3
D
Menu and Enter buttons
— Press these buttons to access and navigate the on-screen display menu system.
E
Navigation buttons
— Press these buttons to navigate through the on-screen display menu system or change settings.
Reset
Press the rear panel recessed reset button (see
,
on page 1) if the FOX3 scaling receiver firmware is corrupted
or the unit gets disconnected during the update process. The different resets allow the device to revert to the factory loaded
firmware, reset IP seetings, or reset configuration to default (see the Reset Modes table, for details on the reset modes).
Reset Modes
Mode
Activation
Result
Purpose and Notes
Use Factory
Firmwar
e
1
Hold in the recessed rear panel
Reset
button while applying power
to the unit.
The unit reverts to the factory default
firmware for a single power cycle.
Use to revert to the factory default
firmware for a single power cycle if
incompatibility issues arise with user-
loaded firmware. All user files and settings
are maintained.
NOTE:
Do not operate with the default firmware loaded by a mode 1 reset. Use it only to load the most current
firmware to the device.
Reset IP Setting
*4
Hold in the
Reset
button about
6 seconds until the
Power
LED
blinks twice. Then, release
and press the
Reset
button
momentarily (<1 second) again
within 1 second.
Sets the following back to factory default:
•
Port mapping
•
IP address:
192.168.254.254
•
Subnet mask address:
255.255.255.0
•
Gateway address:
0.0.0.0
Turns DHCP off.
Power
LED blinks 4 times during reset.
Use to reset all IP settings back to the
factory defaults.
Equivalent to SIS command
1Z
QQQ.
Reset to Factory
Default
*5
Hold in the
Reset
button until
the
Power
LED blinks three times
(once at 3 seconds, again at
6 seconds, again at 9 seconds).
Then, release and press the
Reset
button again within 1 second
*
.
A complete reset to factory defaults
(except the firmware).
•
Does everything mode 4 does.
•
Clears port configurations.
•
Resets all IP options.
•
Clears all user settings.
•
Clears all files from the unit.
•
Power
LED blinks four times.
Use to start over with default configuration
and uploading, and also to replace events.
Equivalent to SIS command
Z
QQQ.
NOTES:
•
*For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.
•
The factory configured passwords for all accounts on this device have been set to the device serial number. In the
event of a complete system reset, the passwords convert to the default, which is
extron
.
Front Panel Lockout Mode (Executive Mode)
The front panel lockout mode limits operation of the device from the front panel. When enabled, use SIS commands or the
Product Configuration Software (PCS) to configure the device. To enable or disable the front panel lockout mode through the front
panel, press and hold the
Menu
,
) buttons simultaneously for 5 seconds or
until the power LED blinks.