Extron electronics PowerCage 1600 User Manual Download Page 4

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause interference; the user must correct the interference at 
his own expense.

NOTE:

  For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, 

accessibility, and related topics, see the “

Extron Safety and Regulatory Compliance 

Guide

” on the Extron website.

Conventions Used in this Guide

Notifications

The following notifications are used in this guide: 

WARNING:

  Potential risk of severe injury or death. 

AVERTISSEMENT :

 

Risque potentiel de blessure grave ou de mort.

CAUTION:

  Risk of minor personal injury.

ATTENTION :

  Risque de blessure mineure.

ATTENTION:

 

• 

Risk of property damage. 

• 

Risque de dommages matériels.

NOTE:

  A note draws attention to important information.

Specifications Availability

Product specifications are available on the Extron website, 

www.extron.com

.

 

PowerCage 1600 Enclosure User Guide • Conventions

iv

Summary of Contents for PowerCage 1600

Page 1: ...User Guide PowerCage 1600 Enclosure Fiber Optic Products Modular Power Enclosure for Fiber Optic and Twisted Pair Extenders 68 1717 01 Rev E 01 19...

Page 2: ...a 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la pr sence l int rieur du...

Page 3: ...aTools VN Matrix VoiceLift WallVault WindoWall XTP and XTP Systems Registered Service Mark SM S3 Service Support Solutions Trademarks AAP AFL Accu Rate Frame Lock ADSP Advanced Digital Sync Processing...

Page 4: ...t the interference at his own expense NOTE For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and Regulatory...

Page 5: ...oards 3 System Example 4 Installation 5 Enclosure and Rear Panel Features 6 Installing Transmitter and Receiver Boards into the Enclosure 8 Mounting the Unit 10 UL Guidelines for Rack Mounting 10 Rack...

Page 6: ...PowerCage 1600 Enclosure Contents vi...

Page 7: ...1600 is a rack mountable 16 slot enclosure with vents fans and an integrated power supply or redundant power supplies that supports a wide range of Extron fiber optic and twisted pair AV transmitter...

Page 8: ...t number 70 784 01 Thermal management The PowerCage enclosure provides channeled air flow to each board for optimal cooling and reliable operation PowerCage FOX Fiber Optic Extender Boards The fiber o...

Page 9: ...hey transmit and receive high resolution RGBHV RGBS RGsB RsGsBs component video S video and composite video long distances Include the following models PowerCage MTP T 15HD RSA MTP Twisted Pair Transm...

Page 10: ...RGB PowerCage FOX 4G Rx VGA Tx Rx L R AUDIO 1 2 REMOTE RS 232 RS 232 OVER FIBER Tx Rx Tx ALARM Rx OUTPUT RGB PowerCage FOX 4G Rx VGA Tx Rx L R AUDIO 1 2 REMOTE RS 232 RS 232 OVER FIBER Tx Rx Tx ALARM...

Page 11: ...initial installation and subsequent removal and replacement of the boards 2 Mount the enclosure to an equipment rack 3 Connect cables to the transmitter and receiver boards and to input and output dev...

Page 12: ...d IEC power cord NOTE The power supplies and transmitter and receiver boards may be installed or replaced before or after the unit is powered on 2 Main power supply This power supply is included with...

Page 13: ...correspond to these slot numbers NOTES Cover all empty board slots do not leave them open Securely fasten the screws for boards and blank panels A double slot board connects to the lower numbered slot...

Page 14: ...CAUTIONS ATTENTIONS Use ESD precautions when installing a board to avoid damaging it Keep the board in the anti static bag until it is needed Prenez les pr cautions ESD lorsque vous installez une cart...

Page 15: ...57 78 C US LIS TE D 1T 23 I T E Screws 2 per board 1 2 REMOTE RS 232 RS 232 OVER FIBER Tx Rx Tx ALARM Rx OUTPUT RGB Po we rC ag e FO X RG B Tx Rx L R AUDIO Align board and slide into slot Figure 5 Ins...

Page 16: ...g Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropri...

Page 17: ...Tx ALARM Rx VIDEO 1 2 3 4 Tx Rx L R AUDIO 1 2 REMOTE RS 232 RS 232 OVER FIBER Tx Rx Tx ALARM Rx OUTPUT RGB Tx Rx L R AUDIO 5A MA X 100 24 0V 50 60H z 3 U Rack Mount Bracket use four mounting holes Fig...

Page 18: ...Selection Button System Temperature Status LED 6 5 4 2 Figure 7 The PowerCage 1600 Enclosure Front Panel 1 Board status LEDs Comm Power Alarm There is one set of these LEDs for each of the 16 rear pan...

Page 19: ...or the selected board lights NOTES When unit power is cycled removed then restored the serial connection returns to the board in the lowest numbered slot A double slot board connects to the lower numb...

Page 20: ...boards commands and queries cannot be sent to or passed through the MTP boards To communicate with and check some basic information about individual installed transmitter or receiver boards do the fol...

Page 21: ...DVI PowerCage FOX Rx DVI Tx Rx L R AUDIO Slot Number Jumps to Populated Board Number Appropriate LED Lights 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Rear Panel Front Panel N15778 I T E 1T23 Figure 9 Cha...

Page 22: ...port Free Zone F13 PO Box 293666 United Arab Emirates Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal o...

Reviews: