MKP 2000 • Installation
11
An MKP control panel can be directly connected to any Ethernet-enabled matrix switcher
via the switcher Ethernet port (see figure 11) using a TP (network) cable that is wired as a
crossover cable (see
TP Cable Termination and Recommendations
on page 12, to
properly wire the cable).
MKP 2000
Crossover
Cable
LAN Port
Matrix Switcher
MKP 2000
4
5
6
1
2
3
7
8
9
BACK
0
CANCEL
INPUT
OUTPUT
TAKE
I
N
P
U
T
S
CONTROL
O
U
T
P
U
T
S
I/O
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
MAV 2400 SERIES SWITCHER
Figure 11.
Direct MKP Connection Via the LAN Port
Any number of control panels can be connected, as part of a network, to any Ethernet-
enabled matrix switcher via the switcher Ethernet port (see figure 12). All TP cables in this
example are wired as patch (straight-through) cables.
Ethernet
MKP 2000
MKP 2000
MKP 2000
PC
Patch
Cable
Patch
Cable
Matrix Switcher
MKP 2000
4
5
6
1
2
3
7
8
9
BACK
0
CANCEL
INPUT
OUTPUT
TAKE
MKP 2000
4
5
6
1
2
3
7
8
9
BACK
0
CANCEL
INPUT
OUTPUT
TAKE
MKP 2000
4
5
6
1
2
3
7
8
9
BACK
0
CANCEL
INPUT
OUTPUT
TAKE
I
N
P
U
T
S
CONTROL
O
U
T
P
U
T
S
I/O
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
MAV 2400 SERIES SWITCHER
Figure 12.
Network MKP Connection Using the LAN Port
RS-232 Cable Termination
Each MKP control panel has two RS-232 ports that are connected using 3.5 mm, 3-pole
direct insertion connectors. Wire the connectors as follows:
NOTE:
The total cable length between an MKP control panel and a matrix switcher
should not exceed 100 feet (30 m).
1.
Choose a cable such as the Extron Comm-Link cable (see
for the wire specifications for Comm-Link cable). Colors may vary from this example.
2.
Trim approximately 1.5 inches (3.8 cm) of the cable jacket to expose the four insulated
wires and a bare drain wire (silver-colored).
3.
Cut off the foil shield and discard it.
4.
Strip ¼ inch (0.6 cm) of insulation from any three of the four wires (not including the
drain [unshielded] wire).
5.
Twist the strands of each wire, insert the strands into the direct insertion connector, and
tighten the captive screws.
figure 11
figure 12
Summary of Contents for MKP 2000
Page 1: ...User Guide MKP 2000 Matrix Switchers Remote Control Panel 68 971 01 Rev E 01 19 ...
Page 6: ......
Page 8: ...MKP 2000 Contents viii ...
Page 56: ......