MKP 2000 • Installation
12
Extron Control System Comm-Link cable
Wire specifications for Extron Comm-Link cable (see figure 13) are as follows:
•
A (red) = 18 American Wire Gauge (AWG)
•
B (violet or blue) = 22 AWG (grouped and shielded)
•
C (white) = 22 AWG
•
D (drain) = 24 AWG
•
E (black) = 18 AWG
NOTE:
Comm-Link cable was designed for use with MKP control panels.
SuperFlex Plenum
Jacket
Fiber Wrap
Two 22 AWG
(White and Violet or Blue)
One 24 AWG
Tinned Copper Drain Wire
(foil-shielded group)
B, C
D
Two 18 AWG
(Red and Black)
A, E
Figure 13.
Extron Comm-Link Cable
For RS- 232 pin assignments, see figure 14.
Pin
Switcher RS-232
MKP RS-232
1
–
–
2
Tx
Rx
3
Rx
Tx
4
–
–
5
Gnd
Gnd
6
–
–
7
–
–
8
–
–
9
–
–
Figure 14.
RS-232 Cross-connection Table
TP Cable Termination and Recommendations
It is vital that you use the correct Ethernet cables, and that they be properly terminated with
the correct pinout. Ethernet links use Category (CAT) 5e or CAT 6, unshielded twisted pair
(UTP) or shielded twisted pair (STP) cables, terminated with RJ-45 connectors. Ethernet
cables are limited to a length of 328 feet (100 m).
ATTENTION:
•
Do not use standard telephone cables. Telephone cables do not support Ethernet
or Fast Ethernet.
•
Ne pas utiliser de câbles téléphone standard. Les câbles de téléphone ne sont pas
compatibles avec les liaisons Ethernet ou Fast Ethernet.
•
Do not stretch or bend cables. This can cause transmission errors.
•
Ne pas étirer ou plier les câbles. Cela pourrait provoquer des erreurs de
transmission.
figure 13
figure 14