background image

 

3

Product Category

Planning the System and Installation

When planning to install an eBUS system, consider how many EBP button panels to use, maximum cable distance, cabling 
topology, and mounting. See the 

eBUS Technology Reference Guide

 for more information about eBUS topologies.

Installation

Step 1: Get Ready

Use the following check list to prepare for the installation.

 

†

Download and install the latest versions of the software, firmware, and device drivers needed to configure or program the 
IPCP Pro to control the connected AV products. See the 

IPCP Pro Series User Guide

 (available at 

www.extron.com

) for 

details on software and drivers.

 

†

Obtain network information (IP addresses, passwords, DHCP settings, and the like) and the MAC address for the control 
processor.

 

†

Obtain model names, drivers, and setup information for AV devices.

 

†

Determine which eBUS cabling topologies to use and obtain cables, mounting hardware, and any power supplies or 
hubs required by that configuration.

Step 2: Prepare the Installation Site

ATTENTION:

 

• 

Installation and service must be performed by authorized personnel only.

• 

L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.

• 

Extron recommends installing the EBP into a grounded, UL Listed electrical junction box.

• 

Extron recommande d’installer le EBP dans un boîtier d’encastrement électrique mis à la terre, listé UL.

• 

If the EBP will be installed into fine furniture, it is best to hire a licensed, bonded craftsperson to cut the access hole 
and perform the physical installation so the surface will not be damaged.

• 

S’il est prévu d’installer le EBP dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et qualifié 
pour couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.

• 

Follow all national and local building and electrical codes that apply to the installation site.

• 

Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.

NOTE:

  For the installation to meet UL requirements and to comply with National Electrical Code (NEC), the EBP must be 

installed in a UL Listed junction box (not included with the EBP). The end user or installer must furnish the junction box.

Americans with Disabilities Act (ADA) compliance

When planning where to install these devices, you may need to consider factors affecting accessibility of the button panel such 
as height from the floor, distance from obstructions, and how far a user must reach to press the buttons. For guidelines, see 
sections 307 (“Protruding Objects”) and 308 (“Reach Ranges”) of the 

2010 ADA Standards for Accessible Design

 available at 

http://www.ada.gov/regs2010/2010ADAStandards/2010ADAStandards.pdf

.

Site preparation

All of the EBP decorator-style series models, except the EBP 111 D, fit any standard 1-gang US wall opening. The EBP 111 D fits 
any standard 2-gang US wall opening. All devices ship with a mud ring of the correct size. In addition, Extron offers an assortment 
of optional UL Listed in-wall junction boxes, external wall boxes (EWBs), and surface or tabletop mounting boxes that can be 
used with the eBUS button panels (see 

www.extron.com

).

Step 3: Change the Buttons (Optional)

You can replace any combination of faceplate, buttons, or rotary encoder, depending on the model. You can order replacement or 
custom buttons using the Custom Button Builder at 

www.extron.com

.

To replace the buttons:

1. 

If required, remove the rotary encoder knob (EBP VC1 D only) (see 

Remove the rotary encoder knob

 on the next page).

2. 

Remove the wallplate (all models) (see 

To reset the firmware

 on the previous page).

3. 

Replace the buttons (all models except the EBP 103 D) (see 

Replace buttons for panels except the EBP 103 D

 on the next 

page).

4. 

Replace the button labels (EBP 103 D) (see 

Replace button labels for the EBP 103 D

 on page 5).

Summary of Contents for eBUS 110 D

Page 1: ...uide provides basic instructions for an experienced installer to install the EBP decorator style series button panels For more details on the EBPs see the eBUS Technology Reference Guide available on www extron com For details on configuration or programming see the software help files EBP Rear and Side Panel Features Figure 1 shows the side and rear views of the EBP 105 D and the rear view of the...

Page 2: ...VIDEO PC LAPTOP ON OFF EBP 110 D B B B B C C EBP 106P D EBP 106P D DISPLAY OFF ON PC LAPTOP VIDEO DOC CAM A A B B C C D D D D DISPLAY ON OFF PC VIDEO LAPTOP MUTE EBP 108 D A A B B C C D D VIDEO PC VOLUME DISPLAY OFF ON EBP 106 D A A B B C C D D E E VOLUME E E E E F F G G H H D D E E G G E E SOURCE 1 SOURCE 2 SOURCE 3 EBP 103 D A A A VOLUME MICROPHONE A A G G E E Figure 3 EBP Decorator style Series...

Page 3: ...tional and local building and electrical codes that apply to the installation site Respectez tous les codes électriques et du bâtiment nationaux et locaux qui s appliquent au site de l installation NOTE For the installation to meet UL requirements and to comply with National Electrical Code NEC the EBP must be installed in a UL Listed junction box not included with the EBP The end user or installe...

Page 4: ... V O L U M E M U T E 1 3 Turn the rotary encoder to expose the screw Use an Allen wrench to loosen the screw 2 Figure 4 Removing the Rotary Encoder EBP VC1 D only Frame EBP 106 D Bezel Module 1 1 2 2 Figure 5 Releasing the Faceplate Replace buttons for panels except the EBP 103 D This section applies to all EBP decorator models except the EBP 103 D see Replace button labels for the EBP 103 D on th...

Page 5: ...l insert from the button cap TIP If the insert does not come out easily use a piece of sticky tape to pull it out of the button cap 4 Select one of the button labels from the printed label sheets included with the unit Remove the label from its backing and remove the clear protective film from the label 5 Insert the button label into the button cap 2 6 Align the cap with the white diffuser and pre...

Page 6: ...2 4 Off 22 4 3 Off 23 8 6 Off 20 1 Slide 1 2 3 4 5 6 ON M S B L S B BUS ID Figure 9 eBUS ID Setup Add the decimal numbers for each of the DIP switches that are set to On to obtain the address of the device In figure 9 only DIP switch 5 is on and the rest are off which means the address for the device in figure 9 is 0 0 0 0 2 0 2 NOTES Any address can be used except address 0 binary 000000 which is...

Page 7: ...3 4 5 6 ON M S B L S B 0 0 0 1 0 0 4 1 2 3 4 5 6 ON M S B L S B 0 1 0 0 1 1 19 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 0 1 5 1 2 3 4 5 6 ON M S B L S B 0 1 0 1 0 0 20 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 1 0 6 1 2 3 4 5 6 ON M S B L S B 0 1 0 1 0 1 21 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 1 1 7 1 2 3 4 5 6 ON M S B L S B 0 1 0 1 1 0 22 1 2 3 4 5 6 ON M S B L S B 0 0 1 0 0 0 8 1 2 3 4 5 6 ON M S B L S B 0 1 ...

Page 8: ...0 1 0 0 36 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 0 1 53 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 0 1 37 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 1 0 54 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 1 0 38 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 1 1 55 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 1 1 39 1 2 3 4 5 6 ON M S B L S B 1 1 1 0 0 0 56 1 2 3 4 5 6 ON M S B L S B 1 0 1 0 0 0 40 1 2 3 4 5 6 ON M S B L S B 1 1 1 0 0 1 57 1 2 3 4 5 6...

Page 9: ...source by disconnecting the V pin appropriately see figure 11 on the following page ATTENTION Always use a power supply supplied or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product Utilisez toujours une source d alimentation fournie ou recommandée par Extron L utilisation d une source d alim...

Page 10: ...or by an additional power supply 3 16 5 mm Max Ground Signal 12 VDC Signal Ground Signal Signal X X Tie drain wires to ground eBUS 24 WATTS MAX 100 240V 50 60Hz 0 6A MAX S V S G S V S G S V S G S V S G S V S G S V S G EBP V S G S V S G S eBUS Figure 11 Cabling an eBUS System with an PS 1220EB Power Supply and Distribution Hub Tie drain wires to ground Ridged Smooth 3 16 5 mm Max Ground Signal Sign...

Page 11: ...are both confirmed All other decorator style panels have a single green LED that provides information as follows z z Off The device is not receiving power z z Slow blink 1 blink per second The device is receiving power but communication with the control processor is not confirmed z z Fast blink 2 blinks per second There is an eBUS ID address conflict z z Lights solidly Power and communication are ...

Page 12: ...or style panels and has a front panel rotary encoder that protrudes from the wall more than the buttons of the other models Allow at least 1 44 inches 37 mm depth in the wall or furniture for cables The EBP VC1 D front panel including the rotary encoder extends 0 77 inches 20 mm from the wall 2 If required install an electrical junction box by following the instructions provided by the manufacture...

Page 13: ...ical Junction Box Figure 14 Mounting with a UL Listed Electrical Junction Box Removing Decorator Style EBPs If you need to remove a decorator style EBP from where it has been mounted follow these steps 1 Remove the two screws holding the frame to the module see figure 13 1 2 Remove the two screws holding the module to the junction box or wall mounting bracket 2 3 Remove the unit from the wall 3 an...

Page 14: ...18 Extron Electronics All rights reserved All trademarks mentioned are the property of their respective owners www extron com eBUS Button Panel Decorator Style Series Setup Guide Continued 68 1449 50 Rev D 03 18 ...

Reviews: