![Extron electronics MTP T 15HD A AAP User Manual Download Page 7](http://html1.mh-extra.com/html/extron-electronics/mtp-t-15hd-a-aap/mtp-t-15hd-a-aap_user-manual_2456747007.webp)
2-3
MTP T 15HD A Architectural Plates • Installation
Both braided and foil shields should be connected to an
equipment ground at the other end of the cable.
7
.
Connect the output device cables to the rear of the MTP
architectural wall plate. See
Rear Panel Features
later in this
manual for connector wiring details.
8
.
Connect input devices (see
Front Panel Features
later in this
manual for connector details), restore the power supply,
and test the wall plate. Make any cabling adjustments
before final installation as the cables will be inaccessible
afterwards
Final installation
After testing and making any adjustments, turn off the power
supply and carefully insert the wall box into the opening.
Attach it with nails or screws, leaving the front edge flush with
the outer wall or furniture surface. See figure 2-1.
N
If attaching the wall box to wood, use four #8 or #10
screws or 10-penny nails. A minimum of 0.5" (1.3 cm)
of screw thread must penetrate the wood.
N
If attaching the wall box to metal studs or furniture,
use four #8 or #10 self-tapping sheet metal screws or
machine bolts with matching nuts.
Installation
Cable
Cable
Clamp
Wall Stud
Screws
or Nails
Wall Stud
Installation
Cable
Cable
Clamp
Screws
or Nails
Figure 2-1 — Installing the wall box
If installing an MTP T 15HD A WM, mount the faceplate directly
to the box.
If installing an MTP T 15HD A D, mount it directly to the wall
box, then attach the Decora wall plate, as show in figure 2-2.
Restore the power supply.
2-2
Installation
MTP T 15HD A Architectural Plates • Installation
Installing the MTP T 15HD A WM and
MTP T 15HD A D
The MTP T 15HD A WM and MTP T 15HD A D can be installed
in a one-gang electrical wall box, with the MTP T 15HD A D
fitting into a Decora wall plate cover (supplied). If a suitable
wall box is already installed, follow steps 5 through 8 below. To
install a new wall box, follow all the steps below. Underwriters
Laboratories (UL) Listed wall boxes are recommended.
The installation must conform to national and local electrical
codes and to the wall plate’s size requirements.
The following Underwriters Laboratories (UL) requirements
pertain to the installation of the MTP T 15HD A architectural
series into a wall or furniture.
1. These units are not to be connected to a centralized DC power
source or used beyond their rated voltage range.
2. These units must be installed in UL listed junction boxes.
3. These units must be installed with conduit in accordance with
the National Electrical Code
Preparing the site and installing the wall box
Choose a location that allows cable runs without interference.
Allow enough depth for both the wall box and the cables. The
box should be at least 2.5" (6.4 cm) deep to accommodate the
connectors and cables. Install the cables into the wall, furniture,
or conduits before installing the wall plate.
1
.
If a wall box is not available to use for a template, use the
template on page 2-9. If installing directly into furniture,
cut out the center portion of the template.
2
.
Place the template (or the wall box) against the installation
surface, and mark the guidelines for the the opening
3
.
Cut out the material from the marked area.
4
.
Insert the wall box into the opening. The box or the wall
plate’s rear connectors should fit easily into the opening.
Enlarge or smooth the edges of the opening if needed.
5
.
With the power supply disconnected, feed cables for the
output devices through the opening and through the wall
box punch-out holes, securing them with cable clamps to
provide strain relief.
6
.
Trim back and/or insulate exposed cable shields with heat
shrink to reduce the chance of short circuits.
To prevent short circuits, the outer foil shield can be cut
back to the point where the cable exits the cable clamp.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203