![Extron electronics MTP C7 T 15HD RS User Manual Download Page 14](http://html1.mh-extra.com/html/extron-electronics/mtp-c7-t-15hd-rs/mtp-c7-t-15hd-rs_user-manual_2456739014.webp)
d
RS-232 connector
—
Connect a serial communications port to this 3.5 mm, 3-pole
captive screw connector for bidirectional RS-232 communication. Wire the connector as
shown in figure 6.
Ground
Tx
Rx
Gnd
Receive
Transmit
Connected RS-232
Device Pins
MTP
Pins
Figure 6.
RS-232 Connector Wiring
NOTES:
•
By default, the RS-232 portion of the TP link is unidirectional only from
the transmitter to the receiver. If there is only one receiver in a system,
a jumper within the receiver allows the RS-232 communication to be
bidirectional (see "
Receiver Jumpering
" on page 5).
•
The length of the exposed wires in the stripping process is critical. The
ideal length is 3/16 inches (5 mm). If the exposed section is longer, the
exposed wires may touch, causing a short circuit between them. If it is
shorter, the wires can be easily pulled out, even if tightly fastened by the
captive screws.
•
Do not tin the wires. Tinned wire does not hold its shape and can
become loose over time.
e
Pre-Peak switch
—
The Pre-Peak switch alters the TP signal output to correct for
long cable runs. See the
table
on page 4 for suggested switch settings based on the
transmitted video format and transmission distance.
f
Output connector
—
Connect one end of a TP cable to this RJ-45 female connector
on the transmitter. Connect the free end of the same TP cable to the RJ-45 female
connector on the receiver. See "
Twisted Pair Cable Termination
" on page 14 to wire
the RJ-45 connectors.
CAUTION:
Do not connect these devices to a computer data or
telecommunications network.
NOTES:
•
The non-C7 transmitters and receivers
will not work properly
with
STP201 or CAT 7 STP cable.
•
The C7 transmitters and receivers
will work properly
only with STP201
or CAT 7 STP cable.
MTP 15HD RS Series • Installation and Operation