X3#
= Password (12 characters = maximum length; no special characters are allowed.)
NOTE:
A user password cannot be assigned if no administrator password exists; the
E14 error code is returned. If the administrator password is cleared, the user
password is also removed.
X3$
= Daylight saving time (used in the northern hemisphere [USA] and parts of Europe and Brazil),
0 = off/ignore, 1 = on, 2 = Europe, 3 = Brazil
X3%
= Event number, range: 0 - 99
X3^
= Event buffer: 0 = receive, 1 = unified, 2 = data, 3 = NVRAM
X3&
= Event buffer offset (range: 0 to MaxBufferSize)
X3*
= Event data size; b = bit, B = byte (8 bits), S = short (16 bits), L = long (32 bits)
NOTE:
This parameter is case sensitive.
X3(
= Event data to write
X4!
= Reading password: RS-232 connections responds with password. IP connections responds with
4 asterisk (****) if password exists and empty if not, instead of the actual password.
X4$
= Number of bytes to read (range = 1-24 max)
X4%
= E-mail event number (1 - 64 max). Response is returned as 2-digits with leading zeros.
X4^
= E-mail recipient’s address
X4&
= Name of e-mail file to be sent. First line is the subject, the rest is e-mail body.
NOTE:
The SM command will send a default e-mail message if file
X4&
is not found.
X4*
= Event status fields: event_type, event_state, event_paused, error_status, RcvBuff_startptr,
RcvBuff_endptr, DataBuffA_startptr, DataBuffA_endptr, DataBuffB_startptr, DataBuffB_startptr
X4(
= Default name: a combination of the model name and the last 3 character pairs of the unit’s
MAC address (for example, DVS-304-00-023D)
X5!
= Extended-security (Password) levels: 1 – 10. Response is 2 digits with a leading zero.
X5@
= Connection’s security level: 0 = anonymous, 1 – 10 = extended security levels 1 thru 10,
11 = user, 12 = administrator
X5$
= ASCII digit(s) representing the numeric value of the data element read from the
event buffer (leading zeros are suppressed)
X6)
= EDID file data block, 128 bytes of binary data
X6$
= Broadcast repetition rate in seconds, (0 – 255 max; default = 0 = clear)
The response is 2-digits returned with leading zeros. 1 – 11 = entry without password
goes to the level specified (if an admin password exists).
X6(
= The number of seconds before timeout on the IP connection: min. = 1; max. = 65000;
(default = 30 = 300 seconds). If no data is received during the timeout period, the
Ethernet connection is closed. Each step = 10 seconds. Applicable only when
connected via Ethernet. When connected via RS-232 only the global timeout
commands apply (current returns E13). Response is returned with leading zeros.
X7)
= Number (as optional parameter) that will get inserted into email message if .eml file
has an embedded server-side include “<!--#echo var=”WCR|”
-->
” (ESC CR command
with no params). Use 0 as placeholder if optional
X4&
is used but
X7)
isn’t needed.
X7!
= Input selection: 1 to 4
DVS 304 Series • SIS Communication and Control
34