Extron electronics MTP C7 T 15HD RS User Manual Download Page 3

 

iii

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 
of the FCC Rules. Operation is subject to the following two conditions: 

1. 

This device may not cause harmful interference.

2. 

This device must accept any interference received, including interference that may cause undesired operation. 

The Class A limits are designed to provide reasonable protection against harmful interference when the equipment 
is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy 
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which 
case the user will be required to correct the interference at his own expense.

NOTE:

   This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the 

unit to ensure compliance with FCC emissions limits.
For more information on safety guidelines, regulatory compliances, EMI/EMF compliance, accessibility, and 
related topics, 

click here

.

In this user guide, the following are used:

TIP:

  A tip provides a suggestion to make setting up or working with the device easier.

NOTE:

  A note draws attention to important information.

CAUTION:

  A caution warns of things or actions that might damage the equipment.

WARNING:

  A warning warns of things or actions that might cause injury, death, or other severe consequences.

Copyright

© 2011  Extron Electronics. All rights reserved.

Trademarks

All trademarks mentioned in this guide are the properties of their respective owners.

Summary of Contents for MTP C7 T 15HD RS

Page 1: ...68 925 02 Rev F 08 11 High Resolution Video and Serial Link MTP Transmitters and Receivers MTP 15HD RS Series User Guide Twisted Pair...

Page 2: ...machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Si...

Page 3: ...a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE This unit was tested with shielded cables on the...

Page 4: ...Twisted Pair Cable Termination 14 Skew Delay Compensation 15 SEQ Receiver Skew Compensation 15 Non SEQ Receiver Skew Compensation 15 Reference Information 16 Specifications 16 Part Numbers Optional A...

Page 5: ...products that are compatible with Extron STP201 or CAT 7 cable only In this guide any reference to these products refers to either family unless explicitly stated NOTE For clarity and where applicabl...

Page 6: ...NOTE If there is only one receiver in the system you can shift a jumper in that receiver see Receiver Jumpering on page 5 to allow bidirectional RS 232 communications and change a DIP switch setting s...

Page 7: ...page 10 using Extron Enhanced Skew Free A V UTP cable STP201 cable or CAT 5 5e 6 or 7 cable terminated with RJ 45 connectors NOTES The non C7 transmitter and receiver are designed for and perform best...

Page 8: ...0 90 m 400 120 m 2048x1080 250 75 m 300 90 m 300 90 m 400 120 m HDTV 720p 250 75 m 300 90 m 400 120 m 500 150 m HDTV 1080i 250 75 m 300 90 m 300 90 m 400 120 m HDTV 1080p 250 75 m 300 90 m 300 90 m 40...

Page 9: ...jumper JMP1 on the serial data top board and shift the jumper to bridge the jumper block see figure 2 below 4 Place the top cover back into place 5 Reinstall the four screws removed in step 2 If any...

Page 10: ...all power sources and signal cables are disconnected 2 If necessary configure the receiver jumpers see Receiver Jumpering on page 5 3 If applicable mount the MTPs see Mounting on page 20 4 Connect th...

Page 11: ...e displayed image Adjust the knob while viewing the displayed image to set the level that provides the best picture quality NOTE For best results when using an RL receiver connect a load to the buffer...

Page 12: ...e the video signal that is selected by the Select button d for skew adjustment using the Delay control f The LED of the selected color flashes when skew compensation for the selected video signal has...

Page 13: ...ection on page 13 before wiring the connector b Input video connector Connect a computer video source to this 15 pin HD connector for high resolution video input see figure 5 5 1 15 11 6 10 Female Fig...

Page 14: ...er the wires can be easily pulled out even if tightly fastened by the captive screws Do not tin the wires Tinned wire does not hold its shape and can become loose over time e Pre Peak switch The Pre P...

Page 15: ...uffered output connector of an RL receiver to this RJ 45 female connector c Buffered output connector Connect one end of a TP cable to this female RJ 45 connector Connect the free end of the same TP c...

Page 16: ...onent S video Composite Figure 8 Receiver DIP Switch Settings z z Sync on Green SOG switch Set this switch up for RGsB video when the input is RGBHV or RGBS or down to output RGBHV RsGsBs or RGBS vide...

Page 17: ...itable for use in air handling spaces or in wall cavities The power supply is to be located within the same vicinity as the Extron A V processing equipment in an ordinary location Pollution Degree 2 s...

Page 18: ...ee A V UTP cable use the TIA EIA T568A standard only Figure 10 TP Cable Termination Diagram NOTES RJ 45 termination with CAT 5 5e or 6 cable for non C7 units only or STP201 or CAT 7 cable for C7 units...

Page 19: ...l for determining skew 3 Adjust the leftmost video signal as follows NOTE The SEQ receiver cannot shift the rightmost video image to the left a Use a small screwdriver to press and release the Select...

Page 20: ...B Y of component video 0 3 Vp p for C of S video Minimum maximum levels 0 3 V to 1 45 Vp p Impedance 75 ohms Horizontal frequency 15 kHz to 130 kHz Vertical frequency 30 Hz to 150 Hz Return loss 30 dB...

Page 21: ...captive screw connector Receivers 1 set of proprietary signals on a female RJ 45 jack Serial control port output input MTP C7 T 15HD RS MTP T 15HD RS 1 set of proprietary signals on a female RJ 45 jac...

Page 22: ...d labor NOTE All nominal levels are at 10 NOTE Specifications are subject to change without notice Part Numbers Optional Accessories Cables and Connectors Part Numbers MTP Transmitter and Receivers fo...

Page 23: ...escription Part Number VGA connector cable 26 238 xx SYM BNC Female Mini High Resolution cable 26 531 xx Extron Enhanced Skew Free A V UTP cable cut various lengths 26 569 xx Extron Enhanced Skew Free...

Page 24: ...r multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore install the equipment in an environment compatible with the...

Page 25: ...e unit on a rack shelf follow the instructions provided with the shelf accessories Back of the Rack Mounting Procedure The MTP can be mounted to the rear of a rack using the Extron MBB 100 1 8 and 1 4...

Page 26: ...ive please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 Europe 31 33 453 4040 Asia 65 6383 4400 Japa...

Reviews: