background image

DVI 201 Tx/Rx • Installation and Operation

Installation and Operation, cont’d

2-10

DVI 201 Tx/Rx • Installation and Operation

 

2-11

6

Assemble the U-bolt and the following parts in the 

following order (figure 2-8):

a

.  Pass the legs of the U-bolt through the slotted holes on 

the mount plate flange.

b

.  Place the legs around the projector pole.

c

.  Pass the legs through the holes in the contour base.

N

 

The pole fits snugly into the depression in the 

center of the contoured base.

d

.  Pass the legs through the holes in the L-shaped bracket.

N

 

The supplied U-bolt fits a typical (1.5" to 2.0" 

diameter) ceiling pole.

U-bolt

Slotted Hole
in PMK Tray

L-shaped
Bracket

L-shaped
Bracket Screws

Contoured
Base

Ceiling
Pole

Mount Plate
Flange

Figure 2-8 — Hanging the tray on the pole

7

Align the two slotted holes in the bottom of the L-shaped 

bracket with the two slotted holes in the base of the tray.  

Secure the L-bracket to the base by inserting two provided 

6-32 x 5/16" screws through the aligned slots.

8

Move the PMK 350 up to the desired location on the ceiling 

pole, as close to the ceiling as desired.

9

Secure the L-shaped bracket to the U-bolt using the 

included hex nuts, washers, and lock washers.  Tighten the 

hex nuts securely.

N

 

Be sure to tighten the hex nuts securely enough that the 

PMK 350 does not slide down the ceiling pole.  A socket 

wrench is recommended to tighten the hex nuts.

10

.  Secure the front and rear plates to the mounting tray with 

four of the included #6 screws.

11

.  If desired, choose one of the provided four sizes of self-

adhesive cover sheets, and apply it to the underside of the 

mounting tray.

Decora unit mounting

The DVI 201 A D (Decora) transmitter and receiver can be 

installed in a one-gang electrical wall box with a Decora wall 

plate cover (supplied).
The installation must conform to national and local electrical 

codes and to the wall plate’s size requirements.

UL/Safety Requirements

The following Underwriters Laboratories (UL) requirements 

pertain to the installation of the Decora transmitters and 

receivers into a wall or furniture.

1

These units are not to be connected to a centralized DC 

power source or used beyond their rated voltage range.

2

These units must be installed in UL listed junction boxes.

3

These units must be installed with conduit in accordance 

with National Electrical Code.

Preparing the site and installing the wall box

Choose a location that allows cable runs without interference.  

Allow enough depth for both the wall box and the cables.  The 

box should be at least 2.5" (6.4 cm) deep to accommodate the 

connectors and cables.  Install the cables into the wall, furniture, 

or conduits before installing the wall plate.

N

 

The Decora units are very deep and have connectors 

on the back side (figure 2-9 on page 2-12).  Extron 

recommends its 1-gang or 2-gang junction boxes 

(part #s 

980130

 or 

980084

), which have a depth of 

2.5" (6.4 cm).

Summary of Contents for Digital Video Transmitter and Receiver DVI 201 Rx

Page 1: ...rope Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 400 883 1568 Inside Chi...

Page 2: ...den Stromunterbrechung Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der W...

Page 3: ...ection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in acc...

Page 4: ...jector mounting 2 6 Decora unit mounting 2 11 UL Safety Requirements 2 11 Preparing the site and installing the wall box 2 11 Final installation 2 14 Connections 2 15 Transmitter connections 2 15 Rece...

Page 5: ...s and Receivers Features 68 1034 02 Rev B 08 08 All trademarks mentioned in this manual are the properties of their respective owners Appendix A Reference Information A 1 Specifications A 2 Part Numbe...

Page 6: ...d as a pair of the same form factor or individually Each purchased pair and each individual transmitter is shipped with a single external desktop 12 VDC power supply that accepts 100 to 240 VAC 50 Hz...

Page 7: ...of cable used graphics card and display used in the system Features Transmits single link DVI D signals over two CAT 5 5e 6 cables Standard twisted pair cables provide an economical easily installed...

Page 8: ...Introduction cont d 1 6 DVI 201 Tx Rx 2 Chapter Two Installation and Operation Mounting the Tx Rx Connections Operation Technical Points for Digital Video and Content Protection Encryption Troublesho...

Page 9: ...ld be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of...

Page 10: ...furniture Mark the location of holes for screws on the desk 3 Drill 1 4 6 4 mm deep 3 32 2 mm diameter pilot holes in the table or desk at the marked screw locations from the underside or inside the c...

Page 11: ...place the unit inside the surface step 4 Projector mounting The receiver can be mounted on a projector bracket using either of the following optional Extron projector mounting kits PMK 300 multi produ...

Page 12: ...s mounting plate N The supplied U bolt fits a typical 1 5 to 2 0 diameter ceiling pole 6 Secure the bracket to the U bolt with the included hex nuts washers and lock washers Tighten the hex nuts just...

Page 13: ...rench is recommended to tighten the hex nuts 10 Secure the front and rear plates to the mounting tray with four of the included 6 screws 11 If desired choose one of the provided four sizes of self adh...

Page 14: ...Clamp Screws or Nails Signal Output Cable Figure 2 10 Installing the wall box N If attaching the wall box to wood use four 8 or 10 screws or 10 penny nails A minimum of 0 5 1 3 cm of screw thread must...

Page 15: ...ecora Faceplate Extron DVI 201 A D DV I AU DIO IN INPU T Tx Rx RS 232 PA SS TH RU Figure 2 11 Mounting the transmitter or receiver 3 At the power outlet reconnect the power supply This powers up both...

Page 16: ...d stereo audio source to this 3 5 mm mini stereo jack for unbalanced audio input Figure 2 14 shows how to wire the audio plug Tip L Sleeve Gnd Tip L Ring R Sleeve Gnd Figure 2 14 Audio input connector...

Page 17: ...nit such as a switcher an amplifier or a DVI 201 A D Rx Decora receiver Figure 2 15 shows how to wire the captive screw audio connector Insert the wires into the appropriate openings in the direct ins...

Page 18: ...nplug the connector on the unpowered end and connect the other cable to the 2 connector N Extron recommends 28AWG to 24AWG TP cable for the RJ 45 connectors See TP cable termination on page 2 23 to pr...

Page 19: ...EIA T 568B wiring standard for all connections Figure 2 20 details the recommended termination of TP cables with RJ 45 connectors in accordance with either the TIA EIA T 568A or the TIA EIA T 568B wi...

Page 20: ...ing Slightly overlap Cut and save the excess tape for other connectors Figure 2 22 Wrapping the shielded tape 4 Cut the unused portion of the shielded tape and retain for shielding other RJ 45 connect...

Page 21: ...shows how to wire the RS 232 connector for serial communications N The RS 232 connector can also transmit one way modulated infrared IR signals See Modulated IR pass through on page 2 33 Ground Receiv...

Page 22: ...P copyright decoding keys Receiver indicator N Both receiver models have power indicators in the same location as on the related transmitter model a Power LED DVI 201 Rx non Decora This front panel LE...

Page 23: ...The display may properly receive the digital video signal but not the HDCP key Without the key the display cannot decrypt the video signal Symptoms of undecrypted video may include a flashing black o...

Page 24: ...d to the Tx pin the modulated IR signal and the Gnd signal ground on the transmitter An IR emitter is connected to the Tx and Gnd receiver output Figure 2 28 Typical installation POWER 12V 0 4A MAX DV...

Page 25: ...DVI 201 Tx Rx Installation and Operation Installation and Operation cont d 2 34 DVI 201 Tx Rx A Appendix A Reference Information Specifications Part Numbers Decora Template Dimensions...

Page 26: ...UTP or STP Up to 200 60 m N The transmission distance varies greatly depending on the signal resolution and on the type of cable graphic card and display used in the system Video output receivers Numb...

Page 27: ...ely by receiver or transmitter on the other end of the CAT 5 5e 6 7 cable Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondens...

Page 28: ...01 IEC power cord 1 per power supply 3 5 mm 2 pole captive screw connector non Decora only 1 per unit 10 319 13 3 5 mm 3 pole captive screw connectors 1 per unit 10 319 15 Tweeker small screwdriver U...

Page 29: ...DM HDMI female to DVI D male adapter 26 616 01 HDMIM DVIDF HDMI male to DVI D female adapter 26 617 01 Decora Template Dimensions If you need to create a template use the dimensions shown on figure A...

Page 30: ...DVI 201 Tx Rx Reference Information Reference Information cont d A 10...