Extron DTP T HD2 4K 230/330 • Installation and Operation
4
UL Rack-Mounting Guidelines
The following Underwriters Laboratories (UL) requirements pertain to the installation of the
unit into a rack.
•
Elevated operating ambient temperature
— If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient. Therefore, consider installing the equipment in an environment
compatible with the maximum ambient temperature (TMA = +122 °F, +50 °C) specified
by Extron.
•
Reduced air flow
— Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
•
Mechanical loading
— Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
•
Circuit overloading
— Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might have
on overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
•
Reliable Earthing
— Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply a connection other than a
direct connection to a branch circuit, such as by using a power strip.
Front Panel Features
Extron
SIGNAL
HDCP
INPUT
2
OUTPUTS
LOOP
THRU
DTP T HD2 4K 330
CONFIG
A
B
C
D
A
Power status LED
— Lights green when power is applied to the unit.
B
USB Config port
— Used for firmware updates, SIS configuration, and software
control.
C
Input/Output signal LEDs
— Light green when HDCP presence is detected on the
HDMI input.
D
Input/Output HDCP LEDs
— Light green when HDCP presence is detected on the
HDMI outputs.