Installing the PVT CV D and PVT RGB D
The PVT CV D and PVT RGB D can be each installed in a
one-gang electrical wall box with a Decora wall plate cover
(supplied). If a suitable wall box is already installed, follow
steps
5
through
8
below. To install a new wall box, follow steps
1
through
8
below. Underwriters Laboratories (UL) Listed wall
boxes are recommended.
The installation must conform to national and local electrical
codes and to the wall plate’s size requirements.
The following Underwriters Laboratories (UL) requirements
pertain to the installation of the PVT transmitters into a wall or
furniture.
1.
These units are not to be connected to a centralized DC
power source or used beyond their rated voltage range.
2. These units must be installed in UL listed junction boxes.
3.
These units must be installed with conduit in accordance
with National Electrical Code.
Preparing the site and installing the wall box
Choose a location that allows cable runs without interference.
Allow enough depth for both the wall box and the cables. The
box should be at least 2.5" (6.4 cm) deep to accommodate the
connectors and cables. Install the cables into the wall, furniture,
or conduits before installing the wall plate.
1
.
If a wall box is not available to use for a template, use the
dimensions on page A-6 to create a template. If installing
directly into furniture, cut out the center portion of your
template.
2
.
Place the wall box (or your template) against the
installation surface, and mark the opening guidelines.
3
.
Cut out the material from the marked area.
4
.
Insert the wall box into the opening. The box or the wall
plate’s rear connectors should fit easily into the opening.
Enlarge or smooth the edges of the opening if needed.
5
.
Feed cables for the output devices through the opening
and through the wall box punch-out holes, securing them
with cable clamps to provide strain relief.
6
.
Trim back and/or insulate exposed cable shields with heat
shrink to reduce the chance of short circuits.
To prevent short circuits, the outer foil shield can be cut
back to the point where the cable exits the cable clamp.
Both braided and foil shields should be connected to an
equipment ground at the other end of the cable.
2-3
PVT Series (D and AAP models) • Installation