Command
ASCII (T
elnet)
(host to pr
ocessor)
URL Encoded (W
eb)
(host to pr
ocessor)
Response
(pr
ocessor to host)
Additional description
Set unit name to factory
default
24
E
• CN
}
W%20CN
|
Ipn •
X4(
]
X4(
is the name the pr
ocessor was shipped
with: DVS304-##-##-##, a combination of
the model name and the last 3 pairs of hex
numbers in the pr
ocessor’
s MAC addr
ess
(for example, DVS304-00-02-3d).
Read unit name
E
CN
}
WCN
|
X1@
]
X1@
is the pr
ocessor’
s curr
ent unit name.
X4(
is its factory default name.
Set time/date
24
E
X1#
CT
}
W
X1#
CT
|
Ipt •
X1#
]
X1#
is local date and time format. The
set
format is MM/DD/YY
-HH:MM:SS.
Example:
11/18/03-10:54:00
Read time/date
E
CT
}
WCT
|
X1#
]
The
Read
format is
day of week DD month year
HH:MM:SS.
Example:
T
ue, 18 Nov 2008 18:19:33.
Set GMT of
fset
24
E
X#
CZ
}
W
X#
CZ
|
Ipz
X#
]
Set the Gr
eenwich Mean T
ime GMT) of
fset
value (
X#
) for the pr
ocessor’
s location.
GMT of
fset (-12.00 to +14.00) r
epr
esents the
time dif
fer
ence in hours and minutes
(± hh:mm r
elative to Gr
eenwich, England.
The plus sign and leading zer
o ar
e optional.
Example:
5:30 = +05:30.
Read GMT of
fset
E
CZ
} E
WCZ
|
X%
]
Set daylight saving time
24
E
X3$
CX
}
W
X3$
CX
|
Ipx
X3$
]
X3$
is the daylight savings time of day
.
Daylight savings time (DST) is a 1-hour of
fset
that is observed in the USA and parts of
Eur
ope and Brazil.
Read daylight saving time
E
CX
}
WCX
|
X3$
]
Set DHCP on
24
E
1DH
}
W1DH
|
Idh1
]
Set DHCP of
f
24
E
0DH
}
W0DH
|
Idh0
]
V
iew DHCP mode
E
DH
}
WDH
|
Idh
X%
]
X%
= 0 (of
f) or 1 (on).
NOTE:
X#
= Gr
eenwich Mean T
ime (GMT) of
fset value (-12:00 to 14:00) in hours and minutes (hh:mm)
X%
= On/Of
f 0 = of
f/disable, 1 = on/enable
X1@
= Name is a text string of up to 24 characters drawn fr
om the alphabet (A-Z), digits (0-9), and the minus sign/hyphen
(-). First character must be an alpha character
. Last character
must
not
be a minus. No blank or space characters ar
e permitted, and no distinction is made between upper and lower
case.
X1#
= Local date and time format
Set
format (MM/DD/YY
-HH:MM:SS); for example, 06/21/02-10:54:00.
Read
format (day of week, date month year (HH:MM:SS)),
for example, Thu, 20 Feb 2003 18:19:33
X3$
=
Daylight saving time (used in the norther
n hemispher
e [USA] and parts of Eur
ope and Brazil) 0 = of
f/ignor
e, 1 = on, 2 = Eur
ope, 3 = Brazil
X4(
=
Default name: a combination of the model name and the last 3 c
haracter pairs of the unit’
s MAC addr
ess (for example, DVS-304-00-023D)
DVS 304 Series • SIS Communication and Control
48