3
Preparing the Cable Cubby
Step 1 — Assemble the connectivity modules of your choice.
NOTE:
•
Use a screwdriver to secure the
Retractor trim with the screws.
•
After installing the retractor trim,
proceed to
Step 2 — Install the
modules
on the next page to
install the power module.
•
Retractors are installed after the
Cable Cubby is mounted on the
table (see
Installing Retractors
on page 5).
AAP Module
Cable
Pass-Through
Module
Retractor
Trim
Secure the retractor trim
using the provided
mounting screws (2).
Connectivity modules allow you to populate the Cable Cubby with a combination of AAPs, cable pass-through, or retractors.
NOTE:
After assembling the module,
proceed to
Step 2 — Install the
modules
on the next page.
NOTE:
After assembling the module,
proceed to
Step 2 — Install the
modules
on the next page.
Secure up to two
single-space AAPs
in the AAP plate.
#4-40 Nut
w/ Captive Washer
Insert cables through the bottom of the connectivity bracket.
Connect cables to the AAPs.
Secure the AAP plate on the connectivity brackets,
using two of the provided module screws.
1
2
3
Insert cables through the bottom of the connectivity bracket
and into the holes of the grommet plate.
Secure the grommet plate on the
connectivity bracket using two
of the provided module screws.
Snap the included hole plugs into
any unused holes.
1
2
3