DVI 201xi Tx • Installation
2-15
RS-232 signals
RS-232 signals are bidirectional – signals
pass from the control device and
replies return from the remote device.
To connect the control device to the
transmitter or the receiver to the remote
device, make the following connections:
Tx is connected to Tx.
•
Rx is connected to Rx.
•
Ground (
•
) is connected to ground.
N
For information about controlling display devices with
RS-232 commands, please refer to the user's manual of
that device.
IR signals
IR signals are one-way (from control device
to the IR emitter bug that will broadcast the
IR signal remotely). There are no responses
and no requirement for a reverse pathway.
To connect the control device to the
transmitter or the receiver to the IR emitter,
make the following connections:
The Signal (S), from the control device, is
•
connected to Tx of the transmitter.
The ground (G) of the control device is
•
connected to the ground ( ) of the transmitter.
The Tx of the receiver is connected to the S of the IR emitter.
•
The ground of the receiver is connected to the ground of the
•
IR emitter.
Tx Rx
CONTROL
PASS THRU
S G
DVI DL 201
Transmitter
or Receiver
IR Control
or IR emitter
Tx Rx
CONTROL
PASS THRU
Tx Rx
DVI DL 201
Transmitter
or Receiver
RS-232 Control
or Display Device
Summary of Contents for DVI 201xi TX
Page 1: ...User s Manual DVI 201xi Tx 68 1645 01 Rev A 12 08 Single Link DVI Transmitter...
Page 4: ......
Page 12: ...DVI 201xi Tx Introduction Introduction cont d 1 4...
Page 17: ...DVI 201xi Tx Installation 2 5...
Page 36: ...DVI 201xi Tx Configuration and Operation Configuration and Operation cont d 3 8...
Page 42: ...DVI 201xi Tx Reference Information Reference Information cont d A 6...