background image

1

Product Category

eBUS

®

 Button Panel Decorator-Style Series • Setup Guide

Overview

Extron offers a range of eBUS Button Panels (EBPs) in the decorator-style form factor that can be mounted in walls or furniture 
in any standard US 1-gang opening.  Each panel is a fully customizable AV system control interface for use with Extron IPCP Pro 
Series control processors. Individual EBPs are easily configured and can be connected with other panels to provide control for 
large and complex AV systems.

NOTE:

  These products are only for use with Extron UL Listed IPCP Pro control processors.

Each EBP button panel has two eBUS ports that support power and communications between the IPCP Pro control processor 
and eBUS devices. Up to eight eBUS devices such as EBP button panels can be connected to the control processor and to each 
other in various cabling topologies. Cabling topology refers to the physical layout of cabling interconnections between devices 
in a network such as an eBUS system. eBUS systems can include daisy chain, star, or hybrid (a combination of both) system 
topologies (see the 

eBUS Technology Reference Guide

, available on 

www.extron.com

for basic diagrams). Every device must 

have a unique identification address (eBUS ID) within the system.
Setup involves setting eBUS ID DIP switches on the EBPs, then using Extron Global Configurator

®

 Plus and Professional 

software, the Toolbelt utility, or Global Scripter

®

 programming software, to configure the control processor. Once configured, the 

AV system can be controlled from any of its EBPs.
This guide provides basic instructions for an experienced installer to install the EBP decorator-style series button panels. 
For more details on the EBPs, see the 

eBUS Technology Reference Guide

, available on 

www.extron.com

. For details on 

configuration or programming, see the software help files.

EBP Rear and Side Panel Features

Figure 1 shows the side and rear views of the EBP 105 D and the rear view of the EBP 103 D. The EBP 105 D side features are 
very similar for all EBP decorator-style models except the EBP 103 D. The EBP 105 D rear features are the same for all EBP 
decorator-style models except the EBP 103 D.

+V

eBUS

PWR  LOAD = 1.5W

+S

-S

G

+V

+S

-S

G

A

A

B

B

EBP 105 D Rear View

PWR LOAD = X.XW

LINK

CO

M

ERRO

R

ID

ERRO

R

+V   +S   -S   

G+

V   +S   -S   

G

eBUS

STATUS

EBP 103 D Rear View

A

A

B

B

EBP 103 D Side View

C

C

D

D

EBP 105 D Side View

D

D

C

C

Figure 1. 

EBP 105 D and EBP 103 D Rear and Side Views.

A

 

eBUS connectors

 (2 ports) — The four-pole captive screw connectors use the Extron eBUS protocol to connect the panel to 

a controller and to other panels (see 

Step 5: Cable All Devices

 on page 9).

B

 

Status LEDs

 — Provide diagnostic information about the connection, communication, and power status of the panels.

 

z

The EBP 103 D has amber, red, and green LEDs.

 

z

All other EBP decorator-style models have a single green LED.

For more information about how the LEDs are used for troubleshooting, see 

Step 7: Test and Troubleshoot

 on page 11.

C

 

DIP switches

 — Up to eight devices can be connected to one control processor. Each device connected to the same control 

processor must have a unique eBUS ID, which is set using DIP switches (see 

Step 4: Set the eBUS ID

 on page 6).

D

 

Reset button

 — Resets the firmware to the factory installed version (see 

To reset the firmware

 on the next page).

figure 1

Summary of Contents for eBUS 110 D

Page 1: ...uide provides basic instructions for an experienced installer to install the EBP decorator style series button panels For more details on the EBPs see the eBUS Technology Reference Guide available on www extron com For details on configuration or programming see the software help files EBP Rear and Side Panel Features Figure 1 shows the side and rear views of the EBP 105 D and the rear view of the...

Page 2: ...VIDEO PC LAPTOP ON OFF EBP 110 D B B B B C C EBP 106P D EBP 106P D DISPLAY OFF ON PC LAPTOP VIDEO DOC CAM A A B B C C D D D D DISPLAY ON OFF PC VIDEO LAPTOP MUTE EBP 108 D A A B B C C D D VIDEO PC VOLUME DISPLAY OFF ON EBP 106 D A A B B C C D D E E VOLUME E E E E F F G G H H D D E E G G E E SOURCE 1 SOURCE 2 SOURCE 3 EBP 103 D A A A VOLUME MICROPHONE A A G G E E Figure 3 EBP Decorator style Series...

Page 3: ...tional and local building and electrical codes that apply to the installation site Respectez tous les codes électriques et du bâtiment nationaux et locaux qui s appliquent au site de l installation NOTE For the installation to meet UL requirements and to comply with National Electrical Code NEC the EBP must be installed in a UL Listed junction box not included with the EBP The end user or installe...

Page 4: ... V O L U M E M U T E 1 3 Turn the rotary encoder to expose the screw Use an Allen wrench to loosen the screw 2 Figure 4 Removing the Rotary Encoder EBP VC1 D only Frame EBP 106 D Bezel Module 1 1 2 2 Figure 5 Releasing the Faceplate Replace buttons for panels except the EBP 103 D This section applies to all EBP decorator models except the EBP 103 D see Replace button labels for the EBP 103 D on th...

Page 5: ...l insert from the button cap TIP If the insert does not come out easily use a piece of sticky tape to pull it out of the button cap 4 Select one of the button labels from the printed label sheets included with the unit Remove the label from its backing and remove the clear protective film from the label 5 Insert the button label into the button cap 2 6 Align the cap with the white diffuser and pre...

Page 6: ...2 4 Off 22 4 3 Off 23 8 6 Off 20 1 Slide 1 2 3 4 5 6 ON M S B L S B BUS ID Figure 9 eBUS ID Setup Add the decimal numbers for each of the DIP switches that are set to On to obtain the address of the device In figure 9 only DIP switch 5 is on and the rest are off which means the address for the device in figure 9 is 0 0 0 0 2 0 2 NOTES Any address can be used except address 0 binary 000000 which is...

Page 7: ...3 4 5 6 ON M S B L S B 0 0 0 1 0 0 4 1 2 3 4 5 6 ON M S B L S B 0 1 0 0 1 1 19 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 0 1 5 1 2 3 4 5 6 ON M S B L S B 0 1 0 1 0 0 20 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 1 0 6 1 2 3 4 5 6 ON M S B L S B 0 1 0 1 0 1 21 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 1 1 7 1 2 3 4 5 6 ON M S B L S B 0 1 0 1 1 0 22 1 2 3 4 5 6 ON M S B L S B 0 0 1 0 0 0 8 1 2 3 4 5 6 ON M S B L S B 0 1 ...

Page 8: ...0 1 0 0 36 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 0 1 53 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 0 1 37 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 1 0 54 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 1 0 38 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 1 1 55 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 1 1 39 1 2 3 4 5 6 ON M S B L S B 1 1 1 0 0 0 56 1 2 3 4 5 6 ON M S B L S B 1 0 1 0 0 0 40 1 2 3 4 5 6 ON M S B L S B 1 1 1 0 0 1 57 1 2 3 4 5 6...

Page 9: ...source by disconnecting the V pin appropriately see figure 11 on the following page ATTENTION Always use a power supply supplied or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product Utilisez toujours une source d alimentation fournie ou recommandée par Extron L utilisation d une source d alim...

Page 10: ...or by an additional power supply 3 16 5 mm Max Ground Signal 12 VDC Signal Ground Signal Signal X X Tie drain wires to ground eBUS 24 WATTS MAX 100 240V 50 60Hz 0 6A MAX S V S G S V S G S V S G S V S G S V S G S V S G EBP V S G S V S G S eBUS Figure 11 Cabling an eBUS System with an PS 1220EB Power Supply and Distribution Hub Tie drain wires to ground Ridged Smooth 3 16 5 mm Max Ground Signal Sign...

Page 11: ...are both confirmed All other decorator style panels have a single green LED that provides information as follows z z Off The device is not receiving power z z Slow blink 1 blink per second The device is receiving power but communication with the control processor is not confirmed z z Fast blink 2 blinks per second There is an eBUS ID address conflict z z Lights solidly Power and communication are ...

Page 12: ...or style panels and has a front panel rotary encoder that protrudes from the wall more than the buttons of the other models Allow at least 1 44 inches 37 mm depth in the wall or furniture for cables The EBP VC1 D front panel including the rotary encoder extends 0 77 inches 20 mm from the wall 2 If required install an electrical junction box by following the instructions provided by the manufacture...

Page 13: ...ical Junction Box Figure 14 Mounting with a UL Listed Electrical Junction Box Removing Decorator Style EBPs If you need to remove a decorator style EBP from where it has been mounted follow these steps 1 Remove the two screws holding the frame to the module see figure 13 1 2 Remove the two screws holding the module to the junction box or wall mounting bracket 2 3 Remove the unit from the wall 3 an...

Page 14: ...18 Extron Electronics All rights reserved All trademarks mentioned are the property of their respective owners www extron com eBUS Button Panel Decorator Style Series Setup Guide Continued 68 1449 50 Rev D 03 18 ...

Reviews: