3-7
IPL T S Series • Connection and Configuration
Figure 3-6 — Web server System Settings screen
To return the local PC to its original TCP/IP settings:
1
. Close the Web browser.
2
. Disconnect the Ethernet crossover cable from the PC and the device.
3
. Return to the TCP/IP Properties dialog box on the PC.
4
. Return the IP address, Subnet mask, Default gateway, and DHCP fields to
their original settings.
5
.
Reboot the PC.
Setting the IP address using the ARP command
An IPL T S unit’s IP address can be set using the DOS Address Resolution Protocol
(ARP) command.
The IPL T S unit must be:
• physically connected to the network
• at its factory default IP address
To set an IP address using the ARP command:
1
. Open a command prompt window on a local PC. On Windows XP, a
command prompt window can be found at:
Start > All Programs > Accessories > Command Prompt
2
. At the command prompt type:
arp - s<IP address><MAC address>
example: C:\>
arp -s 10.13.197.64 00-05-A6-00-30-5F
The example command assigns IP address 10.13.197.64 to the device that has
a MAC address of 00-05-A6-00-30-5F.