Step 4 — Remote connections
a. Contact closure connectors —
Connect an Extron
MMX 32 AAP or MMX 32 MAAP contact closure
remote control panel to these two 5-pole captive
screw connectors to provide control for outputs
1 and 2. Connect the 5 V and Gnd (-) 2-pole captive
screw connector on the AAP or MAAP to either of
these connectors.
b. RS-232 connector —
Connect an RS-232 control module to this 3-pole captive screw
connector (see image above) to allow remote control using the Extron Simple Instruction
Set
™
(SIS
™
) or the Extron Universal Switcher Control Program.
N
For full SIS commands and details of the Universal Switcher Control Program, refer to the
MMX 32 VGA MTP Users’s Guide.
Step 5 — Power
Plug the included external 12 VDC power supply into the 2-pole
captive screw connector. Wire the connector as shown at right.
Step 6 — Pre-Peaking and sync selection
P
re-Peaking —
To compensate for signal loss over long cable runs, set the DIP
switch position (up = on, down = off) as shown in the table below:
Video Format
Cable length
Signal quality at max.
distance
Pre-Peak Off
Pre-Peak On
High
Variable
Composite, S-video,
Component
800 ft (245 m) 1000 ft (300 m)
640 x 480
<300 ft (90 m)
>350 ft (105 m)
700 ft (215 m) 750 ft (230 m)
800 x 600
<300 ft (90 m)
>350 ft (105 m)
550 ft (165 m) 650 ft (200 m)
1024 x 760
<300 ft (90 m)
>350 ft (105 m)
500 ft (150 m) 600 ft (185 m)
1280 x 1024
<250 ft (75 m)
>300 ft (90 m)
350 ft (105 m) 450 ft (135 m)
1600 x 1200
<250 ft (75 m)
>300 ft (90 m)
300 ft (90 m)
450 ft (135 m)
Sync selection
—
To select either bi-level sync or tri-level sync on output 2, set the sync DIP
switch to the desired setting (up = tri-level sync, down = bi-level sync).
N
Set when transmitting tri-level sync component video.
SECTION A–A
A
A
Power Supply
Output Cord
Ridges
Smooth
3/16"
(5 mm) Max.
2-Pole Captive
Screw Connector
Tie Wrap
Setup Guide — MMX 32 VGA MTP cont’d
REMOTE
RS-232
+5V
2
1
1 2 3
Tx Rx
CONT
A
C
T
Output 1 control
Output 2 control
RS-232
connection
SYNC -
TRI
PRE PEAK - ON
2