)
z
Connect a high resolution digital input device to the DVI connector (input 3;
f
).
z
Connect audio input devices to the audio captive screw connectors (inputs 1 through 3;
h
) using cables with balanced
or unbalanced 3.5 mm, 5-pole captive screw connectors. Audio
cannot
be streamed without a connected video input
device. See the image below to wire the connectors.
Unbalanced Stereo Input
Balanced Stereo Input
Tip
Ring
Tip
Ring
LR
Sleeves
Tip
Sleeve
Sleeve
Tip
LR
Unbalanced Mono Input
Balanced Mono Input
(high impedance)
Tip
Ring
LR
Sleeve
Tip
Sleeve
LR
Do not tin the wires!
Step 3 — Connect Buffered Loop Output Devices (Optional)
If necessary, connect output devices to the following buffered loop connectors. Buffered loop connectors output the input
device that is connected to a similar input connector (for example, BNC buffered loop connectors output BNC video).
z
Connect a video output device to the component, S-video, composite BNC buffered loop connectors (
c
).
z
Connect a video output device to the 15-pin HD buffered loop connector (
e
).
z
Connect a high resolution digital output device to the DVI buffered loop connector (
g
).
z
Connect audio output devices to the buffered loop audio captive screw connectors (
i
) using cables with balanced or
unbalanced 3.5 mm, 5-pole captive screw connectors. See the image below to wire the connectors.
CAUTION:
For unbalanced audio, connect the sleeves to the ground contact.
DO NOT
connect the sleeves to the
negative (–) contacts.
Balanced Audio Output
Tip
Ring
Tip
Ring
LR
Sleeves
Unbalanced Audio Output
Tip
Tip
LR
Sleeves
Do not tin the wires!
Step 4 — Connect RS-232 Control Device (Optional)
If necessary, connect a host computer or control system to the RS-232 connector (
j
). Use this port to send Simple
Instruction Set (SIS™) commands to the SME 100 for device configuration and control. The default protocol for this port is
9600 baud rate
,
no parity bit
,
8 data bits
,
1 stop bit
, and
no flow control (handshaking)
.
Step 5 — Connect the SME 100 to the Network
Connect one end of an RJ-45 cable to the Ethernet connector (
l
) on the SME 100. Connect the other end of the RJ-45 cable
to a router or switch to connect the SME 100 to a network.
The LEDs on the Ethernet connector indicate the status of the network connection. The green LED lights when connected to
a network. The amber LED flickers as the SME 100 actively communicates with a network.
Step 6 — Connect Control PC and Viewing Devices to the SME 100 Network
Connect one end of an RJ-45 cable to a control PC or viewing device. Connect the other end of the RJ-45 cable to a router or
switch to connect the control PC or viewing device to the network.
Step 7 — Power On the SME 100 and All Devices
Connect a standard IEC power cord into the AC power connector (
a
) of the SME 100 and plug it to a 100 to 240 VAC,
50 Hz or 60 Hz power source. Connect the power cords of the input and output devices and turn them on.
Powering Up
When applying power to the SME 100, the unit undergoes a self testing sequence (see the image below). After the testing
sequence is complete (and when the device is not being configured), the default display cycle is shown on the LCD display.
The default display cycle shows the model name, firmware version, active input, input signal type, horizontal scan rate,
vertical refresh rate, stream mode, output resolution, streaming method, and video bit rate in kilobits per second (Kbps).
Power
On
EXTRON
ELECTRONICS
1
sec.
All input LEDs flash
once in sequence.
1
sec.
2
sec.
Last active input
LED remains lit
(here input 3).
= flashing
Key
1
3
= lit
SME 100 HD/SD
FW V1.00
45
sec.
Default Display Cycle
2 sec.
2
sec.
In1 YUVp/HD
31kHz 60Hz
640 x 480
OUTPUT A/V
BR 521 Kbps
UNICAST RTP
2
sec.
NOTE:
The information shown in the default display cycle may differ,
depending on the active input and type of video signal.
SME 100 HD/SD
FW V1.00
2 sec.
SME 100 HD/SD
INITIALIZING
LOADING
FIRMWARE
30
sec.
~4
sec.