Extron DTP HD DA 4K Series • SIS Commands
11
SIS Commands
This section provides information about the SIS commands that are used to confi gure the
DTP HD DA 4K series. The following topics are discussed:
z
Introduction to SIS
z
Symbols Used in this Guide
z
DTP HD DA4 Series EDID Memory Locations
z
Command and Response Table for SIS Commands
Introduction to SIS
The distribution amplifi ers can be set up and controlled remotely via Extron SIS commands that
are issued from a host computer running the Extron DataViewer utility or other control system.
The host device can be connected to the RJ-45 LAN connector on the rear panel, the 3-pole
captive screw connector on the rear panel, or to the mini USB confi g port on the front panel.
The serial protocol is 9600 baud, 8 data bit, 1 stop bit, and no parity.
NOTE:
The wiring in the RS-232 cables crosses over so that the distribution amplifier
transmit (Tx) wire connects with the control device receive (Rx) and vice versa.
Host-to-Distribution Amplifier Communications
SIS commands consist of strings (one or more characters per command fi eld). No special
characters are required to begin or end a command sequence. Unless otherwise stated, upper
and lower case characters can be used interchangeably. Most responses from the distribution
amplifi er end with a carriage return and a line feed (CR/LF =
]
), which signal the end of the
response character string. When the switcher determines that a command is valid, it executes
the command and sends a response to the host device.
Distribution Amplifier-Initiated Messages
When a local event such as a change in signal status takes place, the distribution amplifi er
responds by sending a message to the host, indicating the status change. No response is
required from the host.
Copyright Information
The copyright message is displayed upon connecting to a DA via TCP/IP or Telnet or after a
power cycle via RS-232. An example is provided below.
]
(©) Copyright 20
yy
, Extron Electronics, DTP HD DA8 4K 330, V
x.xx
,
60-
xxxx
-01
]
Mon, 6 Feb 2017 11:27:33
]
20
yy
is the year the currently installed firmware was released,
V
x.xx
is the firmware version
number, and
60-
xxxx
-01
is the catalog part number.