Extron electronics 60-1252-13 User Manual Download Page 23

Mounting the USB Extender

CAUTION:

  Installation and service must be performed by authorized personnel only.

The three inch deep, one inch high, quarter rack width USB Extender transmitters and 

receivers can be placed on a tabletop, mounted on a rack shelf, or mounted under a desk 
or tabletop. The receiver can be mounted on a projector bracket. Consult the individual 
mounting kits for installation instructions.

Tabletop Placement

Affix the four included rubber feet to the bottom of the unit and place it in any convenient 
location.

Rack Mounting

UL Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation 

of these products in a rack:

1. 

Elevated operating ambient temperature — 

If the unit is installed in a closed or 

multi-unit rack assembly, the operating ambient temperature of the rack environment 
may be greater than room ambient temperature.  Therefore, install the equipment in 
an environment compatible with the maximum ambient temperature (Tma: +122 °F, 

+50 °C) specified by Extron.

2. 

Reduced air flow —

 Install the equipment in the rack so that the equipment gets 

adequate air flow for safe operation.

3. 

Mechanical loading —

 Mount the equipment in the rack so that uneven mechanical 

loading does not create a hazardous condition.

4. 

Circuit overloading —

 Connect the equipment to the supply circuit and consider the 

effect that circuit overloading might have on overcurrent protection and supply wiring.  
Consider the equipment nameplate ratings when addressing this concern.

5. 

Reliable earthing (grounding) —

 Maintain reliable grounding of rack-mounted 

equipment.  Pay particular attention to supply connections other than direct connections 
to the branch circuit (such as the use of power strips).For optional rack mounting, 
mount the transmitter or receiver on any of the following rack shelves:

Rack Mounting Procedure

The unit can be mounted on any of these optional rack systems, including:

• 

RSF 123

, Rack Shelf Kit for 3.5 inch deep products (part number 

60-190-20

)

• 

RSB 123

, Basic Rack Shelf for 3.5 inch deep products (part number 

60-604-21

)

• 

RSU 126

, Universal Rack Shelf for 6 inch deep products (part number 

60-190-11

)

• 

RSB 126

, Basic Rack Shelf for 6 inch deep products

 

(part number 

60-604-11

)

• 

RSU 129

, Universal Rack Shelf for 9.5 inch deep products (part number 

60-190-01

• 

RSB 129

, Basic Rack Shelf for 9.5 inch deep products, 

 

gray (part number 

60-604-02

)

To mount the USB Extender on a rack shelf, follow the instructions provided with the shelf 

accessories.

 

USB Extenders • Reference Information

17

Summary of Contents for 60-1252-13

Page 1: ...User Manual Twisted Pair Extender for USB Peripherals USB Extenders User Guide USB for Pro A V Series 68 1719 01 Rev B 12 11...

Page 2: ...machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Si...

Page 3: ...area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE This unit was tested with shielded cables on the peripheral dev...

Page 4: ...iv...

Page 5: ...ceiver Rear Panel 7 Operation 8 Transmitter Front Panel Indicators 8 Receiver Front Panel Indicators 9 Cabling and Setup 10 System Operation 12 Troubleshooting 12 Reference Information 13 Specificatio...

Page 6: ...USB Extenders Contents vi...

Page 7: ...l configure and operate the Extron Electronics USB Extender Tx Rx USB Extender AAP Tx Rx and the USB Extender D Decora Tx Rx transmitter and receiver Additional information can be found on the Extron...

Page 8: ...Extender system consists of a transmitter Tx and a receiver Rx The transmitter connects directly to a USB port on a PC or USB host The receiver features a four port USB hub to connect multiple periphe...

Page 9: ...y Included with each transmitter and each receiver USB Extender AAP and Decora Tx Rx The AAP and Decora versions have an RJ 45 rear connector in a single gang plate size enclosure Figure 2 USB Extende...

Page 10: ...Apply power to the USB extenders If external supplies are used with the transmitter and receiver both power LEDs and both LINK LEDs light to indicate proper link cable connection between the transmitt...

Page 11: ...tor bracket The USB Extender AAPs can be wall or floor mounted in two gang 2 5 inch deep boxes The Decora series can be mounted in a single gang 2 5 inch deep wall box Mounting details are included in...

Page 12: ...he Extron A V processing equipment in an ordinary location Pollution Degree 2 secured to the equipment rack within the dedicated closet podium or desk The installation must always be in accordance wit...

Page 13: ...C power supply into this 2 pole 3 5 mm captive screw connector e Link twisted pair connector Connect the TP cable from the transmitter Link connector figure 3 item c to this RJ 45 female connector CAU...

Page 14: ...e A male to mini Type B male USB cable between this port and the USB output port of a PC or laptop The USB Extender is USB 2 0 compliant and able to support data transfers of 480 Mbps high speed 12 Mb...

Page 15: ...female USB Type A connectors are used for the built in four port hub The connections are USB 2 0 compatible providing 5 VDC at up to 500 mA to connected USB peripherals requiring power j Power LED Li...

Page 16: ...smitter Receiver UTP or STP CAT5 or better cable Terminate both ends identically in accordance with either the TIA EIA T 568A or the TIA EIA T 568B wiring standard Figure 7 USB Extender Connection Gui...

Page 17: ...d power supply to the USB Extender receiver and apply power The Power LED on the receiver lights NOTE The transmitter Power LED and both Link LEDs remain dark 3 Connect a Type A B USB cable Type A mal...

Page 18: ...ransmitter and receiver Power LEDs Link LEDs and Host LEDs are lit The hub LED for each connected peripheral recognized by the host PC is also lit Front panel LEDs may also be useful for troubleshooti...

Page 19: ...P Tx USB Extender D Tx 1 female mini USB type B Interconnection between transmitter and receiver Connectors 1 female RJ 45 per unit Termination standards TIA 568A or TIA 568B Signal transmission dista...

Page 20: ...1 4 H x 2 5 W x 1 4 D 3 5 cm H x 6 4 cm W x 3 6 cm D Depth excludes connectors and pigtail Allow at least 1 6 4 1 cm depth in the wall or furniture USB Extender D Tx Rx Faceplate 2 6 H x 1 3 W x 0 1...

Page 21: ...Kit for 3 5 inch deep products 60 190 20 RSB 123 Basic Rack Shelf for 3 5 inch deep products 60 604 21 RSU 126 Universal Rack Shelf for 6 inch deep products 60 190 10 RSB 126 Basic Rack Shelf for 6 i...

Page 22: ...of TP cables with RJ 45 connectors NOTE Terminate both ends of a cable identically in accordance with either the TIA EIA T 568A or the TIA EIA T 568B wiring standard 12345678 Insert Twisted Pair Wire...

Page 23: ...nical loading Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition 4 Circuit overloading Connect the equipment to the supply circuit and consider the...

Page 24: ...xtron MBD 129 Through Desk Mounting Kit for quarter or half rack width products part number 70 077 02 To mount the USB Extenders follow the instructions provided with the mounting kit Projector Mounti...

Page 25: ...and install the wall box Choose a location that allows cable runs without interference Allow enough depth for both the wall box the TP cable and power supply wiring The box should be at least 2 5 inch...

Page 26: ...ion Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 Europe 31 33 453 4040 Asia 65 6383 4400 Japan 81 3 3511 7655 Units must be returned insure...

Reviews: