Extron electronics MTP T 15HD A AAP User Manual Download Page 7

2-3

MTP T 15HD A Architectural Plates • Installation

 

 

Both braided and foil shields should be connected to an 

equipment ground at the other end of the cable.

7

Connect the output device cables to the rear of the MTP 

architectural wall plate.  See 

Rear Panel Features

 later in this 

manual for connector wiring details.

8

Connect input devices (see 

Front Panel Features

 later in this 

manual for connector details), restore the power supply, 

and test the wall plate.  Make any cabling adjustments 

before final installation as the cables will be inaccessible 

afterwards

Final installation

After testing and making any adjustments, turn off the power 

supply and carefully insert the wall box into the opening. 

Attach it with nails or screws, leaving the front edge flush with 

the outer wall or furniture surface. See figure 2-1.

N

 

If attaching the wall box to wood, use four #8 or #10  

screws or 10-penny nails.  A minimum of 0.5" (1.3 cm) 

of screw thread must penetrate the wood.

N

 

If attaching the wall box to metal studs or furniture, 

use four #8 or #10 self-tapping sheet metal screws or 

machine bolts with matching nuts.

Installation 
Cable

Cable 
Clamp

Wall Stud

Screws 

or Nails

Wall Stud

Installation 
Cable

Cable  
Clamp 

Screws  

or Nails 

Figure 2-1 — Installing the wall box

If installing an MTP T 15HD A WM, mount the faceplate directly 

to the box.  
If installing an MTP T 15HD A D, mount it directly to the wall 

box, then attach the Decora wall plate,  as show in figure 2-2.
Restore the power supply.

2-2

Installation

MTP T 15HD A Architectural Plates • Installation

Installing the MTP T 15HD A WM and  

MTP T 15HD A D

The MTP T 15HD A WM  and MTP T 15HD A D can be installed 

in a one-gang electrical wall box, with the  MTP T 15HD A D 

fitting into a Decora wall plate cover (supplied).  If a suitable 

wall box is already installed, follow steps 5 through 8 below.  To 

install a new wall box, follow all the steps below.  Underwriters 

Laboratories (UL) Listed wall boxes are recommended.
The installation must conform to national and local electrical 

codes and to the wall plate’s size requirements.
The following Underwriters Laboratories (UL) requirements 

pertain to the installation of the MTP T 15HD A architectural 

series into a wall or furniture.
1. These units are not to be connected to a centralized DC power  

     source or used beyond their rated voltage range.
2. These units must be installed in UL listed junction boxes.
3. These units must be installed with conduit in accordance with     

    the National Electrical Code

Preparing the site and installing the wall box 

Choose a location that allows cable runs without interference.  

Allow enough depth for both the wall box and the cables.  The 

box should be at least 2.5" (6.4 cm) deep to accommodate the 

connectors and cables.  Install the cables into the wall, furniture, 

or conduits before installing the wall plate.  

1

If a wall box is not available to use for a template, use the 

template on page 2-9.  If installing directly into furniture, 

cut out the center portion of the template.

2

Place the template (or the wall box) against the installation 

surface, and mark the guidelines for the the opening

3

Cut out the material from the marked area.

4

Insert the wall box into the opening.  The box or the wall 

plate’s rear connectors should fit easily into the opening.  

Enlarge or smooth the edges of the opening if needed.

5

With the power supply disconnected, feed cables for the 

output devices through the opening and through the wall 

box punch-out holes, securing them with cable clamps to 

provide strain relief.

6

Trim back and/or insulate exposed cable shields with heat 

shrink to reduce the chance of short circuits.

 

To prevent short circuits, the outer foil shield can be cut 

back to the point where the cable exits the cable clamp.

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Summary of Contents for MTP T 15HD A AAP

Page 1: ...sia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Kyodo Building 16 Ichibancho Chiyoda ku Tokyo 102 0082 Japan 81 3 3511 7655 F...

Page 2: ...heSpannungen dienichtisoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Sicherheit...

Page 3: ...the MTP T 15HD A AA P 2 4 Connections and Setting s 2 5 Front panel feature s 2 5 Rear panel feature s 2 6 TP cable terminatio n 2 8 Templat e 2 9 Application Diagrams 2 10 Appendix A Specifications A...

Page 4: ...troduction About the MTP Transmitters MTP T 15HD A Architectural Plates This page was deliberately left blank im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce...

Page 5: ...d transmitter Pre Peak switch positions using Extron Enhanced Skew Free A V UTP cable or UTP CAT 5 cable terminated with CAT 5 rated connectors MTP T 15HD A Architectural Plates Introduction Introduct...

Page 6: ...ne gang electrical wall box AUDIO IN MTP T 15HD A COMPUTER IN About the MTP T 15HD A D The MTP T 15HD A D Twisted Pair Transmitter is a wall or furniture mountable version of the MTP T 15HD A that fit...

Page 7: ...8 below To install a new wall box follow all the steps below Underwriters Laboratories UL Listed wall boxes are recommended The installation must conform to national and local electrical codes and to...

Page 8: ...P UTE R IN Connections and Settings C Do not connect these devices to a computer data or telecommunications network Front panel features The front panel features are the same on all the MTP T 15HD A a...

Page 9: ...A Ridges Smooth A A Figure 2 8 Power connector wiring C Power supply voltage polarity is critical Incorrect voltage polarity can damage the power supply and the MTP Identify the power cord negative le...

Page 10: ...are not as secure in the direct insertion connectors and could be pulled out N Do not tin the power supply leads before installing in the direct insertion connector Tinned wires are not as secure in t...

Page 11: ...IN SVGA Compatible Computer w Audio Enhanced Skew Free UTP Cable RG B PEA KIN G LEV EL M TP SER IES MTP R 15HD A Application Diagrams Enhanced Skew Free UTP Cable RG B PE AK ING LE VE L M TP SER IES M...

Page 12: ...dBu 1 23 Vrms 10 dBV 316 mVrms Maximum level 18 dBu unbalanced at 1 THD N Audio output local stereo output see receiver s specifications for remote end specs Number signal type 1 set of proprietary a...

Page 13: ...ccessories Cables various lengths Part number VGA with audio cables male to male 26 490 xx UTP23SF 4 non plenum 26 569 xx UTP23SF 4P plenum 26 570 xx Cables Bulk UTP23SF 4 1000 non plenum 22 141 03 UT...

Page 14: ...the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined t...