Table 193: Power Specifications
Switch Model
X690-48t-2q-4c
AC Input: 100-127 VAC, 4.0 A max. per PSU, 50/60 Hz
AC Input: 200-240 VAC, 2.0 A max. per PSU, 50/60 Hz
DC Input: -48 to 60 VDC, 8.0 A max. per PSU
X690-48x-2q-4c
AC Input: 100-127 VAC, 3.0 A max. per PSU, 50/60 Hz
AC Input: 200-240 VAC, 1.5 A max. per PSU, 50/60 Hz
DC Input: -48 to 60 VDC, 6.0 A max. per PSU
Table 194: X690 Power Consumption
Switch Model
Minimum Heat
Dissipation (BTU/hr)
Minimum Power
Consumption (W)
Maximum Heat
Dissipation (BTU/hr)
Maximum Power
Consumption
(W)
X690-48x-2q-4c AC
282 BTU/hr
83 W
1124 BTU/hr
329 W
X690-48x-2q-4c DC
311 BTU/hr
91 W
1178 BTU/hr
345 W
X690-48t-2q-4c AC
425 BTU/hr
125 W
1271 BTU/hr
373 W
X690-48t-2q-4c DC
421 BTU/hr
123 W
1315 BTU/hr
385 W
1 PSU
2 PSU
CPU, Memory
CPU/Memory
1 GHz 64-bit CPU
2 GB DDR3 ECC SDRA memory
4 GB eMMC Flash Memory
12 MB buffer, per chip
Standards and Environmental Data
Table 195: Safety Standards
North American Safety of ITE
UL 60950-1 1st Ed., Listed Device (US)
CSA 22.2 #60950-1-07 2nd Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
European Safety of ITE
EN 60950-1:2006 2nd Ed. TUV-R GS
EN 60825-1:2007 (Lasers Safety)
2006/95/EC Low Voltage Directive
International Safety of ITE
CB Report & Certificate per IEC 60950-1:2005 2nd Ed.,
+ National Differences
AS/NZX 60950-1 (Australia /New Zealand)
Technical Specifications
ExtremeSwitching and Summit Switches: Hardware Installation Guide
356