Extron electronics IP Link IPL EXP 200 User Manual Download Page 3

Copyright and Trademark Notices

Copyright

© 2021  Extron. All rights reserved. 

www.extron.com

Trademarks

All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks (®), registered service marks (

SM

), and trademarks (™) are the property of RGB Systems, Inc. or Extron (see the current list 

of trademarks on the 

Terms of Use

 page at 

www.extron.com

):

Registered Trademarks

 

(®)

Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, eLink, Flat Field, FlexOS, Glitch Free, Global Configurator, 
Global Scripter, GlobalViewer, Hideaway, HyperLane, IP Intercom, IP Link, Key Minder, LinkLicense, LockIt, MediaLink, MediaPort, NAV,  
NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, ShareLink, Show Me, SoundField, SpeedMount, SpeedSwitch, StudioStation, 
System 

I

ntegrator

, TeamWork, TouchLink, V‑Lock, VN‑Matrix, VoiceLift, WallVault, WindoWall, XPA, XTP, XTP Systems, and ZipClip

Registered Service Mark

(SM)

 :  

S3 Service Support Solutions

Trademarks

 

(™)

AAP, AFL (Accu‑RATE Frame Lock), ADSP (Advanced Digital Sync Processing),  AVEdge, CableCover, CDRS (Class D Ripple Suppression), Codec 
Connect, DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), Driver Configurator, DSP Configurator, DSVP (Digital Sync  
Validation Processing), EQIP, Everlast, FastBite, Flex55, FOX, FOXBOX, IP Intercom HelpDesk, MAAP, MicroDigital, Opti‑Torque, PendantConnect, 
ProDSP, QS‑FPC (QuickSwitch Front Panel Controller), Room Agent, Scope‑Trigger, SIS, Simple Instruction Set, Skew‑Free, SpeedNav, Triple‑Action 
Switching, True4K, True8K, Vector

 4K, WebShare, XTRA, and ZipCaddy

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IP Link IPL EXP 200

Page 1: ...IPL EXP I O Series Control System Expansion Interfaces 68 3490 01 Rev A 08 21 User Guide IP Link Pro xi Products...

Page 2: ...Safety Instructions...

Page 3: ...ault PowerCage PURE3 Quantum ShareLink Show Me SoundField SpeedMount SpeedSwitch StudioStation SystemIntegrator TeamWork TouchLink V Lock VN Matrix VoiceLift WallVault WindoWall XPA XTP XTP Systems an...

Page 4: ...interference must be corrected at the expense of the user NOTE For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Sa...

Page 5: ...device responses mentioned in this guide the character 0 is used for the number zero and O is the capital letter o Computer responses and directory paths that do not have variables are written in the...

Page 6: ......

Page 7: ...s a Key to Extron specific File Names 38 Secure Sockets Layer SSL Certificates 39 IEEE 802 1X Certificates 40 Certificate File Requirements 40 Private Key File Requirements 41 SNMP 41 Introduction 1 B...

Page 8: ...Series Contents vi Firmware Updates 42 Determining the Firmware Version 42 Using Toolbelt Software 42 Using a Browser 42 Updating the Firmware 43 Locating and Downloading the Firmware 43 Installing F...

Page 9: ...tware help files describe how to use each program to download drivers add AV devices to a configuration configure basic functions and set up schedules macros e mail alerts touchpanel button configurat...

Page 10: ...els Extron NBP Network Button Panels and IPL EXP expansion interfaces Most IPCP Pro xi Series control processor models except the IPCP Pro S1 xi and the IPL EXP 200 also support Extron eBUS button pan...

Page 11: ...ides 12 VDC and 24 VDC output ports that are used in conjunction with the digital I O ports All other models accept PoE or PoE input on the LAN PoE port Network and configuration features Global compa...

Page 12: ...x G REMOTE LAN PoE IPL EXP S5 Tx Rx G COM Tx Rx G RESET 1 2 Tx Rx G Tx Rx G 3 4 Tx Rx G 5 Ethernet TLP Pro 1220MG 1 2 PWR PWR 3 PoE OUT PoE OUT G Tx Rx G Tx Rx COM 2 COM 3 RELAYS 2 1 4 3 C C AV LAN LA...

Page 13: ...tion to the control processor To obtain Extron control product software you must have an Extron Insider account and contact an Extron support representative Extron provides training to our customers o...

Page 14: ...ecklist Get Ready Familiarize yourself with the features of the IPL EXP Expansion Iinterface see Front Panel Features on page 10 and Ports Addressing and Connections on page 13 and of any IPCP Pro xi...

Page 15: ...IEEE 802 1X security obtain a PEM encoded security certificate and private key see IEEE 802 1X Certificates on page 40 from your IT department Mount and Cable All Devices Mount the unit to a rack or...

Page 16: ...under what circumstances Configure ports on the control processor Select device drivers and link them to each serial IR serial or Ethernet port Select settings serial protocol relay behavior digital I...

Page 17: ...al guide to setting up the expansion interface for network use Open the Toolbelt software from within Global Configurator GC Professional or GC Plus mode or as the stand alone application Start Device...

Page 18: ...7 8 12V24V G 12 VDC 24 VDC 19W MAX TOTAL LAN PoE LAN PoE IPL EXP S2 Tx Rx G COM Tx Rx G RESET 1 2 LAN PoE IPL EXP S5 Tx Rx G COM Tx Rx G RESET 1 2 Tx Rx G Tx Rx G 3 4 Tx Rx G 5 LAN PoE IPL EXP 200 V S...

Page 19: ...it for installation procedures and see the UL rack mounting guidelines below for safe installation Then securely mount the control system expansion interface and other devices and attach cables using...

Page 20: ...EXP To attach the EXP to the ZipClip 200 mounting clip 1 Insert the bottom of the EXP down into the clip starting with one end 2 Pivot the other end down and press until the clip snaps into place To r...

Page 21: ...ate side facing the mounting surface of the furniture and with the tab accessible from the front of the furniture 2 Insert the EXP into the ZipClip 2 as described previously and press to snap it into...

Page 22: ...on ou dans les cavit s murales The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI NFPA 70 article 725 and the Canadian Electrical Code part 1...

Page 23: ...s the IPL EXP RIO8 enters the limit mode The Limit condition is indicated within Global Configurator and the ports are operational If you have configured the unit to do so the IPL EXP RIO8 can issue a...

Page 24: ...19 watts All power output ports shut off Power will be restored after you correct the excessive power draw from the connected devices Sensor LED accessory or similar item Sensor LED accessory or simi...

Page 25: ...M RS 232 Select protocol via software COM port default protocol 9600 baud 8 data bits 1 stop bit no parity no flow control NOTE The 3 pole COM ports support software flow control only Serial COM Ports...

Page 26: ...s configure the settings and IP addresses via Toolbelt See the help file for Global Configurator or Toolbelt for basic information on configuration See the diagram on the next page and see the followi...

Page 27: ...e unit is powered and operational Ethernet Link LED Activity LED 100 Mbps Connection Network is active Data is being sent received or TCP IP Network LAN Ethernet Default protocol public ports Default...

Page 28: ...t options IR 30 kHz to 300 kHz with or without carrier signals Unidirectional RS 232 or Figure 9 Wiring the IR Serial Port Serial control Connect the IR S port to the serial control receive Rx and gro...

Page 29: ...All relays are normally open Relay LEDs Light when the corresponding relays are activated tied to GND closed Figure 10 Cabling Relay Ports These relay contacts may be used to control any equipment as...

Page 30: ...to Monitor or trigger events and functions toggle relays issue commands send e mail once configured Power LEDs or other devices that accept a TTL signal Switch Sensor 2 1 12V 24V G Heat Shrink Over Sh...

Page 31: ...ensor connection Control Signal Ground 5 0 V 1k ohms SW 2 SW 1 Digital I O GND Voltage Protection CTL Occupancy Sensor Figure 12 Digital I O Digital Input Application Occupancy Sensor Without Pull up...

Page 32: ...To activate LEDs incandescent lights or other devices that accept a TTL signal or to provide contact closure control for projector lifts motorized screens room or light switches via an Extron IPA T R...

Page 33: ...ED External 5 VDC Power Source Resistor R Figure 14 Digital I O Digital Output Application LED and External 5 VDC Power Source Without Pull up To determine the value of the current limiting resistor i...

Page 34: ...ther device via its contact closure input port Connect the digital I O port to the contact input port of another device such as an Extron DTP transmitter When activated the digital I O digital output...

Page 35: ...ogy Reference Guide for the recommended distance from the expansion interface or control processor to the last eBUS device and maximum quantity of devices per control processor The IPL EXP can provide...

Page 36: ...G S S V G S S V Powered eBUS device s eBUS Connections Connect up to four 4 eBUS devices to the eBUS distribution hub EBDB MINI Wire the connectors the same at both ends ATTENTION Do NOT connect the...

Page 37: ...Universal Boot Code reset mode and replace firmware 1 On the IPL EXP expansion interface hold down the recessed Reset button while applying power to the unit Keep holding the button down until the Res...

Page 38: ...reset the unit to all factory default settings 1 Hold down the Reset button until the Reset or Power LED blinks once at 3 seconds twice at 6 seconds and three times at 9 seconds 2 Release and press t...

Page 39: ...d and controlled via a host computer connected to the same network as the control processor see LAN PoE and LAN PoE Ethernet connectors and LEDs starting on page 18 for details about LAN port and cabl...

Page 40: ...interfaces or button panels if used to the project Import GUI layouts and configure the touchpanels or other interfaces Test the system make adjustments finalize configuration Save the project Build...

Page 41: ...account and contact an Extron support representative Extron provides training to our customers on how to use the software For Global Configurator Professional you must first attend Extron training pas...

Page 42: ...download a driver for a specific device Via links from search results 1 Type the specific name of the software package such as Global Configurator or GUI Designer into the Search field in the upper r...

Page 43: ...r panel features and covers basic hardware installation See Front Panel Features on page 10 and Ports Addressing and Connections on page 13 in this guide for features and settings for the ports you ar...

Page 44: ...ecks the power load If the total load power draw is now within safe limits the unit automatically re enables the ports Within Global Configurator the port status returns to normal it is no longer in t...

Page 45: ...rt does not exceed 250 mA eBUS Connections and Configuration Verify that the eBUS ports are wired correctly and that ground earthing wires are connected to the ground pins on every device in the syste...

Page 46: ...l processor A License Information window opens To view a copy of a listed package license in the License Information window click the link in the License column for the relevant package This opens a c...

Page 47: ...OpenSSL certificate encodings such as pem Privacy enhanced Electronic Mail and der Distinguished Encoding Rules file types PEM file types are ASCII encoded and are the required format for uploading to...

Page 48: ...rol system NOTES You must run Toolbelt as an administrator Machine certificates require a private key file which can be encrypted Certificate File Requirements PEM Privacy enhanced Electronic Mail fil...

Page 49: ...nagement information between network devices It helps in monitoring of operations and factors such as packet usage memory usage remote password resets and collection of error information An informatio...

Page 50: ...ee the Hardware Features and Installation section starting on page 6 the Software Based Configuration and Control section starting on page 31 and the IPL EXP I O Series Setup Guide Using Toolbelt Soft...

Page 51: ...cutable installer file exe from the website and run the installer program The program stores the firmware file on the PC in C Program Files x86 Extron Firmware or C Program Files Extron Firmware withi...

Page 52: ...oor South Tower 160 Jan Smuts Avenue Rosebank 2196 South Africa This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnorm...

Reviews: