6
eBUS Button Panel Decorator-Style Series • Setup Guide (Continued)
Step 4: Set the eBUS ID
Up to eight devices can be connected to one control processor. In order for
the control processor to be successfully configured, each device connected to
the same control processor must have a unique six-bit, eBUS ID, which is set
with the DIP switch assembly on the side panel of the EBP (figure 8,
1
). If two
or more modules have the same eBUS ID, address conflicts may cause one or
more of the panels to not be recognized by the IPCP Pro control processor.
Various combinations of the six DIP switches being set to On or Off, provide 64
addresses: 0 is a reserved eBUS ID and the configurable eBUS ID range is 1
through 63 (see the table on the two following pages). The section below shows
an example of binary to decimal conversion.
1
1
Figure 8.
Decorator-style eBUS
Panel DIP Switches
eBUS ID Setup
Dip Switch
Position
Decimal
Off
1
2
5
=32
2
Off
2
4
=16
5
On
2
1
=2
4
Off
2
2
=4
3
Off
2
3
=8
6
Off
2
0
=1
Slide
1 2 3 4 5 6
ON
M
S
B
L
S
B
BUS ID
Figure 9.
eBUS ID Setup
Add the decimal numbers for each of the DIP switches that are set to
On
to obtain the address of the device. In figure 9, only DIP
switch 5 is on and the rest are off, which means the address for the device in figure 9 is 0+0+0+0+2+0 = 2.
NOTES:
•
Any address can be used except address 0 (binary: 000000), which is reserved (as the address of the controller) and
may not be used.
•
Switch 1 (on the left) is the highest value (32, the most significant bit) and is labelled
MSB
.
•
Switch 6 (on the right) is the lowest value (1, the least significant bit) and is labelled
LSB
.
•
Up
= on =
1
,
Down
= off =
0
The following table shows the factory default eBUS IDs and the corresponding addresses for the decorator-style models. These
IDs can be changed to any valid value.
Model
Address
eBUS ID
EBP 103 D
23
010111
EBP 105 D
2
000010
EBP 106 D
1
000001
EBP 106P D
13
001101
EBP 108 D
7
000111
EBP 110 D
8
001000
EBP 111 D
9
001001
EBP NAV D
18
010010
EBP VC1 D
17
010001
EBP VC2 D
15
001111
The table on the following two pages shows the DIP switch settings for all 64 possible addresses.