Figure 3-1 — RCP 1000 top panel

1

Picture control button —

 Allows you to toggle through the

center, size, filter, and contrast/brightness picture controls,
which are used to adjust the preview image.  The program
image is not affected by these controls (unless the current
preview input is the same as the current program input).

2

Picture control LEDs —

 Indicate the active picture control.

3

Program input selection buttons —

 Allow the system operator

to view the image switch as it happens.  The button for the
currently selected program input is lit.

Freeze —

 Locks the output display to the image that is currently

displayed on the program output.

When an image is frozen, a switch can still occur.  When
the output is switched, the freeze command stays in effect.

To unfreeze the image, press the Freeze button.

If an image is frozen when a different input is selected or if
the unit loses power, the image unfreezes.

Black —

 Causes a black screen to be displayed.  The black

screen can be switched by applying a cut or another effect.
A black input cannot be frozen.

RCP 1000

REMOTE CONTROL PANEL

PROGRAM

FREEZE

BLACK

1

2

3

4

5

6

7

8

1

2

3

4

CUT

TAKE

PPREVIEW

FREEZE

BLACK

1

2

3

4

5

6

7

8

VERT

HORZ

CONT

BRIGHT

CENTER

SIZE

FILTER

COND/BRIGHT

TRANSITIONS

EFFECTS

COMMUNICATION

Tx
Rx

1

2

3

4

5

6

7

8

TAKE

FREEZE

BLACK

1

2

3

4

5

6

7

8

FREEZE

BLACK

CUT

1

2

3

4

5

6

7

1 – 8 —

 Selects the corresponding input to be displayed.

Normally, you will not use these buttons during a show.  If
a program input selection button is pressed, the resulting
switch is not seamless.

4

Transition buttons —

 Control the type of switch that will occur

between program and preview outputs.

Cut button —

 Initiates an immediate seamless switch between

the program and preview images.

Take button —

 Initiates the switch selected by the effects

buttons.

Effects buttons —

 Control the effect, transition, and duration of

transition effects.  The effects can have a transition time of
0.2 to 5 seconds.

5

SGS 408 Communication LEDs —

 Light to indicate that the

RCP 1000 is communicating with the SGS 408 unit.  When the
RCP 1000 is transmitting data to the SGS 408, the Tx LED is lit.
When the RCP 1000 is receiving  data from the SGS 408, the Rx
LED is lit.

6

Preview input selection buttons —

 Allow the system operator

to view the image before switching it to the program output.
The button for the currently selected preview input is lit.

Freeze —

 Locks the output display to the image that is currently

displayed on the preview output.

When an image is frozen, a switch can still occur.  When
the output is switched, the freeze command stays in effect.

To unfreeze the image, press the Freeze button.

If an image is frozen when a different input is selected or if
the unit loses power, the image unfreezes.

Black —

 Causes a black screen to be displayed.  The black

screen can be switched by applying a cut or another effect.
The black input cannot be frozen.

1 – 8 —

 Allow you to select the preview input device.  The

button is lit while the input is active.

7

Adjustment knobs —

 Allow you to make adjustments to the

picture controls for the preview output.  For example, if the
contrast/brightness picture control is active, turning the left
adjustment knob changes the contrast level, and turning the
right adjustment knob adjusts the brightness level.

3-3

Summary of Contents for RCP 1000

Page 1: ... Amersfoort 31 33 453 4040 FAX 31 33 453 4050 The Netherlands Extron Electronics Asia 135 Joo Seng Rd 04 01 PM Industrial Bldg 65 383 4400 FAX 65 383 4664 Singapore 368363 Extron Electronics Information ExtronWEB www extron com ExtronFAX 714 491 0192 24 hour access worldwide 2001 Extron Electronics All rights reserved Remote Control Panel 68 519 01 Printed in the USA RCP 1000 ...

Page 2: ...itsfunktion dar Diese sollte nicht umgangen oder außer Betrieb gesetzt werden Stromunterbrechung Um das Gerät auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der Rückseite des Gerätes aus der externen Stomversorgung falls dies möglich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels Netzkabel sollten stets so verlegt werden daß sie nicht im Weg liegen und niemand da...

Page 3: ...Picture Controls 3 4 Centering an image 3 4 Sizing an image 3 4 Filtering an image 3 4 Adjusting contrast and brightness 3 4 Applying a Switch 3 5 Applying a cut 3 5 Applying other effects 3 5 Available effects 3 5 Implementing an effect 3 7 Implementing a title 3 7 Appendix Reference Information A 1 Installing a Firmware Update A 2 Specifications A 4 Part Numbers A 4 Table of Contents 68 519 01 A...

Page 4: ...ii RCP 1000 Table of Contents Table of Contents cont d RCP 1000 Remote Control Panel 1 Chapter One Introduction Features ...

Page 5: ...e output to be centered or sized both horizontally and vertically Horizontal and vertical filtering Provide up to eight levels of horizontal and five levels of vertical filter control These operator selectable filtering controls ensure that no picture detail is dropped Remote operation Can be operated up to 1000 feet 304 8 meters away Power Receives power from the SGS 408 Program and preview input...

Page 6: ...ocedure for installing the SGS 408 6 Attach power cords and plug the SGS 408 seamless switcher input devices and output devices into a grounded AC source 7 Select an input from the RCP 1000 top panel buttons 8 The image should now appear If not ensure that all devices are plugged in and receiving power Check the cabling and make adjustments as needed Select a different input to check for an image ...

Page 7: ...RCP 1000 Installation Installation cont d RCP 1000 Remote Control Panel 3 Chapter Three Operation Top Panel Controls Using the Picture Controls Applying a Switch 2 4 ...

Page 8: ...ton is pressed the resulting switch is not seamless 4 Transition buttons Control the type of switch that will occur between program and preview outputs Cut button Initiates an immediate seamless switch between the program and preview images Take button Initiates the switch selected by the effects buttons Effects buttons Control the effect transition and duration of transition effects The effects c...

Page 9: ... contrast and brightness of an image do the following 1 Press and release the Picture control button until the Cont Bright LED lights 2 To change the contrast rotate the left adjustment knob 3 To change the brightness rotate the right adjustment knob Applying a Switch You can switch the program and preview inputs using a variety of techniques For a description of each technique see the instruction...

Page 10: ... and moving out to the edges of the screen Figure 3 6 Square wipe effects A title can have two effects window or key A title window causes a predefined box in the program image to dissolve to reveal the preview image figure 3 7 The effect is as if the preview image were located behind the program image and a window in the program image opens to show the preview image Figure 3 7 A title effect A ti...

Page 11: ...ot need to press it 3 The title effect will either be window or key When you want the title to begin press the Take button If the title effect is window a portion of the program image dissolves to reveal the preview window If the title effect is key any portion of the preview image which is over half intensity 35V will be displayed with the program image The Take light remains on 4 When you want t...

Page 12: ...an damage IC chips even if you cannot sense the discharge 4 Locate the ICs to be replaced figure A 2 The update kit will list the specific ICs Figure A 2 Locating and replacing ICs 5 Remove the existing chip and set it aside Use a standard IC removal tool 6 Install the new chip Locate a notch or a printed dot on top of the IC Align the notch or dot with the notch on the socket or circuit board Ali...

Page 13: ...on National Safe Transit Association Approvals CE UL FCC Class A MTBF 30 000 hours Warranty 2 years parts and labor Specificationsaresubjecttochangewithoutnotice Part Numbers Extron Part Part Number RCP 1000 60 343 01 SGS 408 60 341 01 ECP 1000 60 344 01 RCP comm cable 25 7 6 m 26 519 01 RCP comm cable 50 15 2 m 26 519 02 RCP comm cable 100 30 5 m 26 519 03 RCP comm cable 300 91 4 m 26 519 04 ECP ...

Reviews: