1. 

Decide where the FPC 6000 will be mounted.

2. 

Use the four provided rack-mounting screws to secure the FPC 6000 to any standard 
equipment rack or control console. Follow the instructions in the “Underwriters Laboratories 
(UL) Guidelines for Rack Mounting” (see the next page) to ensur
e the rack is mounted safely.

Underwriters Laboratories (UL) Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of the 
FPC 6000 in a rack:

• 

Elevated operating ambient temperature

 — If the unit is installed in a closed or multi-

unit rack assembly, the operating ambient temperature of the rack environment may be 
greater than room ambient temperature. Therefore, install the equipment in an environment 
compatible with the maximum ambient temperature (Tma: +104 °F, +40 °C) specified by 
Extron.

• 

Reduced air flow

 — Install the equipment in the rack so that the equipment gets adequate 

air flow for safe operation.

• 

Mechanical loading

 — Mount the equipment in the rack so that uneven mechanical 

loading does not create a hazardous condition.

• 

Circuit overloading

 — Connect the equipment to the supply circuit and consider the 

effect that circuit overloading might have on overcurrent protection and supply wiring. 
Give appropriate consideration to the equipment nameplate ratings when addressing this 
concern.

• 

Reliable earthing (grounding)

 — Maintain reliable grounding of rack-mounted equipment. 

Pay particular attention to supply connections other than direct connections to the branch 
circuit (such as the use of power strips).

Wall Mounting the FPC 6000

The FPC 6000 can also be wall-mounted, either using the Extron BB 700M wall box or directly 
into drywall. Some local building codes require the touchpanel to be mounted in a wall box. To 
use the BB 700M, see the 

TLP Pro 1220MG, TLP Pro 1520MG, and TLP Pro 1720MG Setup 

Guide

, at 

www.extron.com

. If the wall box is not required by local building codes, you can 

mount the touchpanel directly into drywall. 

ATTENTION:

• 

Do not install the FPC 6000 in a fire resistant rated wall or partition assembly.

• 

Ne pas installer le FPC 6000 dans un mur résistant au feu ou une cloison.

• 

All structural steps and electrical installation must be performed by qualified personnel 
in accordance with local and national building codes and electrical codes.

• 

Toute étape structurelle et installation électrique, doit être effectuée par un personnel 
qualifié, conformément aux codes du bâtiment, aux codes incendie et sécurité, et 
aux codes électriques, locaux et nationaux.

 

FPC 6000 • Mounting

7

Summary of Contents for FPC 6000

Page 1: ... 20 Input 17 17 Input 18 18 Input 23 23 Input 24 24 Input 21 21 Input 22 22 Input 26 26 Input 28 28 Input 25 25 Input 27 27 Input 30 30 Input 32 32 Input 29 29 Input 31 31 I O INFORMATION Viewing Mode Inputs Outputs 1 2 3 4 5 6 7 8 9 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Output 9 31 Input 31 Tied Outputs Selected Input SFP Module Status FINI Board Config Type Slot ...

Page 2: ...nce importantes qui se trouvent dans la documentation fournie avec le matériel Pour en savoir plus sur les règles de sécurité la conformité à la réglementation la compatibilité EMI EMF l accessibilité et autres sujets connexes lisez les informations de sécurité et de conformité Extron réf 68 290 01 sur le site Extron www extron com Istruzioni di sicurezza Italiano AVVERTENZA Il simbolo se usato su...

Page 3: ...ression Codec Connect DDSP Digital Display Sync Processing DMI Dynamic Motion Interpolation Driver Configurator DSP Configurator DSVP Digital Sync Validation Processing EQIP Everlast FastBite Flex55 FOX FOXBOX IP Intercom HelpDesk MAAP MicroDigital Opti Torque PendantConnect ProDSP QS FPC QuickSwitch Front Panel Controller Room Agent Scope Trigger SIS Simple Instruction Set Skew Free SpeedNav Trip...

Page 4: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference This interference must be corrected at the expense of the user NOTE For more information on safety guidelines regulatory compliances EMI EMF compat...

Page 5: ...computer or device responses mentioned in this guide the character 0 is used for the number zero and O represents the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here Reply from 208 132 180 48 bytes 32 times 2ms TTL 32 C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH R Data STX...

Page 6: ......

Page 7: ...io 17 Advanced 17 FPC 6000 Web Page 19 FPC 6000 Web Page 19 Updating the Firmware 20 Downloading Firmware 20 Updating Firmware Using the Touchpanel Web Page 21 Operation 22 Login Screen 22 Ties Screen 24 Menu Buttons 25 Input Buttons 25 Output Buttons 25 Audio Button 26 Mute Unmute Button 26 Select All 26 Take 26 Break 26 Clear Selection 26 Create a Tie 27 Break A Tie 28 Presets 30 Status Screen 3...

Page 8: ...FPC 6000 Contents viii ...

Page 9: ... FPC 6000 continues to support the following matrices FOX Matrix 3200 FOX Matrix 7200 FOX Matrix 14400 FOX Matrix 320X 1K Matrix systems multi FOX 320X with Mediator NOTE Additional matrix switchers will be added in the future See www extron com for the most recent information about compatible matrix switchers Features Intuitive menu driven 15 color touchscreen control interface Global presets FOX...

Page 10: ...IN 8 OUT IN 4 OUT IN FOX3 MATRIX 8io 5 OUT IN 1 OUT IN 6 OUT IN 2 OUT IN 7 OUT IN 3 OUT IN 8 OUT IN 4 OUT IN FOX3 MATRIX 8io 5 OUT IN 1 OUT IN 6 OUT IN 2 OUT IN 7 OUT IN 3 OUT IN 8 OUT IN 4 OUT IN FOX3 MATRIX 8io 5 OUT IN 1 OUT IN 6 OUT IN 2 OUT IN 7 OUT IN 3 OUT IN 8 OUT IN 4 OUT IN FOX3 MATRIX 8io 5 OUT IN 1 OUT IN 6 OUT IN 2 OUT IN 7 OUT IN 3 OUT IN 8 OUT IN 4 OUT IN FOX3 MATRIX 8io 5 OUT IN 1 ...

Page 11: ...memory it becomes the current configuration Room preset A configuration consisting of virtual outputs in a single room that has been stored When a room preset is retrieved from memory it becomes the current configuration FOX3 matrix supports up to 80 Room Presets and for each room up to 10 room presets are associated SFP Small form factor pluggable The SFP is an interface used in fiber optic conne...

Page 12: ...o change the password you must use the Extron Toolbelt utility see the Toolbelt Help File Talk to your Extron rep about obtaining a license for Toolbelt IP address for the matrix switcher Password for the matrix switcher See the user guide for your matrix switcher for information about the password 2 Decide where the FPC 6000 will be mounted see Mounting on page 6 3 Cable the unit If you are using...

Page 13: ...work Communication Use the Setup Menu see page 13 to set the DHCP status and if required the IP address subnet mask gateway and related settings for the FPC 6000 Test the connection to the switcher FPC 6000 Installation Overview 5 ...

Page 14: ...000 is housed in a rack mountable panel when it ships ATTENTION All structural steps and electrical installation must be performed by qualified personnel in accordance with local and national building codes and electrical codes Toute étape structurelle et installation électrique doit être effectuée par un personnel qualifié conformément aux codes du bâtiment aux codes incendie et sécurité et aux c...

Page 15: ...cuit overloading might have on overcurrent protection and supply wiring Give appropriate consideration to the equipment nameplate ratings when addressing this concern Reliable earthing grounding Maintain reliable grounding of rack mounted equipment Pay particular attention to supply connections other than direct connections to the branch circuit such as the use of power strips Wall Mounting the FP...

Page 16: ...ng plate to fit into 6 7 Hold the touchpanel at a slight angle and lower the notches at the top of the back panel over the hooks of the mounting plate 5 8 Swing the bottom of the touchpanel inwards so that it lies flat against the mounting plate with the flange at the bottom of the mounting plate sitting in a groove in the bottom of the touchpanel 6 9 Secure the touchpanel to the mounting plate wi...

Page 17: ... Sensor Monitors ambient light level and adjusts screen brightness D Capacitive Touch Screen The FPC 6000 has a 15 6 inch screen with 1366x768 resolution E Speakers Provide audible feedback from button presses F Motion Sensor Detects motion in front of the touchpanel G Menu Button Activates the setup menu and calibration screen see Setup Menu on page 13 It is accessed from under the touchpanel It ...

Page 18: ...ors I 12 VDC power supply input see page 12 E Audio Output J Mounting screws see page 12 A Reset LED Provides feedback about the reset status when the user presses the reset button see Reset Modes on page 36 B Reset Button Pressing the Reset button allows the unit to be reset in any of three different modes see Reset Modes C Menu Button Activates the setup menu and calibration screen see Setup Men...

Page 19: ...nformité réglementaire et peut endommager la source d alimentation ainsi que le produit final The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI NFPA 70 article 725 and the Canadian Electrical Code part 1 section 16 Cette installation doit toujours être en accord avec les mesures qui s applique au National Electrical Code ANSI NFPA 70 arti...

Page 20: ...ssées LPS Limited Power Source L utilisation d une source d alimentation non listée ou non listée LPS annulera toute certification de conformité réglementaire The length of the exposed wires in the stripping process is critical The ideal length is 3 16 inches 5 mm If they are any longer the exposed wires may touch causing a short circuit between them If they are any shorter the wires can be easily...

Page 21: ...17 Advanced see page 17 The screens are selected by pressing the appropriate button in the navigation panel at the top of the screen The button for the selected screen is yellow The buttons for the remaining screens are black There is also a red Exit button in the top right corner of the screen Pressing this button applies and saves any changes and closes the menu screens Status Press the Status b...

Page 22: ...e 8 Network Screen 1 If IP addresses are assigned by DHCP press On The selected button is highlighted in yellow When DHCP is off the Host Name button is grayed out and host name cannot be edited All addresses can be edited as shown in figure 8 When DHCP is on the host name can be edited The addresses are grayed out and cannot be edited because they are set by the DHCP server If IP addresses are as...

Page 23: ...pt to enter an invalid number for example 892 you are able to enter the 89 but the 2 cannot be entered Press Back to delete the last digit If no value has been entered for the selected octet pressing Back moves the cursor back to the previous octet e Press the next octet button and enter a value f Repeat steps c through e until values have been entered for all four octets g Press OK to save the ch...

Page 24: ...ed by the light sensor see figure 4 C on page 9 LCD Brightness Allows you to adjust the screen brightness using the slider control Wake on Motion Activates the panel from Sleep mode when motion is detected near the unit Toggle between On and Off Configuring the Motion Sensor The Motion Sensor see figure 4 F detects motion between three to five feet from the touchpanel and at least 15 from the cent...

Page 25: ...ent to only 80 percent of maximum Click Sets the volume for audible feedback that accompanies events such as a screen button being pressed Sound Sets the volume of audio from any audio file playback Click on the Speaker icon at the bottom of each panel to toggle between audio on and audio mute Advanced Press the Advanced button in the navigation panel at the top of the screen to open the Advanced ...

Page 26: ...e 14 Numeric Keypad for Setting PIN 2 Press a number on the keypad That number is masked by a dot 3 Repeat steps 1 and 2 for the other three digits 4 The title bar changes to Confirm New Menu Pin 5 Enter the PIN a second time When the PIN entered on the second occasion matches the PIN entered on the first occasion the PIN is set and the dialog closes 4 FPC 6000 Setup Menu 18 ...

Page 27: ...are case sensitive If the device is reset to default settings the password will be the default password configuration The default password is extron To change the password you must use the Extron Toolbelt utility see the Toolbelt Help File Talk to your Extron rep about obtaining a license for Toolbelt This page provides general and network information about the unit When logged in as a user the pa...

Page 28: ...gure 16 Firmware Download Center 4 The Firmware Download Center opens Click the letter F from the alphabet menu see figure 17 1 1 1 2 2 3 3 FPC 6000 Figure 17 Firmware Download Center 5 Scroll down the page until you find the firmware for the FPC 6000 6 Click Release Notes 2 for more information about the firmware optional 7 Click Download 3 8 Enter the required information in the form that opens ...

Page 29: ...pens navigate to the firmware location and select the file 5 Click Upload The firmware file is uploaded to the touchpanel The upload takes a few minutes A series of popup screens provide information about the progress of the firmware update Figure 19 Popup Screens from Firmware Update When the update is complete the FPC 6000 reboots and the login screen is shown You need to log in to the controlle...

Page 30: ... matrix switcher to be controlled from multiple locations This section of the guide describes the front panel login screen and how to use the four main screens Login Screen Ties Screen Status Screen I O Info Screen Customize Screen The login screen allows you to connect with a FOX matrix switcher over a LAN The other screens allow you to control and monitor the switcher Login Screen When the FPC 6...

Page 31: ...e available in the dropdown menu 5 Select the Matrix Type 4 using the dropdown if it is not set already 6 If required press the Password text box and use the on screen keyboard to enter the username by default this is admin and password for the matrix switcher NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords are case sensiti...

Page 32: ...t Input Input Input Input Input Input Input Input Input Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output TAKE MUTE UNMUTE VIDEO AUDIO VIDEO AUDIO USB A A A F F F B B B C C C D D D E E E G G G H H H I I I J J J K K K Figure 23 Ties Screen A Menu Buttons see the next page B Input Buttons see the next pa...

Page 33: ...C 6000 screen shows 20 inputs at a time Use the scroll bar to the right of the inputs to navigate through all the inputs that are available with your matrix switcher NOTES When selected the button lights up After 30 seconds with no front panel activity all buttons time out After 3 minutes with no front panel activity the panel enters power saving mode The touchpanel becomes active again when it de...

Page 34: ...e the audio and video the output button shows a diagonal line through the audio and video icons compare unmuted output 1 and muted output 2 in figure 26 Output 2 2 Output 1 1 Figure 26 Unmuted and Muted Outputs Select All To create potential ties from a selected input to all outputs press Select All J For the ties to go into effect press the Take button NOTE When you select an input and press Sele...

Page 35: ...ss one or more output buttons The selected output buttons light and a plus sign appears in the bottom right corner The Take button on the right of the screen becomes active as indicated by the orange band along the right edge of the button TIES I O INFO STATUS DISCONNECT CUSTOMIZE REFRESH OUTPUTS PRESETS SELECT ALL CLEAR SELECTION M AT R I X T I E S INPUTS Viewing Mode Grid Standard Grid Internal ...

Page 36: ... to break A minus sign appears in the bottom right corner of the selected output button and the Take button becomes active In figure 30 Input 186 has existing links to Outputs 115 121 and 128 Output 115 has been selected to break its tie with Input 186 as shown by the minus sign Outputs 121 and 128 have not been pressed and the ties remain TIES I O INFO STATUS DISCONNECT CUSTOMIZE REFRESH OUTPUTS ...

Page 37: ...al Audio Numpad Output 3 3 Output 1 1 Output 4 4 Output 7 7 Output 8 8 Output 5 5 Output 6 6 Output 11 11 Output 12 12 Output 9 9 Output 10 10 Output 14 14 Output 16 16 Output 13 13 Output 15 15 Output 18 18 Output 20 20 Output 17 17 Output 19 19 Output 2 2 Input 3 Input 1 Input 2 Input 4 Input 7 Input 8 Input 5 Input 6 Input 11 11 Input 12 12 Input 9 9 Input 10 10 Input 14 14 Input 16 16 Input 13...

Page 38: ...ther for the convenience of the operator Rooms and room presets can be recalled but cannot be created with the FPC 6000 They must be created by SIS commands sent from a PC to the switcher see the user guide for your matrix switcher Depending on the model Extron matrix switchers can support up to 10 rooms Each room can have 1 to 16 virtual outputs Each room can have up to 10 presets A room preset c...

Page 39: ...d special characters NOTE If you do not name the preset the next available name from the series Preset 1 Preset 2 etc is automatically assigned 6 Press Submit on the keyboard or Save Preset in the SAVING PRESET menu The preset is saved Overwriting an Existing Preset To overwrite an existing preset follow these instructions 1 Create one or more sets of ties and open the SAVING PRESET menu as descri...

Page 40: ... UNMUTE VIDEO AUDIO VIDEO AUDIO USB Output 3 3 Output 1 1 Output 4 4 Output 7 7 Output 8 8 Output 5 5 Output 6 6 Output 11 11 Output 12 12 Output 9 9 Output 10 10 Output 14 14 Output 16 16 Output 13 13 Output 18 18 Output 20 20 Output 17 17 Output 19 19 Output 2 2 Output 15 15 RECALLING PRESET PRESET TYPE Global Room 1 2 3 4 5 6 7 8 9 10 11 12 SPECIAL GLOBAL PRESET 12345 unassigned unassigned unas...

Page 41: ...esired room The selected room is shown at the top of the column and the presets that are available for that room are listed beneath NOTE Ten presets are available for each room TIES I O INFO STATUS DISCONNECT CUSTOMIZE REFRESH OUTPUTS PRESETS SELECT ALL CLEAR SELECTION M AT R I X T I E S INPUTS Viewing Mode Grid Standard Grid Internal Audio Numpad Viewing Mode Grid Standard Grid Internal Audio Num...

Page 42: ...tput Press I O Info in the menu bar on the left of the screen The I O Info screen opens with the Inputs tab selected To select outputs press the OUTPUTS button on the right side of the screen TIES I O INFO STATUS DISCONNECT CUSTOMIZE REFRESH INPUT Grid Standard Numpad Input 15 15 Input 13 13 Input 14 14 Input 16 16 Input 19 19 Input 20 20 Input 17 17 Input 18 18 Input 23 23 Input 24 24 Input 21 21...

Page 43: ...t 199 199 Output 111 111 Output 109 109 Output 112 112 Output 115 115 Output 116 116 Output 113 113 Output 114 114 Output 119 119 Output 120 120 Output 117 117 Output 118 118 Output 123 123 Output 124 124 Output 126 126 Output 128 128 Output 125 125 Output 127 127 Output 110 110 Output 122 122 Output 121 121 Medium Theme TIES I O INFO STATUS DISCONNECT CUSTOMIZE REFRESH OUTPUTS PRESETS SELECT ALL ...

Page 44: ...ng it The touchpanel enters factory firmware mode 3 Upload new firmware to the unit as desired see Updating Firmware Using the Touchpanel Web Page on page 21 NOTE Do not continue to operate the touchpanel using the factory firmware version If you want to use the factory default firmware you must upload that version again Result The unit reverts to factory installed firmware Event scripting does no...

Page 45: ... the Setup menu see page 14 to reset the IP address Once the IP address has been reset use a PC to open the FPC 6000 web page and reinstall the latest firmware see Updating Firmware Using the Touchpanel Web Page on page 21 Once the firmware is installed the FPC 6000 functions normally Reset to Factory Defaults This mode resets all IP settings and touchpanel settings to factory defaults and removes...

Page 46: ...n the FPC 6000 web page and reinstall the latest firmware see Updating Firmware Using the Touchpanel Web Page on page 21 Once the firmware is installed the FPC 6000 functions normally Enable or Disable the DHCP Client This mode toggles between DHCP enabled and DHCP disabled This can also be carried out from the Network screen of the see Setup Menu on page 13 Activation To enable or disable the DHC...

Page 47: ... not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron NOTE If a product is defective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 or ...

Reviews: